CVE-2022-41671 | 1 Schneider-electric | 2 Ecostruxure Operator Terminal Expert, Pro-face Blue | 2024-02-28 | N/A | 7.8 HIGH |
A CWE-89: Improper Neutralization of Special Elements used in SQL Command (‘SQL Injection’) vulnerability exists that allows adversaries with local user privileges to craft a malicious SQL query and execute as part of project migration which could result in execution of malicious code. Affected Products: EcoStruxure Operator Terminal Expert(V3.3 Hotfix 1 or prior), Pro-face BLUE(V3.3 Hotfix1 or prior). | |||||
CVE-2022-34765 | 1 Schneider-electric | 4 Opc Ua Module For M580, Opc Ua Module For M580 Firmware, X80 Advanced Rtu Module and 1 more | 2024-02-28 | N/A | 5.3 MEDIUM |
A CWE-73: External Control of File Name or Path vulnerability exists that could cause loading of unauthorized firmware images when user-controlled data is written to the file path. Affected Products: X80 advanced RTU Communication Module (BMENOR2200H) (V2.01 and later), OPC UA Modicon Communication Module (BMENUA0100) (V1.10 and prior) | |||||
CVE-2022-34756 | 1 Schneider-electric | 2 Easergy P5, Easergy P5 Firmware | 2024-02-28 | N/A | 9.8 CRITICAL |
A CWE-120: Buffer Copy without Checking Size of Input vulnerability exists that could result in remote code execution or the crash of HTTPs stack which is used for the device Web HMI. Affected Products: Easergy P5 (V01.401.102 and prior) | |||||
CVE-2022-41668 | 1 Schneider-electric | 2 Ecostruxure Operator Terminal Expert, Pro-face Blue | 2024-02-28 | N/A | 7.8 HIGH |
A CWE-704: Incorrect Project Conversion vulnerability exists that allows adversaries with local user privileges to load a project file from an adversary-controlled network share which could result in execution of malicious code. Affected Products: EcoStruxure Operator Terminal Expert(V3.3 Hotfix 1 or prior), Pro-face BLUE(V3.3 Hotfix1 or prior). | |||||
CVE-2022-34760 | 1 Schneider-electric | 4 Opc Ua Module For M580, Opc Ua Module For M580 Firmware, X80 Advanced Rtu Module and 1 more | 2024-02-28 | N/A | 7.5 HIGH |
A CWE-835: Loop with Unreachable Exit Condition ('Infinite Loop') vulnerability exists that could cause a denial of service of the webserver due to improper handling of the cookies. Affected Products: X80 advanced RTU Communication Module (BMENOR2200H) (V1.0), OPC UA Modicon Communication Module (BMENUA0100) (V1.10 and prior) | |||||
CVE-2022-34762 | 1 Schneider-electric | 4 Opc Ua Module For M580, Opc Ua Module For M580 Firmware, X80 Advanced Rtu Module and 1 more | 2024-02-28 | N/A | 7.5 HIGH |
A CWE-22: Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal') vulnerability exists that could cause unauthorized firmware image loading when unsigned images are added to the firmware image path. Affected Products: X80 advanced RTU Communication Module (BMENOR2200H) (V2.01 and later), OPC UA Modicon Communication Module (BMENUA0100) (V1.10 and prior) | |||||
CVE-2022-34759 | 1 Schneider-electric | 4 Opc Ua Module For M580, Opc Ua Module For M580 Firmware, X80 Advanced Rtu Module and 1 more | 2024-02-28 | N/A | 7.5 HIGH |
A CWE-787: Out-of-bounds Write vulnerability exists that could cause a denial of service of the webserver due to improper parsing of the HTTP Headers. Affected Products: X80 advanced RTU Communication Module (BMENOR2200H) (V1.0), OPC UA Modicon Communication Module (BMENUA0100) (V1.10 and prior) | |||||
CVE-2022-30236 | 1 Schneider-electric | 4 Wiser Smart Eer21000, Wiser Smart Eer21000 Firmware, Wiser Smart Eer21001 and 1 more | 2024-02-28 | 6.4 MEDIUM | 8.2 HIGH |
A CWE-669: Incorrect Resource Transfer Between Spheres vulnerability exists that could allow unauthorized access when an attacker uses cross-domain attacks. Affected Products: Wiser Smart, EER21000 & EER21001 (V4.5 and prior) | |||||
CVE-2022-30237 | 1 Schneider-electric | 4 Wiser Smart Eer21000, Wiser Smart Eer21000 Firmware, Wiser Smart Eer21001 and 1 more | 2024-02-28 | 5.0 MEDIUM | 7.5 HIGH |
A CWE-311: Missing Encryption of Sensitive Data vulnerability exists that could allow authentication credentials to be recovered when an attacker breaks the encoding. Affected Products: Wiser Smart, EER21000 & EER21001 (V4.5 and prior) | |||||
CVE-2022-30235 | 1 Schneider-electric | 4 Wiser Smart Eer21000, Wiser Smart Eer21000 Firmware, Wiser Smart Eer21001 and 1 more | 2024-02-28 | 5.0 MEDIUM | 9.8 CRITICAL |
A CWE-307: Improper Restriction of Excessive Authentication Attempts vulnerability exists that could allow unauthorized access when an attacker uses brute force. Affected Products: Wiser Smart, EER21000 & EER21001 (V4.5 and prior) | |||||
CVE-2022-32530 | 1 Schneider-electric | 1 Geo Scada Mobile | 2024-02-28 | 6.8 MEDIUM | 7.8 HIGH |
A CWE-668 Exposure of Resource to Wrong Sphere vulnerability exists that could cause users to be misled, hiding alarms, showing the wrong server connection option or the wrong control request when a mobile device has been compromised by a malicious application. Affected Product: Geo SCADA Mobile (Build 222 and prior) | |||||
CVE-2022-30238 | 1 Schneider-electric | 4 Wiser Smart Eer21000, Wiser Smart Eer21000 Firmware, Wiser Smart Eer21001 and 1 more | 2024-02-28 | 7.5 HIGH | 8.8 HIGH |
A CWE-287: Improper Authentication vulnerability exists that could allow an attacker to take over the admin account when an attacker hijacks a session. Affected Products: Wiser Smart, EER21000 & EER21001 (V4.5 and prior) | |||||
CVE-2022-30234 | 1 Schneider-electric | 4 Wiser Smart Eer21000, Wiser Smart Eer21000 Firmware, Wiser Smart Eer21001 and 1 more | 2024-02-28 | 10.0 HIGH | 9.8 CRITICAL |
A CWE-798: Use of Hard-coded Credentials vulnerability exists that could allow arbitrary code to be executed when root level access is obtained. Affected Products: Wiser Smart, EER21000 & EER21001 (V4.5 and prior) | |||||
CVE-2022-30232 | 1 Schneider-electric | 2 Powerlogic Ion Setup, Powerlogic Ion Setup Firmware | 2024-02-28 | 6.5 MEDIUM | 8.8 HIGH |
A CWE-20: Improper Input Validation vulnerability exists that could cause potential remote code execution when an attacker is able to intercept and modify a request on the same network or has configuration access to an ION device on the network. Affected Products: Wiser Smart, EER21000 & EER21001 (V4.5 and prior) | |||||
CVE-2022-30233 | 1 Schneider-electric | 4 Wiser Smart Eer21000, Wiser Smart Eer21000 Firmware, Wiser Smart Eer21001 and 1 more | 2024-02-28 | 4.3 MEDIUM | 6.5 MEDIUM |
A CWE-20: Improper Input Validation vulnerability exists that could allow the product to be maliciously manipulated when the user is tricked into performing certain actions on a webpage. Affected Products: Wiser Smart, EER21000 & EER21001 (V4.5 and prior) |