An attacker-controlled memory allocation size can be passed to the C++ new operator in the CServerManager::HandleBrowseLoadIconStreamRequest in messaging.dll. This can be done by sending a specially crafted message to 127.0.0.1:7153. Observed in FactoryTalk Linx 6.11. All versions of FactoryTalk Linx are affected.
References
Link | Resource |
---|---|
https://www.tenable.com/security/research/tra-2020-71 | Third Party Advisory |
https://www.tenable.com/security/research/tra-2020-71 | Third Party Advisory |
Configurations
History
21 Nov 2024, 05:34
Type | Values Removed | Values Added |
---|---|---|
References | () https://www.tenable.com/security/research/tra-2020-71 - Third Party Advisory |
Information
Published : 2020-12-29 16:15
Updated : 2024-11-21 05:34
NVD link : CVE-2020-5806
Mitre link : CVE-2020-5806
CVE.ORG link : CVE-2020-5806
JSON object : View
Products Affected
rockwellautomation
- factorytalk_linx
CWE
CWE-770
Allocation of Resources Without Limits or Throttling