Vulnerabilities (CVE)

Filtered by vendor Schneider-electric Subscribe
Total 751 CVE
CVE Vendors Products Updated CVSS v2 CVSS v3
CVE-2024-5559 1 Schneider-electric 2 Powerlogic P5, Powerlogic P5 Firmware 2024-08-23 N/A 6.8 MEDIUM
CWE-327: Use of a Broken or Risky Cryptographic Algorithm vulnerability exists that could cause denial of service, device reboot, or an attacker gaining full control of the relay when a specially crafted reset token is entered into the front panel of the device.
CVE-2024-2747 1 Schneider-electric 1 Easergy Studio 2024-08-23 N/A 7.8 HIGH
CWE-428: Unquoted search path or element vulnerability exists in Easergy Studio, which could cause privilege escalation when a valid user replaces a trusted file name on the system and reboots the machine.
CVE-2024-5056 1 Schneider-electric 6 Bmxnoe0100, Bmxnoe0100 Firmware, Bmxnoe0110 and 3 more 2024-08-23 N/A 6.5 MEDIUM
CWE-552: Files or Directories Accessible to External Parties vulnerability exists which may prevent user to update the device firmware and prevent proper behavior of the webserver when specific files or directories are removed from the filesystem.
CVE-2024-37036 1 Schneider-electric 7 Sage 1410, Sage 1430, Sage 1450 and 4 more 2024-08-14 N/A 9.8 CRITICAL
CWE-787: Out-of-bounds Write vulnerability exists that could result in an authentication bypass when sending a malformed POST request and particular configuration parameters are set.
CVE-2024-5313 1 Schneider-electric 2 Evlink Home, Evlink Home Firmware 2024-08-14 N/A 6.5 MEDIUM
CWE-668: Exposure of the Resource Wrong Sphere vulnerability exists that exposes a SSH interface over the product network interface. This does not allow to directly exploit the product or make any unintended operation as the SSH interface access is protected by an authentication mechanism. Impacts are limited to port scanning and fingerprinting activities as well as attempts to perform a potential denial of service attack on the exposed SSH interface.
CVE-2013-2763 1 Schneider-electric 24 Modicon M340 Bmx Noc 0401, Modicon M340 Bmx Noc 0401 Firmware, Modicon M340 Bmx Noe 0100 and 21 more 2024-08-06 5.0 MEDIUM N/A
The Schneider Electric M340 PLC modules allow remote attackers to cause a denial of service (resource consumption) via unspecified vectors. NOTE: the vendor reportedly disputes this issue because it "could not be duplicated" and "an attacker could not remotely exploit this observed behavior to deny PLC control functions.
CVE-2021-22768 1 Schneider-electric 4 Powerlogic Egx100, Powerlogic Egx100 Firmware, Powerlogic Egx300 and 1 more 2024-08-03 7.5 HIGH 9.8 CRITICAL
A CWE-20: Improper Input Validation vulnerability exists in PowerLogic EGX100 (Versions 3.0.0 and newer) and PowerLogic EGX300 (All Versions) that could cause denial of service or remote code execution via a specially crafted HTTP packet.This CVE ID is unique from CVE-2021-22767
CVE-2021-22767 1 Schneider-electric 4 Powerlogic Egx100, Powerlogic Egx100 Firmware, Powerlogic Egx300 and 1 more 2024-08-03 7.5 HIGH 9.8 CRITICAL
A CWE-20: Improper Input Validation vulnerability exists in PowerLogic EGX100 (Versions 3.0.0 and newer) and PowerLogic EGX300 (All Versions) that could cause denial of service or remote code execution via a specially crafted HTTP packet.This CVE ID is unique from CVE-2021-2276
CVE-2021-22766 1 Schneider-electric 4 Powerlogic Egx100, Powerlogic Egx100 Firmware, Powerlogic Egx300 and 1 more 2024-08-03 5.0 MEDIUM 7.5 HIGH
A CWE-20: Improper Input Validation vulnerability exists in PowerLogic EGX100 (Versions 3.0.0 and newer) and PowerLogic EGX300 (All Versions) that could cause denial of service via a specially crafted HTTP packet
CVE-2021-22765 1 Schneider-electric 4 Powerlogic Egx100, Powerlogic Egx100 Firmware, Powerlogic Egx300 and 1 more 2024-08-03 7.5 HIGH 9.8 CRITICAL
A CWE-20: Improper Input Validation vulnerability exists in PowerLogic EGX100 (Versions 3.0.0 and newer) and PowerLogic EGX300 (All Versions) that could cause denial of service or remote code execution via a specially crafted HTTP packet
CVE-2022-26507 2 Att, Schneider-electric 9 Xmill, Ecostruxure Control Expert, Ecostruxure Process Expert and 6 more 2024-08-03 7.5 HIGH 9.8 CRITICAL
A heap-based buffer overflow exists in XML Decompression DecodeTreeBlock in AT&T Labs Xmill 0.7. A crafted input file can lead to remote code execution. This is not the same as any of: CVE-2021-21810, CVE-2021-21811, CVE-2021-21812, CVE-2021-21815, CVE-2021-21825, CVE-2021-21826, CVE-2021-21828, CVE-2021-21829, or CVE-2021-21830. NOTE: This vulnerability only affects products that are no longer supported by the maintainer
CVE-2024-37037 1 Schneider-electric 7 Sage 1410, Sage 1430, Sage 1450 and 4 more 2024-07-25 N/A 8.1 HIGH
CWE-22: Improper Limitation of a Pathname to a Restricted Directory (‘Path Traversal’) vulnerability exists that could allow an authenticated user with access to the device’s web interface to corrupt files and impact device functionality when sending a crafted HTTP request.
CVE-2024-37038 1 Schneider-electric 7 Sage 1410, Sage 1430, Sage 1450 and 4 more 2024-07-25 N/A 8.8 HIGH
CWE-276: Incorrect Default Permissions vulnerability exists that could allow an authenticated user with access to the device’s web interface to perform unauthorized file and firmware uploads when crafting custom web requests.
CVE-2024-37039 1 Schneider-electric 7 Sage 1410, Sage 1430, Sage 1450 and 4 more 2024-07-25 N/A 7.5 HIGH
CWE-252: Unchecked Return Value vulnerability exists that could cause denial of service of the device when an attacker sends a specially crafted HTTP request.
CVE-2024-37040 1 Schneider-electric 7 Sage 1410, Sage 1430, Sage 1450 and 4 more 2024-07-25 N/A 8.1 HIGH
CWE-120: Buffer Copy without Checking Size of Input (‘Classic Buffer Overflow’) vulnerability exists that could allow a user with access to the device’s web interface to cause a fault on the device when sending a malformed HTTP request.
CVE-2024-5557 1 Schneider-electric 4 Spacelogic As-b, Spacelogic As-b Firmware, Spacelogic As-p and 1 more 2024-07-25 N/A 4.5 MEDIUM
CWE-532: Insertion of Sensitive Information into Log File vulnerability exists that could cause exposure of SNMP credentials when an attacker has access to the controller logs.
CVE-2024-5558 1 Schneider-electric 4 Spacelogic As-b, Spacelogic As-b Firmware, Spacelogic As-p and 1 more 2024-07-25 N/A 6.4 MEDIUM
CWE-367: Time-of-check Time-of-use (TOCTOU) Race Condition vulnerability exists that could cause escalation of privileges when an attacker abuses a limited admin account.
CVE-2024-5560 1 Schneider-electric 7 Sage 1410, Sage 1430, Sage 1450 and 4 more 2024-07-25 N/A 7.5 HIGH
CWE-125: Out-of-bounds Read vulnerability exists that could cause denial of service of the device’s web interface when an attacker sends a specially crafted HTTP request.
CVE-2024-0865 1 Schneider-electric 1 Ecostruxure It Gateway 2024-07-19 N/A 7.8 HIGH
CWE-798: Use of hard-coded credentials vulnerability exists that could cause local privilege escalation when logged in as a non-administrative user.
CVE-2024-2602 1 Schneider-electric 1 Foxrtu Station 2024-07-12 N/A 7.8 HIGH
CWE-22: Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal') vulnerability exists that could result in remote code execution when an authenticated user executes a saved project file that has been tampered by a malicious actor.