Filtered by vendor Ge
Subscribe
Total
128 CVE
CVE | Vendors | Products | Updated | CVSS v2 | CVSS v3 |
---|---|---|---|---|---|
CVE-2017-7905 | 1 Ge | 20 Multilin Sr 369 Motor Protection Relay, Multilin Sr 369 Motor Protection Relay Firmware, Multilin Sr 469 Motor Protection Relay and 17 more | 2024-11-21 | 5.0 MEDIUM | 9.8 CRITICAL |
A Weak Cryptography for Passwords issue was discovered in General Electric (GE) Multilin SR 750 Feeder Protection Relay, firmware versions prior to Version 7.47; SR 760 Feeder Protection Relay, firmware versions prior to Version 7.47; SR 469 Motor Protection Relay, firmware versions prior to Version 5.23; SR 489 Generator Protection Relay, firmware versions prior to Version 4.06; SR 745 Transformer Protection Relay, firmware versions prior to Version 5.23; SR 369 Motor Protection Relay, all firmware versions; Multilin Universal Relay, firmware Version 6.0 and prior versions; and Multilin URplus (D90, C90, B95), all versions. Ciphertext versions of user passwords were created with a non-random initialization vector leaving them susceptible to dictionary attacks. Ciphertext of user passwords can be obtained from the front LCD panel of affected products and through issued Modbus commands. | |||||
CVE-2017-12732 | 1 Ge | 1 Intelligent Platforms Proficy Hmi\/scada Cimplicity | 2024-11-21 | 4.9 MEDIUM | 6.8 MEDIUM |
A Stack-based Buffer Overflow issue was discovered in GE CIMPLICITY Versions 9.0 and prior. A function reads a packet to indicate the next packet length. The next packet length is not verified, allowing a buffer overwrite that could lead to an arbitrary remote code execution. | |||||
CVE-2016-9360 | 1 Ge | 3 Cimplicity, Historian, Ifix | 2024-11-21 | 4.4 MEDIUM | 6.7 MEDIUM |
An issue was discovered in General Electric (GE) Proficy HMI/SCADA iFIX Version 5.8 SIM 13 and prior versions, Proficy HMI/SCADA CIMPLICITY Version 9.0 and prior versions, and Proficy Historian Version 6.0 and prior versions. An attacker may be able to retrieve user passwords if he or she has access to an authenticated session. | |||||
CVE-2016-5788 | 1 Ge | 4 Bently Nevada 3500\/22m Serial, Bently Nevada 3500\/22m Serial Firmware, Bently Nevada 3500\/22m Usb and 1 more | 2024-11-21 | 10.0 HIGH | 10.0 CRITICAL |
General Electric (GE) Bently Nevada 3500/22M USB with firmware before 5.0 and Bently Nevada 3500/22M Serial have open ports, which makes it easier for remote attackers to obtain privileged access via unspecified vectors. | |||||
CVE-2016-5787 | 1 Ge | 1 Cimplicity | 2024-11-21 | 4.6 MEDIUM | 6.3 MEDIUM |
General Electric (GE) Digital Proficy HMI/SCADA - CIMPLICITY before 8.2 SIM 27 mishandles service DACLs, which allows local users to modify a service configuration via unspecified vectors. | |||||
CVE-2016-2310 | 1 Ge | 8 Multilink Firmware, Multilink Ml1200, Multilink Ml1600 and 5 more | 2024-11-21 | 10.0 HIGH | 9.8 CRITICAL |
General Electric (GE) Multilink ML800, ML1200, ML1600, and ML2400 switches with firmware before 5.5.0 and ML810, ML3000, and ML3100 switches with firmware before 5.5.0k have hardcoded credentials, which allows remote attackers to modify configuration settings via the web interface. | |||||
CVE-2016-0862 | 1 Ge | 5 Snmp\/web Adapter 1024746, Snmp\/web Adapter 1024747, Snmp\/web Adapter 1024748 and 2 more | 2024-11-21 | 4.0 MEDIUM | 6.5 MEDIUM |
General Electric (GE) Industrial Solutions UPS SNMP/Web Adapter devices with firmware before 4.8 allow remote authenticated users to obtain sensitive cleartext account information via unspecified vectors. | |||||
CVE-2016-0861 | 1 Ge | 1 Ups Snmp Web Adapter Firmware | 2024-11-21 | 9.0 HIGH | 8.8 HIGH |
General Electric (GE) Industrial Solutions UPS SNMP/Web Adapter devices with firmware before 4.8 allow remote authenticated users to execute arbitrary commands via unspecified vectors. | |||||
CVE-2015-6459 | 1 Ge | 1 Mds Pulsenet | 2024-11-21 | 10.0 HIGH | N/A |
Absolute path traversal vulnerability in the download feature in FileDownloadServlet in GE Digital Energy MDS PulseNET and MDS PulseNET Enterprise before 3.1.5 allows remote attackers to read or delete arbitrary files via a full pathname. | |||||
CVE-2015-6456 | 1 Ge | 1 Mds Pulsenet | 2024-11-21 | 9.0 HIGH | N/A |
GE Digital Energy MDS PulseNET and MDS PulseNET Enterprise before 3.1.5 have hardcoded credentials for a support account, which allows remote attackers to obtain administrative access, and consequently execute arbitrary code, by leveraging knowledge of the password. | |||||
CVE-2015-3976 | 1 Ge | 14 Multilink Ml1200, Multilink Ml1200 Firmware, Multilink Ml1600 and 11 more | 2024-11-21 | 3.5 LOW | 5.4 MEDIUM |
Cross-site scripting (XSS) vulnerability in GE Multilink ML810/3000/3100 series switch 5.2.0 and earlier, and GE Multilink ML800/1200/1600/2400 4.2.1 and earlier. | |||||
CVE-2014-9203 | 2 Ge, Mactek | 4 12400 Level Transmitter Device Type Manager, Svi Ii Ap Positioner Device Type Manager, Vector Device Type Manager and 1 more | 2024-11-21 | 5.0 MEDIUM | N/A |
Buffer overflow in the Field Device Tool (FDT) Frame application in the HART Device Type Manager (DTM) library, as used in MACTek Bullet DTM 1.00.0, GE Vector DTM 1.00.0, GE SVi1000 Positioner DTM 1.00.0, GE SVI II AP Positioner DTM 2.00.1, and GE 12400 Level Transmitter DTM 1.00.0, allows remote attackers to cause a denial of service (DTM outage) via crafted packets. | |||||
CVE-2014-5419 | 1 Ge | 14 Multilink Ml1200, Multilink Ml1200 Firmware, Multilink Ml1600 and 11 more | 2024-11-21 | 5.0 MEDIUM | N/A |
GE Multilink ML800, ML1200, ML1600, and ML2400 switches with firmware 4.2.1 and earlier and Multilink ML810, ML3000, and ML3100 switches with firmware 5.2.0 and earlier use the same RSA private key across different customers' installations, which makes it easier for remote attackers to obtain the cleartext content of network traffic by reading this key from a firmware image and then sniffing the network. | |||||
CVE-2014-5418 | 1 Ge | 14 Multilink Ml1200, Multilink Ml1200 Firmware, Multilink Ml1600 and 11 more | 2024-11-21 | 7.8 HIGH | N/A |
GE Multilink ML800, ML1200, ML1600, and ML2400 switches with firmware 4.2.1 and earlier and Multilink ML810, ML3000, and ML3100 switches with firmware 5.2.0 and earlier allow remote attackers to cause a denial of service (resource consumption or reboot) via crafted packets. | |||||
CVE-2014-5409 | 1 Ge | 1 Hydran M2 | 2024-11-21 | 5.0 MEDIUM | N/A |
The 17046 Ethernet card before 94450214LFMT100SEM-L.R3-CL for the GE Digital Energy Hydran M2 does not properly generate random values for TCP Initial Sequence Numbers (ISNs), which makes it easier for remote attackers to spoof packets by predicting these values. | |||||
CVE-2014-2355 | 1 Ge | 1 Intelligent Platforms Proficy Hmi\/scada Cimplicity | 2024-11-21 | 6.9 MEDIUM | N/A |
The (1) CimView and (2) CimEdit components in GE Proficy HMI/SCADA-CIMPLICITY 8.2 and earlier allow remote attackers to gain privileges via a crafted CIMPLICITY screen (aka .CIM) file. | |||||
CVE-2014-0751 | 1 Ge | 3 Intelligent Platforms Proficy Hmi\%2fscada Cimplicity, Intelligent Platforms Proficy Hmi\/scada Cimplicity, Intelligent Platforms Proficy Process Systems With Cimplicity | 2024-11-21 | 7.5 HIGH | N/A |
Directory traversal vulnerability in CimWebServer.exe (aka the WebView component) in GE Intelligent Platforms Proficy HMI/SCADA - CIMPLICITY before 8.2 SIM 24, and Proficy Process Systems with CIMPLICITY, allows remote attackers to execute arbitrary code via a crafted message to TCP port 10212, aka ZDI-CAN-1623. | |||||
CVE-2014-0750 | 1 Ge | 3 Intelligent Platforms Proficy Hmi\%2fscada Cimplicity, Intelligent Platforms Proficy Hmi\/scada Cimplicity, Intelligent Platforms Proficy Process Systems With Cimplicity | 2024-11-21 | 7.5 HIGH | N/A |
Directory traversal vulnerability in gefebt.exe in the WebView CimWeb components in GE Intelligent Platforms Proficy HMI/SCADA - CIMPLICITY through 8.2 SIM 24, and Proficy Process Systems with CIMPLICITY, allows remote attackers to execute arbitrary code via a crafted HTTP request, aka ZDI-CAN-1622. | |||||
CVE-2013-2823 | 2 Catapultsoftware, Ge | 4 Catapult Dnp3 I\/o Driver, Intelligent Platforms Proficy Dnp3 I\/o Driver, Intelligent Platforms Proficy Hmi\/scada Cimplicity and 1 more | 2024-11-21 | 4.7 MEDIUM | N/A |
The (1) Catapult DNP3 I/O driver before 7.2.0.60 and the (2) GE Intelligent Platforms Proficy DNP3 I/O driver before 7.20k, as used in DNPDrv.exe (aka the DNP master station server) in GE Intelligent Platforms Proficy HMI/SCADA - CIMPLICITY and iFIX, allow physically proximate attackers to cause a denial of service (infinite loop) via crafted input over a serial line. | |||||
CVE-2013-2811 | 2 Catapultsoftware, Ge | 4 Catapult Dnp3 I\/o Driver, Intelligent Platforms Proficy Dnp3 I\/o Driver, Intelligent Platforms Proficy Hmi\/scada Cimplicity and 1 more | 2024-11-21 | 7.1 HIGH | N/A |
The (1) Catapult DNP3 I/O driver before 7.2.0.60 and the (2) GE Intelligent Platforms Proficy DNP3 I/O driver before 7.20k, as used in DNPDrv.exe (aka the DNP master station server) in GE Intelligent Platforms Proficy HMI/SCADA - CIMPLICITY and iFIX, allow remote attackers to cause a denial of service (infinite loop) via a crafted DNP3 TCP packet. |