CVE-2020-5806

An attacker-controlled memory allocation size can be passed to the C++ new operator in the CServerManager::HandleBrowseLoadIconStreamRequest in messaging.dll. This can be done by sending a specially crafted message to 127.0.0.1:7153. Observed in FactoryTalk Linx 6.11. All versions of FactoryTalk Linx are affected.
Configurations

Configuration 1 (hide)

cpe:2.3:a:rockwellautomation:factorytalk_linx:*:*:*:*:*:*:*:*

History

21 Nov 2024, 05:34

Type Values Removed Values Added
References () https://www.tenable.com/security/research/tra-2020-71 - Third Party Advisory () https://www.tenable.com/security/research/tra-2020-71 - Third Party Advisory

Information

Published : 2020-12-29 16:15

Updated : 2024-11-21 05:34


NVD link : CVE-2020-5806

Mitre link : CVE-2020-5806

CVE.ORG link : CVE-2020-5806


JSON object : View

Products Affected

rockwellautomation

  • factorytalk_linx
CWE
CWE-770

Allocation of Resources Without Limits or Throttling