Vulnerabilities (CVE)

Filtered by CWE-319
Total 639 CVE
CVE Vendors Products Updated CVSS v2 CVSS v3
CVE-2020-10624 1 Honeywell 4 Controledge Plc, Controledge Plc Firmware, Controledge Rtu and 1 more 2024-11-21 5.0 MEDIUM 7.5 HIGH
ControlEdge PLC (R130.2, R140, R150, and R151) and RTU (R101, R110, R140, R150, and R151) exposes a session token on the network.
CVE-2020-10376 1 Technicolor 2 Tc7337net, Tc7337net Firmware 2024-11-21 5.0 MEDIUM 9.8 CRITICAL
Technicolor TC7337NET 08.89.17.23.03 devices allow remote attackers to discover passwords by sniffing the network for an "Authorization: Basic" HTTP header.
CVE-2020-10281 1 Dronecode 1 Micro Air Vehicle Link 2024-11-21 5.0 MEDIUM 7.5 HIGH
This vulnerability applies to the Micro Air Vehicle Link (MAVLink) protocol and allows a remote attacker to gain access to sensitive information provided it has access to the communication medium. MAVLink is a header-based protocol that does not perform encryption to improve transfer (and reception speed) and efficiency by design. The increasing popularity of the protocol (used accross different autopilots) has led to its use in wired and wireless mediums through insecure communication channels exposing sensitive information to a remote attacker with ability to intercept network traffic.
CVE-2020-10124 1 Ncr 2 Aptra Xfs, Selfserv Atm 2024-11-21 4.4 MEDIUM 7.1 HIGH
NCR SelfServ ATMs running APTRA XFS 05.01.00 do not encrypt, authenticate, or verify the integrity of messages between the BNA and the host computer, which could allow an attacker with physical access to the internal components of the ATM to execute arbitrary code, including code that enables the attacker to commit deposit forgery.
CVE-2020-0884 1 Microsoft 2 Visual Studio 2017, Visual Studio 2019 2024-11-21 4.3 MEDIUM 3.7 LOW
A spoofing vulnerability exists in Microsoft Visual Studio as it includes a reply URL that is not secured by SSL, aka 'Microsoft Visual Studio Spoofing Vulnerability'.
CVE-2019-9860 1 Abus 6 Secvest Wireless Alarm System Fuaa50000, Secvest Wireless Alarm System Fuaa50000 Firmware, Secvest Wireless Remote Control Fube50014 and 3 more 2024-11-21 5.0 MEDIUM 7.5 HIGH
Due to unencrypted signal communication and predictability of rolling codes, an attacker can "desynchronize" an ABUS Secvest wireless remote control (FUBE50014 or FUBE50015) relative to its controlled Secvest wireless alarm system FUAA50000 3.01.01, so that sent commands by the remote control are not accepted anymore.
CVE-2019-9532 1 Cobham 2 Explorer 710, Explorer 710 Firmware 2024-11-21 2.1 LOW 7.8 HIGH
The web application portal of the Cobham EXPLORER 710, firmware version 1.07, sends the login password in cleartext. This could allow an unauthenticated, local attacker to intercept the password and gain access to the portal.
CVE-2019-9101 1 Moxa 12 Mb3170, Mb3170 Firmware, Mb3180 and 9 more 2024-11-21 5.0 MEDIUM 7.5 HIGH
An issue was discovered on Moxa MGate MB3170 and MB3270 devices before 4.1, MB3280 and MB3480 devices before 3.1, MB3660 devices before 2.3, and MB3180 devices before 2.1. Sensitive information is sent to the web server in cleartext, which may allow an attacker to discover the credentials if they are able to observe traffic between the web browser and the server.
CVE-2019-8632 1 Apple 1 Texture 2024-11-21 4.0 MEDIUM 6.5 MEDIUM
Some analytics data was sent using HTTP rather than HTTPS. This was addressed by no longer sending this analytics data. This issue is fixed in Texture 5.11.10 for iOS, Texture 4.22.0.4 for Android. An attacker in a privileged network position may be able to intercept analytics data.
CVE-2019-8345 1 Estrongs 1 Es File Explorer File Manager 2024-11-21 4.3 MEDIUM 4.2 MEDIUM
The Help feature in the ES File Explorer File Manager application 4.1.9.7.4 for Android allows session hijacking by a Man-in-the-middle attacker on the local network because HTTPS is not used, and an attacker's web site is displayed in a WebView with no information about the URL.
CVE-2019-7675 1 Mobotix 2 S14, S14 Firmware 2024-11-21 5.0 MEDIUM 7.5 HIGH
An issue was discovered on MOBOTIX S14 MX-V4.2.1.61 devices. The default management application is delivered over cleartext HTTP with Basic Authentication, as demonstrated by the /admin/index.html URI.
CVE-2019-6846 1 Schneider-electric 8 Modicon 140cra, Modicon 140cra Firmware, Modicon Bmxcra and 5 more 2024-11-21 4.3 MEDIUM 6.5 MEDIUM
A CWE-319: Cleartext Transmission of Sensitive Information vulnerability exists in Modicon M580, Modicon M340, Modicon BMxCRA and 140CRA modules (all firmware versions), which could cause information disclosure when using the FTP protocol.
CVE-2019-6845 1 Schneider-electric 46 Modicon M340, Modicon M340 Firmware, Modicon M580 and 43 more 2024-11-21 5.0 MEDIUM 7.5 HIGH
A CWE-319: Cleartext Transmission of Sensitive Information vulnerability exists in Modicon M580, Modicon M340, Modicon Premium , Modicon Quantum (all firmware versions), which could cause the disclosure of information when transferring applications to the controller using Modbus TCP protocol.
CVE-2019-6652 1 F5 1 Big-iq Centralized Management 2024-11-21 6.4 MEDIUM 6.5 MEDIUM
In BIG-IQ 6.0.0-6.1.0, services for stats do not require authentication nor do they implement any form of Transport Layer Security (TLS).
CVE-2019-6640 1 F5 13 Big-ip Access Policy Manager, Big-ip Advanced Firewall Manager, Big-ip Analytics and 10 more 2024-11-21 5.0 MEDIUM 5.3 MEDIUM
On BIG-IP 14.1.0-14.1.0.5, 14.0.0-14.0.0.4, 13.0.0-13.1.1.4, 12.1.0-12.1.4, 11.6.1-11.6.3.4, and 11.5.1-11.5.8, SNMP exposes sensitive configuration objects over insecure transmission channels. This issue is exposed when a passphrase is inserted into various profile types and accessed using SNMPv2.
CVE-2019-6613 1 F5 13 Big-ip Access Policy Manager, Big-ip Advanced Firewall Manager, Big-ip Analytics and 10 more 2024-11-21 5.0 MEDIUM 5.3 MEDIUM
On BIG-IP 13.0.0-13.1.1.4, 12.1.0-12.1.4, 11.6.1-11.6.3.4, and 11.5.2-11.5.8, SNMP may expose sensitive configuration objects over insecure transmission channels. This issue is exposed when a passphrase is used with various profile types and is accessed using SNMPv2.
CVE-2019-6540 1 Medtronic 46 Amplia Crt-d, Amplia Crt-d Firmware, Carelink 2090 and 43 more 2024-11-21 3.3 LOW 6.5 MEDIUM
The Conexus telemetry protocol utilized within Medtronic MyCareLink Monitor versions 24950 and 24952, CareLink Monitor version 2490C, CareLink 2090 Programmer, Amplia CRT-D, Claria CRT-D, Compia CRT-D, Concerto CRT-D, Concerto II CRT-D, Consulta CRT-D, Evera ICD, Maximo II CRT-D and ICD, Mirro ICD, Nayamed ND ICD, Primo ICD, Protecta ICD and CRT-D, Secura ICD, Virtuoso ICD, Virtuoso II ICD, Visia AF ICD, and Viva CRT-D does not implement encryption. An attacker with adjacent short-range access to a target product can listen to communications, including the transmission of sensitive data.
CVE-2019-6526 1 Moxa 8 Eds-405a, Eds-405a Firmware, Eds-408a and 5 more 2024-11-21 5.0 MEDIUM 9.8 CRITICAL
Moxa IKS-G6824A series Versions 4.5 and prior, EDS-405A series Version 3.8 and prior, EDS-408A series Version 3.8 and prior, and EDS-510A series Version 3.8 and prior use plaintext transmission of sensitive data, which may allow an attacker to capture sensitive data such as an administrative password.
CVE-2019-5635 1 Belwith-keeler 2 Hickory Smart Ethernet Bridge, Hickory Smart Ethernet Bridge Firmware 2024-11-21 5.0 MEDIUM 7.5 HIGH
A cleartext transmission of sensitive information vulnerability is present in Hickory Smart Ethernet Bridge from Belwith Products, LLC. Captured data reveals that the Hickory Smart Ethernet Bridge device communicates over the network to an MQTT broker without using encryption. This exposed the default username and password used to authenticate to the MQTT broker. This issue affects Hickory Smart Ethernet Bridge, model number H077646. The firmware does not appear to contain versioning information.
CVE-2019-5505 1 Netapp 1 Ontap Select Deploy Administration Utility 2024-11-21 5.0 MEDIUM 9.8 CRITICAL
ONTAP Select Deploy administration utility versions 2.2 through 2.12.1 transmit credentials in plaintext.