Filtered by vendor Schneider-electric
Subscribe
Total
755 CVE
CVE | Vendors | Products | Updated | CVSS v2 | CVSS v3 |
---|---|---|---|---|---|
CVE-2013-3075 | 2 Mitsubishi-automation, Schneider-electric | 3 Mitsubishi Mx Component, Citectfacilities, Citectscada | 2024-11-21 | 10.0 HIGH | N/A |
Multiple buffer overflows in ActUWzd.dll 1.0.0.1 in Mitsubishi MX Component 3, as distributed in Citect CitectFacilities 7.10 and CitectScada 7.10r1, allow remote attackers to execute arbitrary code via a long string, as demonstrated by a long WzTitle property value to a certain ActiveX control. | |||||
CVE-2013-2796 | 1 Schneider-electric | 3 Citectscada, Powerlogic Scada, Vijeo Citect | 2024-11-21 | 6.9 MEDIUM | N/A |
Schneider Electric Vijeo Citect 7.20 and earlier, CitectSCADA 7.20 and earlier, and PowerLogic SCADA 7.20 and earlier allow remote attackers to read arbitrary files, send HTTP requests to intranet servers, or cause a denial of service (CPU and memory consumption) via an XML document containing an external entity declaration in conjunction with an entity reference, related to an XML External Entity (XXE) issue. | |||||
CVE-2013-2782 | 1 Schneider-electric | 2 Tburjr900, Tburjr900 Firmware | 2024-11-21 | 9.3 HIGH | N/A |
Schneider Electric Trio J-Series License Free Ethernet Radio with firmware 3.6.0 through 3.6.3 uses the same AES encryption key across different customers' installations, which makes it easier for remote attackers to defeat cryptographic protection mechanisms by leveraging knowledge of this key from another installation. | |||||
CVE-2013-2763 | 1 Schneider-electric | 24 Modicon M340 Bmx Noc 0401, Modicon M340 Bmx Noc 0401 Firmware, Modicon M340 Bmx Noe 0100 and 21 more | 2024-11-21 | 5.0 MEDIUM | N/A |
The Schneider Electric M340 PLC modules allow remote attackers to cause a denial of service (resource consumption) via unspecified vectors. NOTE: the vendor reportedly disputes this issue because it "could not be duplicated" and "an attacker could not remotely exploit this observed behavior to deny PLC control functions. | |||||
CVE-2013-2762 | 1 Schneider-electric | 1 Magelis Xbt Hmi | 2024-11-21 | 10.0 HIGH | N/A |
The Schneider Electric Magelis XBT HMI controller has a default password for authentication of configuration uploads, which makes it easier for remote attackers to bypass intended access restrictions via crafted configuration data. | |||||
CVE-2013-2761 | 1 Schneider-electric | 1 Modicon M340 | 2024-11-21 | 4.0 MEDIUM | N/A |
The Schneider Electric M340 BMXNOE01xx and BMXP3420xx PLC modules allow remote authenticated users to cause a denial of service (module crash) via crafted FTP traffic, as demonstrated by the FileZilla FTP client. | |||||
CVE-2013-0687 | 1 Schneider-electric | 1 Micom S1 Studio | 2024-11-21 | 6.6 MEDIUM | N/A |
The installer routine in Schneider Electric MiCOM S1 Studio uses world-writable permissions for executable files, which allows local users to modify the service or the configuration files, and consequently gain privileges or trigger incorrect protective-relay operation, via a Trojan horse executable file. | |||||
CVE-2013-0664 | 1 Schneider-electric | 3 Modicon M340, Modicon Premium, Modicon Quantum Plc | 2024-11-21 | 8.5 HIGH | N/A |
The FactoryCast service on the Schneider Electric Quantum 140NOE77111 and 140NWM10000, M340 BMXNOE0110x, and Premium TSXETY5103 PLC modules allows remote authenticated users to send Modbus messages, and consequently execute arbitrary code, by embedding these messages in SOAP HTTP POST requests. | |||||
CVE-2013-0663 | 1 Schneider-electric | 3 Modicon M340, Modicon Premium, Modicon Quantum Plc | 2024-11-21 | 6.8 MEDIUM | N/A |
Cross-site request forgery (CSRF) vulnerability on the Schneider Electric Quantum 140NOE77111, 140NOE77101, and 140NWM10000; M340 BMXNOC0401, BMXNOE0100x, and BMXNOE011xx; and Premium TSXETY4103, TSXETY5103, and TSXWMY100 PLC modules allows remote attackers to hijack the authentication of arbitrary users for requests that execute commands, as demonstrated by modifying HTTP credentials. | |||||
CVE-2013-0658 | 1 Schneider-electric | 1 Accutech Manager | 2024-11-21 | 10.0 HIGH | N/A |
Heap-based buffer overflow in RFManagerService.exe in Schneider Electric Accutech Manager 2.00.1 and earlier allows remote attackers to execute arbitrary code via a crafted HTTP request. | |||||
CVE-2013-0657 | 1 Schneider-electric | 1 Interactive Graphical Scada System | 2024-11-21 | 10.0 HIGH | N/A |
Stack-based buffer overflow in Schneider Electric Interactive Graphical SCADA System (IGSS) 10 and earlier allows remote attackers to execute arbitrary code by sending TCP port-12397 data that does not comply with a protocol. | |||||
CVE-2013-0655 | 1 Schneider-electric | 1 Software Update Utility | 2024-11-21 | 9.3 HIGH | N/A |
The client in Schneider Electric Software Update (SESU) Utility 1.0.x and 1.1.x does not ensure that updates have a valid origin, which allows man-in-the-middle attackers to spoof updates, and consequently execute arbitrary code, by modifying the data stream on TCP port 80. | |||||
CVE-2012-1990 | 1 Schneider-electric | 2 Kerweb, Kerwin | 2024-11-21 | 4.3 MEDIUM | N/A |
Multiple cross-site scripting (XSS) vulnerabilities in Schneider Electric Kerweb before 3.0.1 and Kerwin before 6.0.1 allow remote attackers to inject arbitrary web script or HTML via (1) the evtvariablename parameter in an evts.xml action to kw.dll, (2) unspecified search fields, or (3) unspecified content-display fields. | |||||
CVE-2012-0931 | 1 Schneider-electric | 1 Modicon Quantum Plc | 2024-11-21 | 7.5 HIGH | 9.8 CRITICAL |
Schneider Electric Modicon Quantum PLC does not perform authentication between the Unity software and PLC, which allows remote attackers to cause a denial of service or possibly execute arbitrary code via unspecified vectors. | |||||
CVE-2012-0930 | 1 Schneider-electric | 1 Modicon Quantum Plc | 2024-11-21 | 4.3 MEDIUM | 6.1 MEDIUM |
Cross-site scripting (XSS) vulnerability in Schneider Electric Modicon Quantum PLC allows remote attackers to inject arbitrary web script or HTML via unspecified vectors. | |||||
CVE-2012-0929 | 1 Schneider-electric | 1 Modicon Quantum Plc | 2024-11-21 | 7.8 HIGH | 7.5 HIGH |
Multiple buffer overflows in Schneider Electric Modicon Quantum PLC allow remote attackers to cause a denial of service via malformed requests to the (1) FTP server or (2) HTTP server. | |||||
CVE-2011-5163 | 2 Mitsubishi-automation, Schneider-electric | 2 Mx4 Scada, Citectscada | 2024-11-21 | 4.6 MEDIUM | N/A |
Buffer overflow in an unspecified third-party component in the Batch module for Schneider Electric CitectSCADA before 7.20 and Mitsubishi MX4 SCADA before 7.20 allows local users to execute arbitrary code via a long string in a login sequence. | |||||
CVE-2011-4861 | 1 Schneider-electric | 3 Quantum Ethernet Module 140noe77100, Quantum Ethernet Module 140noe77101, Quantum Ethernet Module 140noe77111 | 2024-11-21 | 10.0 HIGH | N/A |
The modbus_125_handler function in the Schneider Electric Quantum Ethernet Module on the NOE 771 device (aka the Quantum 140NOE771* module) allows remote attackers to install arbitrary firmware updates via a MODBUS 125 function code to TCP port 502. | |||||
CVE-2011-4860 | 1 Schneider-electric | 3 Quantum Ethernet Module 140noe77100, Quantum Ethernet Module 140noe77101, Quantum Ethernet Module 140noe77111 | 2024-11-21 | 10.0 HIGH | N/A |
The ComputePassword function in the Schneider Electric Quantum Ethernet Module on the NOE 771 device (aka the Quantum 140NOE771* module) generates the password for the fwupgrade account by performing a calculation on the MAC address, which makes it easier for remote attackers to obtain access via a (1) ARP request message or (2) Neighbor Solicitation message. | |||||
CVE-2011-4859 | 1 Schneider-electric | 21 M340 Ethernet Module Bmxnoe0100, M340 Ethernet Module Bmxnoe0110, M340 Ethernet Module Bmxp342020 and 18 more | 2024-11-21 | 10.0 HIGH | N/A |
The Schneider Electric Quantum Ethernet Module, as used in the Quantum 140NOE771* and 140CPU65* modules, the Premium TSXETY* and TSXP57* modules, the M340 BMXNOE01* and BMXP3420* modules, and the STB DIO STBNIC2212 and STBNIP2* modules, uses hardcoded passwords for the (1) AUTCSE, (2) AUT_CSE, (3) fdrusers, (4) ftpuser, (5) loader, (6) nic2212, (7) nimrohs2212, (8) nip2212, (9) noe77111_v500, (10) ntpupdate, (11) pcfactory, (12) sysdiag, (13) target, (14) test, (15) USER, and (16) webserver accounts, which makes it easier for remote attackers to obtain access via the (a) TELNET, (b) Windriver Debug, or (c) FTP port. |