CVE-2022-34759 | 1 Schneider-electric | 4 Opc Ua Module For M580, Opc Ua Module For M580 Firmware, X80 Advanced Rtu Module and 1 more | 2024-11-21 | N/A | 7.5 HIGH |
A CWE-787: Out-of-bounds Write vulnerability exists that could cause a denial of service of the webserver due to improper parsing of the HTTP Headers. Affected Products: X80 advanced RTU Communication Module (BMENOR2200H) (V1.0), OPC UA Modicon Communication Module (BMENUA0100) (V1.10 and prior) | |||||
CVE-2022-34758 | 1 Schneider-electric | 2 Easergy P5, Easergy P5 Firmware | 2024-11-21 | N/A | 5.1 MEDIUM |
A CWE-20: Improper Input Validation vulnerability exists that could cause the device watchdog function to be disabled if the attacker had access to privileged user credentials. Affected Products: Easergy P5 (V01.401.102 and prior) | |||||
CVE-2022-34757 | 1 Schneider-electric | 2 Easergy P5, Easergy P5 Firmware | 2024-11-21 | N/A | 6.7 MEDIUM |
A CWE-327: Use of a Broken or Risky Cryptographic Algorithm vulnerability exists where weak cipher suites can be used for the SSH connection between Easergy Pro software and the device, which may allow an attacker to observe protected communication details. Affected Products: Easergy P5 (V01.401.102 and prior) | |||||
CVE-2022-34756 | 1 Schneider-electric | 2 Easergy P5, Easergy P5 Firmware | 2024-11-21 | N/A | 8.8 HIGH |
A CWE-120: Buffer Copy without Checking Size of Input vulnerability exists that could result in remote code execution or the crash of HTTPs stack which is used for the device Web HMI. Affected Products: Easergy P5 (V01.401.102 and prior) | |||||
CVE-2022-34755 | 1 Schneider-electric | 1 Easergy Builder Installer | 2024-11-21 | N/A | 6.3 MEDIUM |
A CWE-427 - Uncontrolled Search Path Element vulnerability exists that could allow an attacker with a local privileged account to place a specially crafted file on the target machine, which may give the attacker the ability to execute arbitrary code during the installation process initiated by a valid user. Affected Products: Easergy Builder Installer (1.7.23 and prior) | |||||
CVE-2022-34754 | 1 Schneider-electric | 4 Acti9 Powertag Link C \(a9xelc10-a\), Acti9 Powertag Link C \(a9xelc10-a\) Firmware, Acti9 Powertag Link C \(a9xelc10-b\) and 1 more | 2024-11-21 | N/A | 6.8 MEDIUM |
A CWE-269: Improper Privilege Management vulnerability exists that could allow elevated functionality when guessing credentials. Affected Products: Acti9 PowerTag Link C (A9XELC10-A) (V1.7.5 and prior), Acti9 PowerTag Link C (A9XELC10-B) (V2.12.0 and prior) | |||||
CVE-2022-34753 | 1 Schneider-electric | 2 Spacelogic C-bus Home Controller, Spacelogic C-bus Home Controller Firmware | 2024-11-21 | N/A | 8.8 HIGH |
A CWE-78: Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection') vulnerability exists that could cause remote root exploit when the command is compromised. Affected Products: SpaceLogic C-Bus Home Controller (5200WHC2), formerly known as C-Bus Wiser Homer Controller MK2 (V1.31.460 and prior) | |||||
CVE-2022-32748 | 1 Schneider-electric | 1 Ecostruxure Cybersecurity Admin Expert | 2024-11-21 | N/A | 7.9 HIGH |
A CWE-295: Improper Certificate Validation vulnerability exists that could cause the CAE software to give wrong data to end users when using CAE to configure devices. Additionally, credentials could leak which would enable an attacker the ability to log into the configuration tool and compromise other devices in the network. Affected Products: EcoStruxure™ Cybersecurity Admin Expert (CAE) (Versions prior to 2.2) | |||||
CVE-2022-32747 | 1 Schneider-electric | 1 Ecostruxure Cybersecurity Admin Expert | 2024-11-21 | N/A | 8.0 HIGH |
A CWE-290: Authentication Bypass by Spoofing vulnerability exists that could cause legitimate users to be locked out of devices or facilitate backdoor account creation by spoofing a device on the local network. Affected Products: EcoStruxure™ Cybersecurity Admin Expert (CAE) (Versions prior to 2.2) | |||||
CVE-2022-32530 | 1 Schneider-electric | 1 Geo Scada Mobile | 2024-11-21 | 6.8 MEDIUM | 4.8 MEDIUM |
A CWE-668 Exposure of Resource to Wrong Sphere vulnerability exists that could cause users to be misled, hiding alarms, showing the wrong server connection option or the wrong control request when a mobile device has been compromised by a malicious application. Affected Product: Geo SCADA Mobile (Build 222 and prior) | |||||
CVE-2022-32529 | 1 Schneider-electric | 1 Interactive Graphical Scada System | 2024-11-21 | N/A | 9.8 CRITICAL |
A CWE-120: Buffer Copy without Checking Size of Input vulnerability exists that could cause a stack-based buffer overflow, potentially leading to remote code execution when an attacker sends specially crafted log data request messages. Affected Products: IGSS Data Server - IGSSdataServer.exe (Versions prior to V15.0.0.22170) | |||||
CVE-2022-32528 | 1 Schneider-electric | 1 Interactive Graphical Scada System | 2024-11-21 | N/A | 8.6 HIGH |
A CWE-306: Missing Authentication for Critical Function vulnerability exists that could cause access to manipulate and read specific files in the IGSS project report directory, potentially leading to a denial-of-service condition when an attacker sends specific messages. Affected Products: IGSS Data Server - IGSSdataServer.exe (Versions prior to V15.0.0.22170) | |||||
CVE-2022-32527 | 1 Schneider-electric | 1 Interactive Graphical Scada System | 2024-11-21 | N/A | 9.8 CRITICAL |
A CWE-120: Buffer Copy without Checking Size of Input vulnerability exists that could cause a stack-based buffer overflow, potentially leading to remote code execution when an attacker sends specially crafted alarm cache data messages. Affected Products: IGSS Data Server - IGSSdataServer.exe (Versions prior to V15.0.0.22170) | |||||
CVE-2022-32526 | 1 Schneider-electric | 1 Interactive Graphical Scada System | 2024-11-21 | N/A | 9.8 CRITICAL |
A CWE-120: Buffer Copy without Checking Size of Input vulnerability exists that could cause a stack-based buffer overflow, potentially leading to remote code execution when an attacker sends specially crafted setting value messages. Affected Products: IGSS Data Server - IGSSdataServer.exe (Versions prior to V15.0.0.22170) | |||||
CVE-2022-32525 | 1 Schneider-electric | 1 Interactive Graphical Scada System | 2024-11-21 | N/A | 9.8 CRITICAL |
A CWE-120: Buffer Copy without Checking Size of Input vulnerability exists that could cause a stack-based buffer overflow, potentially leading to remote code execution when an attacker sends specially crafted alarm data messages. Affected Products: IGSS Data Server - IGSSdataServer.exe (Versions prior to V15.0.0.22170) | |||||
CVE-2022-32524 | 1 Schneider-electric | 1 Interactive Graphical Scada System | 2024-11-21 | N/A | 9.8 CRITICAL |
A CWE-120: Buffer Copy without Checking Size of Input vulnerability exists that could cause a stack-based buffer overflow, potentially leading to remote code execution when an attacker sends specially crafted time reduced data messages. Affected Products: IGSS Data Server - IGSSdataServer.exe (Versions prior to V15.0.0.22170) | |||||
CVE-2022-32523 | 1 Schneider-electric | 1 Interactive Graphical Scada System | 2024-11-21 | N/A | 9.8 CRITICAL |
A CWE-120: Buffer Copy without Checking Size of Input vulnerability exists that could cause a stack-based buffer overflow, potentially leading to remote code execution when an attacker sends specially crafted online data request messages. Affected Products: IGSS Data Server - IGSSdataServer.exe (Versions prior to V15.0.0.22170) | |||||
CVE-2022-32522 | 1 Schneider-electric | 1 Interactive Graphical Scada System | 2024-11-21 | N/A | 9.8 CRITICAL |
A CWE-120: Buffer Copy without Checking Size of Input vulnerability exists that could cause a stack-based buffer overflow, potentially leading to remote code execution when an attacker sends specially crafted mathematically reduced data request messages. Affected Products: IGSS Data Server - IGSSdataServer.exe (Versions prior to V15.0.0.22170) | |||||
CVE-2022-32521 | 1 Schneider-electric | 1 Data Center Expert | 2024-11-21 | N/A | 7.1 HIGH |
A CWE 502: Deserialization of Untrusted Data vulnerability exists that could allow code to be remotely executed on the server when unsafely deserialized data is posted to the web server. Affected Products: Data Center Expert (Versions prior to V7.9.0) | |||||
CVE-2022-32520 | 1 Schneider-electric | 1 Data Center Expert | 2024-11-21 | N/A | 8.0 HIGH |
A CWE-522: Insufficiently Protected Credentials vulnerability exists that could result in unwanted access to a DCE instance when performed over a network by a malicious third-party. This CVE is unique from CVE-2022-32518. Affected Products: Data Center Expert (Versions prior to V7.9.0) |