Filtered by vendor Rockwellautomation
Subscribe
Total
258 CVE
CVE | Vendors | Products | Updated | CVSS v2 | CVSS v3 |
---|---|---|---|---|---|
CVE-2020-6085 | 1 Rockwellautomation | 1 Flex I\/o 1794-aent | 2024-02-28 | 7.8 HIGH | 7.5 HIGH |
An exploitable denial of service vulnerability exists in the ENIP Request Path Logical Segment functionality of Allen-Bradley Flex IO 1794-AENT/B 4.003. A specially crafted network request can cause a loss of communications with the device resulting in denial-of-service. An attacker can send a malicious packet to trigger this vulnerability by sending an Electronic Key Segment with less than 0x18 bytes following the Key Format field. | |||||
CVE-2020-6083 | 1 Rockwellautomation | 2 Allen-bradley Flex Io 1794-aent\/b, Allen-bradley Flex Io 1794-aent\/b Firmware | 2024-02-28 | 5.0 MEDIUM | 7.5 HIGH |
An exploitable denial of service vulnerability exists in the ENIP Request Path Port Segment functionality of Allen-Bradley Flex IO 1794-AENT/B. A specially crafted network request can cause a loss of communications with the device resulting in denial-of-service. An attacker can send a malicious packet to trigger this vulnerability. | |||||
CVE-2021-22665 | 1 Rockwellautomation | 2 Drivetools Add-on Profiles, Drivetools Sp | 2024-02-28 | 7.2 HIGH | 7.8 HIGH |
Rockwell Automation DriveTools SP v5.13 and below and Drives AOP v4.12 and below both contain a vulnerability that a local attacker with limited privileges may be able to exploit resulting in privilege escalation and complete control of the system. | |||||
CVE-2020-27253 | 1 Rockwellautomation | 1 Factorytalk Linx | 2024-02-28 | 7.8 HIGH | 7.5 HIGH |
A flaw exists in the Ingress/Egress checks routine of FactoryTalk Linx Version 6.11 and prior. This vulnerability could allow a remote, unauthenticated attacker to specifically craft a malicious packet resulting in a denial-of-service condition on the device. | |||||
CVE-2020-6087 | 1 Rockwellautomation | 2 Flex I\/o 1794-aent\/b, Flex I\/o 1794-aent\/b Firmware | 2024-02-28 | 7.8 HIGH | 7.5 HIGH |
An exploitable denial of service vulnerability exists in the ENIP Request Path Data Segment functionality of Allen-Bradley Flex IO 1794-AENT/B. A specially crafted network request can cause a loss of communications with the device resulting in denial-of-service. An attacker can send a malicious packet to trigger this vulnerability If the ANSI Extended Symbol Segment Sub-Type is supplied, the device treats the byte following as the Data Size in words. When this value represents a size greater than what remains in the packet data, the device enters a fault state where communication with the device is lost and a physical power cycle is required. | |||||
CVE-2020-6086 | 1 Rockwellautomation | 2 Flex I\/o 1794-aent\/b, Flex I\/o 1794-aent\/b Firmware | 2024-02-28 | 7.8 HIGH | 7.5 HIGH |
An exploitable denial of service vulnerability exists in the ENIP Request Path Data Segment functionality of Allen-Bradley Flex IO 1794-AENT/B. A specially crafted network request can cause a loss of communications with the device resulting in denial-of-service. An attacker can send a malicious packet to trigger this vulnerability.If the Simple Segment Sub-Type is supplied, the device treats the byte following as the Data Size in words. When this value represents a size greater than what remains in the packet data, the device enters a fault state where communication with the device is lost and a physical power cycle is required. | |||||
CVE-2020-27267 | 4 Ge, Ptc, Rockwellautomation and 1 more | 7 Industrial Gateway Server, Kepware Kepserverex, Opc-aggregator and 4 more | 2024-02-28 | 6.4 MEDIUM | 9.1 CRITICAL |
KEPServerEX v6.0 to v6.9, ThingWorx Kepware Server v6.8 and v6.9, ThingWorx Industrial Connectivity (all versions), OPC-Aggregator (all versions), Rockwell Automation KEPServer Enterprise, GE Digital Industrial Gateway Server v7.68.804 and v7.66, and Software Toolbox TOP Server all 6.x versions, are vulnerable to a heap-based buffer overflow. Opening a specifically crafted OPC UA message could allow an attacker to crash the server and potentially leak data. | |||||
CVE-2021-22681 | 1 Rockwellautomation | 20 Compact Guardlogix 5370, Compact Guardlogix 5380, Compactlogix 1768 and 17 more | 2024-02-28 | 7.5 HIGH | 9.8 CRITICAL |
Rockwell Automation Studio 5000 Logix Designer Versions 21 and later, and RSLogix 5000 Versions 16 through 20 use a key to verify Logix controllers are communicating with Rockwell Automation CompactLogix 1768, 1769, 5370, 5380, 5480: ControlLogix 5550, 5560, 5570, 5580; DriveLogix 5560, 5730, 1794-L34; Compact GuardLogix 5370, 5380; GuardLogix 5570, 5580; SoftLogix 5800. Rockwell Automation Studio 5000 Logix Designer Versions 21 and later and RSLogix 5000: Versions 16 through 20 are vulnerable because an unauthenticated attacker could bypass this verification mechanism and authenticate with Rockwell Automation CompactLogix 1768, 1769, 5370, 5380, 5480: ControlLogix 5550, 5560, 5570, 5580; DriveLogix 5560, 5730, 1794-L34; Compact GuardLogix 5370, 5380; GuardLogix 5570, 5580; SoftLogix 5800. | |||||
CVE-2020-13573 | 1 Rockwellautomation | 1 Rslinx | 2024-02-28 | 5.0 MEDIUM | 7.5 HIGH |
A denial-of-service vulnerability exists in the Ethernet/IP server functionality of Rockwell Automation RSLinx Classic 2.57.00.14 CPR 9 SR 3. A specially crafted network request can lead to a denial of service. An attacker can send a sequence of malicious packets to trigger this vulnerability. | |||||
CVE-2021-22659 | 1 Rockwellautomation | 2 Micrologix 1400, Micrologix 1400 Firmware | 2024-02-28 | 7.5 HIGH | 8.6 HIGH |
Rockwell Automation MicroLogix 1400 Version 21.6 and below may allow a remote unauthenticated attacker to send a specially crafted Modbus packet allowing the attacker to retrieve or modify random values in the register. If successfully exploited, this may lead to a buffer overflow resulting in a denial-of-service condition. The FAULT LED will flash RED and communications may be lost. Recovery from denial-of-service condition requires the fault to be cleared by the user. | |||||
CVE-2020-5807 | 1 Rockwellautomation | 1 Factorytalk Diagnostics | 2024-02-28 | 5.0 MEDIUM | 7.5 HIGH |
An unauthenticated remote attacker can send data to RsvcHost.exe listening on TCP port 5241 to add entries in the FactoryTalk Diagnostics event log. The attacker can specify long fields in the log entry, which can cause an unhandled exception in wcscpy_s() if a local user opens FactoryTalk Diagnostics Viewer (FTDiagViewer.exe) to view the log entry. Observed in FactoryTalk Diagnostics 6.11. All versions of FactoryTalk Diagnostics are affected. | |||||
CVE-2020-27251 | 1 Rockwellautomation | 1 Factorytalk Linx | 2024-02-28 | 7.5 HIGH | 9.8 CRITICAL |
A heap overflow vulnerability exists within FactoryTalk Linx Version 6.11 and prior. This vulnerability could allow a remote, unauthenticated attacker to send malicious port ranges, which could result in remote code execution. | |||||
CVE-2020-5806 | 1 Rockwellautomation | 1 Factorytalk Linx | 2024-02-28 | 2.1 LOW | 5.5 MEDIUM |
An attacker-controlled memory allocation size can be passed to the C++ new operator in the CServerManager::HandleBrowseLoadIconStreamRequest in messaging.dll. This can be done by sending a specially crafted message to 127.0.0.1:7153. Observed in FactoryTalk Linx 6.11. All versions of FactoryTalk Linx are affected. | |||||
CVE-2020-27263 | 4 Ge, Ptc, Rockwellautomation and 1 more | 7 Industrial Gateway Server, Kepware Kepserverex, Opc-aggregator and 4 more | 2024-02-28 | 6.4 MEDIUM | 9.1 CRITICAL |
KEPServerEX: v6.0 to v6.9, ThingWorx Kepware Server: v6.8 and v6.9, ThingWorx Industrial Connectivity: All versions, OPC-Aggregator: All versions, Rockwell Automation KEPServer Enterprise, GE Digital Industrial Gateway Server: v7.68.804 and v7.66, Software Toolbox TOP Server: All 6.x versions, are vulnerable to a heap-based buffer overflow. Opening a specifically crafted OPC UA message could allow an attacker to crash the server and potentially leak data. | |||||
CVE-2020-6111 | 1 Rockwellautomation | 2 Micrologix 1100, Micrologix 1100 B Firmware | 2024-02-28 | 5.0 MEDIUM | 7.5 HIGH |
An exploitable denial-of-service vulnerability exists in the IPv4 functionality of Allen-Bradley MicroLogix 1100 Programmable Logic Controller Systems Series B FRN 16.000, Series B FRN 15.002, Series B FRN 15.000, Series B FRN 14.000, Series B FRN 13.000, Series B FRN 12.000, Series B FRN 11.000 and Series B FRN 10.000. A specially crafted packet can cause a major error, resulting in a denial of service. An attacker can send a malicious packet to trigger this vulnerability. | |||||
CVE-2020-6084 | 1 Rockwellautomation | 1 Flex I\/o 1794-aent | 2024-02-28 | 7.8 HIGH | 7.5 HIGH |
An exploitable denial of service vulnerability exists in the ENIP Request Path Logical Segment functionality of Allen-Bradley Flex IO 1794-AENT/B 4.003. A specially crafted network request can cause a loss of communications with the device resulting in denial-of-service. An attacker can send a malicious packet to trigger this vulnerability by sending an Electronic Key Segment with less bytes than required by the Key Format Table. | |||||
CVE-2020-27265 | 4 Ge, Ptc, Rockwellautomation and 1 more | 7 Industrial Gateway Server, Kepware Kepserverex, Opc-aggregator and 4 more | 2024-02-28 | 7.5 HIGH | 9.8 CRITICAL |
KEPServerEX: v6.0 to v6.9, ThingWorx Kepware Server: v6.8 and v6.9, ThingWorx Industrial Connectivity: All versions, OPC-Aggregator: All versions, Rockwell Automation KEPServer Enterprise, GE Digital Industrial Gateway Server: v7.68.804 and v7.66, Software Toolbox TOP Server: All 6.x versions are vulnerable to a stack-based buffer overflow. Opening a specifically crafted OPC UA message could allow an attacker to crash the server and remotely execute code. | |||||
CVE-2020-14516 | 1 Rockwellautomation | 1 Factorytalk Services Platform | 2024-02-28 | 7.5 HIGH | 10.0 CRITICAL |
In Rockwell Automation FactoryTalk Services Platform Versions 6.10.00 and 6.11.00, there is an issue with the implementation of the SHA-256 hashing algorithm with FactoryTalk Services Platform that prevents the user password from being hashed properly. | |||||
CVE-2020-5801 | 1 Rockwellautomation | 1 Factorytalk Linx | 2024-02-28 | 5.0 MEDIUM | 7.5 HIGH |
An attacker can craft and send an OpenNamespace message to port 4241 with valid session-id that triggers an unhandled exception in CFTLDManager::HandleRequest function in RnaDaSvr.dll, resulting in process termination. Observed in FactoryTalk Linx 6.11. All versions of FactoryTalk Linx are affected. | |||||
CVE-2020-6967 | 1 Rockwellautomation | 1 Factorytalk Services Platform | 2024-02-28 | 10.0 HIGH | 9.8 CRITICAL |
In Rockwell Automation all versions of FactoryTalk Diagnostics software, a subsystem of the FactoryTalk Services Platform, FactoryTalk Diagnostics exposes a .NET Remoting endpoint via RNADiagnosticsSrv.exe at TCPtcp/8082, which can insecurely deserialize untrusted data. |