Vulnerabilities (CVE)

Filtered by vendor Schneider-electric Subscribe
Total 752 CVE
CVE Vendors Products Updated CVSS v2 CVSS v3
CVE-2023-29413 2 Microsoft, Schneider-electric 7 Windows 10, Windows 11, Windows Server 2016 and 4 more 2024-02-28 N/A 7.5 HIGH
A CWE-306: Missing Authentication for Critical Function vulnerability exists that could cause Denial-of-Service when accessed by an unauthenticated user on the Schneider UPS Monitor service.
CVE-2023-2570 1 Schneider-electric 1 Ecostruxure Foxboro Dcs Control Core Services 2024-02-28 N/A 7.8 HIGH
A CWE-129: Improper Validation of Array Index vulnerability exists that could cause local denial-of-service, and potentially kernel execution when a malicious actor with local user access crafts a script/program using an unpredictable index to an IOCTL call in the Foxboro.sys driver.
CVE-2023-27980 1 Schneider-electric 3 Custom Reports, Igss Dashboard, Igss Data Server 2024-02-28 N/A 8.8 HIGH
A CWE-306: Missing Authentication for Critical Function vulnerability exists in the Data Server TCP interface that could allow the creation of a malicious report file in the IGSS project report directory, this could lead to remote code execution when a victim eventually opens the report. Affected Products: IGSS Data Server(IGSSdataServer.exe)(V16.0.0.23040 and prior), IGSS Dashboard(DashBoard.exe)(V16.0.0.23040 and prior), Custom Reports(RMS16.dll)(V16.0.0.23040 and prior)
CVE-2023-25552 1 Schneider-electric 1 Struxureware Data Center Expert 2024-02-28 N/A 8.1 HIGH
A CWE-862: Missing Authorization vulnerability exists that could allow viewing of unauthorized content, changes or deleting of content, or performing unauthorized functions when tampering the Device File Transfer settings on DCE endpoints. Affected products: StruxureWare Data Center Expert (V7.9.2 and prior)
CVE-2023-37198 1 Schneider-electric 1 Struxureware Data Center Expert 2024-02-28 N/A 7.2 HIGH
A CWE-94: Improper Control of Generation of Code ('Code Injection') vulnerability exists that could cause remote code execution when an admin user on DCE uploads or tampers with install packages.
CVE-2023-25549 1 Schneider-electric 1 Struxureware Data Center Expert 2024-02-28 N/A 9.8 CRITICAL
A CWE-94: Improper Control of Generation of Code ('Code Injection') vulnerability exists that allows for remote code execution when using a parameter of the DCE network settings endpoint. Affected products: StruxureWare Data Center Expert (V7.9.2 and prior)
CVE-2023-25553 1 Schneider-electric 1 Struxureware Data Center Expert 2024-02-28 N/A 6.1 MEDIUM
A CWE-79: Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting') vulnerability exists on a DCE endpoint through the logging capabilities of the webserver. Affected products: StruxureWare Data Center Expert (V7.9.2 and prior)
CVE-2022-34755 1 Schneider-electric 1 Easergy Builder Installer 2024-02-28 N/A 6.7 MEDIUM
A CWE-427 - Uncontrolled Search Path Element vulnerability exists that could allow an attacker with a local privileged account to place a specially crafted file on the target machine, which may give the attacker the ability to execute arbitrary code during the installation process initiated by a valid user. Affected Products: Easergy Builder Installer (1.7.23 and prior)
CVE-2023-25554 1 Schneider-electric 1 Struxureware Data Center Expert 2024-02-28 N/A 7.8 HIGH
A CWE-78: Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection') vulnerability exists that allows a local privilege escalation on the appliance when a maliciously crafted Operating System command is entered on the device. Affected products: StruxureWare Data Center Expert (V7.9.2 and prior)
CVE-2022-22732 1 Schneider-electric 1 Ecostruxure Power Commission 2024-02-28 N/A 7.5 HIGH
A CWE-668: Exposure of Resource to Wrong Sphere vulnerability exists that could cause all remote domains to access the resources (data) supplied by the server when an attacker sends a fetch request from third-party site or malicious site. Affected Products: EcoStruxure Power Commission (Versions prior to V2.22)
CVE-2022-32513 1 Schneider-electric 12 5500ac2, 5500ac2 Firmware, 5500nac and 9 more 2024-02-28 N/A 9.8 CRITICAL
A CWE-521: Weak Password Requirements vulnerability exists that could allow an attacker to gain control of the device when the attacker brute forces the password. Affected Products: C-Bus Network Automation Controller - LSS5500NAC (Versions prior to V1.10.0), Wiser for C-Bus Automation Controller - LSS5500SHAC (Versions prior to V1.10.0), Clipsal C-Bus Network Automation Controller - 5500NAC (Versions prior to V1.10.0), Clipsal Wiser for C-Bus Automation Controller - 5500SHAC (Versions prior to V1.10.0), SpaceLogic C-Bus Network Automation Controller - 5500NAC2 (Versions prior to V1.10.0), SpaceLogic C-Bus Application Controller - 5500AC2 (Versions prior to V1.10.0)
CVE-2022-2329 1 Schneider-electric 1 Interactive Graphical Scada System 2024-02-28 N/A 9.8 CRITICAL
A CWE-190: Integer Overflow or Wraparound vulnerability exists that could cause heap-based buffer overflow, leading to denial of service and potentially remote code execution when an attacker sends multiple specially crafted messages. Affected Products: IGSS Data Server - IGSSdataServer.exe (Versions prior to V15.0.0.22073)
CVE-2022-32516 1 Schneider-electric 2 Conext Combox, Conext Combox Firmware 2024-02-28 N/A 6.5 MEDIUM
A CWE-352: Cross-Site Request Forgery (CSRF) vulnerability exists that could cause system’s configurations override and cause a reboot loop when the product suffers from POST-Based Cross-Site Request Forgery (CSRF). Affected Products: Conext™ ComBox (All Versions)
CVE-2022-42972 2 Microsoft, Schneider-electric 8 Windows 10, Windows 11, Windows 7 and 5 more 2024-02-28 N/A 7.8 HIGH
A CWE-732: Incorrect Permission Assignment for Critical Resource vulnerability exists that could cause local privilege escalation when a local attacker modifies the webroot directory. Affected Products: APC Easy UPS Online Monitoring Software (Windows 7, 10, 11 & Windows Server 2016, 2019, 2022 - Versions prior to V2.5-GA), APC Easy UPS Online Monitoring Software (Windows 11, Windows Server 2019, 2022 - Versions prior to V2.5-GA-01-22261), Schneider Electric Easy UPS Online Monitoring Software (Windows 7, 10, 11 & Windows Server 2016, 2019, 2022 - Versions prior to V2.5-GS), Schneider Electric Easy UPS Online Monitoring Software (Windows 11, Windows Server 2019, 2022 - Versions prior to V2.5-GS-01-22261)
CVE-2022-32518 1 Schneider-electric 1 Data Center Expert 2024-02-28 N/A 9.8 CRITICAL
A CWE-522: Insufficiently Protected Credentials vulnerability exists that could result in unwanted access to a DCE instance when performed over a network by a malicious third-party. This CVE is unique from CVE-2022-32520. Affected Products: Data Center Expert (Versions prior to V7.9.0)
CVE-2022-24324 1 Schneider-electric 1 Interactive Graphical Scada System 2024-02-28 N/A 9.8 CRITICAL
A CWE-120: Buffer Copy without Checking Size of Input vulnerability exists that could cause a stack-based buffer overflow potentially leading to remote code execution when an attacker sends a specially crafted message. Affected Products: IGSS Data Server - IGSSdataServer.exe (Versions prior to V15.0.0.22073)
CVE-2022-32522 1 Schneider-electric 1 Interactive Graphical Scada System 2024-02-28 N/A 9.8 CRITICAL
A CWE-120: Buffer Copy without Checking Size of Input vulnerability exists that could cause a stack-based buffer overflow, potentially leading to remote code execution when an attacker sends specially crafted mathematically reduced data request messages. Affected Products: IGSS Data Server - IGSSdataServer.exe (Versions prior to V15.0.0.22170)
CVE-2022-32514 1 Schneider-electric 12 5500ac2, 5500ac2 Firmware, 5500nac and 9 more 2024-02-28 N/A 9.8 CRITICAL
A CWE-287: Improper Authentication vulnerability exists that could allow an attacker to gain control of the device when logging into a web page. Affected Products: C-Bus Network Automation Controller - LSS5500NAC (Versions prior to V1.10.0), Wiser for C-Bus Automation Controller - LSS5500SHAC (Versions prior to V1.10.0), Clipsal C-Bus Network Automation Controller - 5500NAC (Versions prior to V1.10.0), Clipsal Wiser for C-Bus Automation Controller - 5500SHAC (Versions prior to V1.10.0), SpaceLogic C-Bus Network Automation Controller - 5500NAC2 (Versions prior to V1.10.0), SpaceLogic C-Bus Application Controller - 5500AC2 (Versions prior to V1.10.0)
CVE-2022-32747 1 Schneider-electric 1 Ecostruxure Cybersecurity Admin Expert 2024-02-28 N/A 8.1 HIGH
A CWE-290: Authentication Bypass by Spoofing vulnerability exists that could cause legitimate users to be locked out of devices or facilitate backdoor account creation by spoofing a device on the local network. Affected Products: EcoStruxure™ Cybersecurity Admin Expert (CAE) (Versions prior to 2.2)
CVE-2022-32523 1 Schneider-electric 1 Interactive Graphical Scada System 2024-02-28 N/A 9.8 CRITICAL
A CWE-120: Buffer Copy without Checking Size of Input vulnerability exists that could cause a stack-based buffer overflow, potentially leading to remote code execution when an attacker sends specially crafted online data request messages. Affected Products: IGSS Data Server - IGSSdataServer.exe (Versions prior to V15.0.0.22170)