Filtered by vendor Honeywell
Subscribe
Total
88 CVE
CVE | Vendors | Products | Updated | CVSS v2 | CVSS v3 |
---|---|---|---|---|---|
CVE-2018-8714 | 1 Honeywell | 1 Matrikonopc Explorer | 2024-11-21 | 3.6 LOW | 6.1 MEDIUM |
Honeywell MatrikonOPC OPC Controller before 5.1.0.0 allows local users to transfer arbitrary files from a host computer and consequently obtain sensitive information via vectors related to MSXML libraries. | |||||
CVE-2017-5671 | 1 Honeywell | 14 Intermec Pc23, Intermec Pc23 Firmware, Intermec Pc42 and 11 more | 2024-11-21 | 7.2 HIGH | 8.8 HIGH |
Honeywell Intermec PM23, PM42, PM43, PC23, PC43, PD43, and PC42 industrial printers before 10.11.013310 and 10.12.x before 10.12.013309 have /usr/bin/lua installed setuid to the itadmin account, which allows local users to conduct a BusyBox jailbreak attack and obtain root privileges by overwriting the /etc/shadow file. | |||||
CVE-2017-5143 | 1 Honeywell | 1 Xl Web Ii Controller | 2024-11-21 | 7.5 HIGH | 8.6 HIGH |
An issue was discovered in Honeywell XL Web II controller XL1000C500 XLWebExe-2-01-00 and prior, and XLWeb 500 XLWebExe-1-02-08 and prior. A user without authenticating can make a directory traversal attack by accessing a specific URL. | |||||
CVE-2017-5142 | 1 Honeywell | 1 Xl Web Ii Controller | 2024-11-21 | 6.5 MEDIUM | 9.1 CRITICAL |
An issue was discovered in Honeywell XL Web II controller XL1000C500 XLWebExe-2-01-00 and prior, and XLWeb 500 XLWebExe-1-02-08 and prior. A user with low privileges is able to open and change the parameters by accessing a specific URL because of Improper Privilege Management. | |||||
CVE-2017-5141 | 1 Honeywell | 1 Xl Web Ii Controller | 2024-11-21 | 6.5 MEDIUM | 6.0 MEDIUM |
An issue was discovered in Honeywell XL Web II controller XL1000C500 XLWebExe-2-01-00 and prior, and XLWeb 500 XLWebExe-1-02-08 and prior. An attacker can establish a new user session, without invalidating any existing session identifier, which gives the opportunity to steal authenticated sessions (SESSION FIXATION). | |||||
CVE-2017-5140 | 1 Honeywell | 1 Xl Web Ii Controller | 2024-11-21 | 5.0 MEDIUM | 9.8 CRITICAL |
An issue was discovered in Honeywell XL Web II controller XL1000C500 XLWebExe-2-01-00 and prior, and XLWeb 500 XLWebExe-1-02-08 and prior. Password is stored in clear text. | |||||
CVE-2017-5139 | 1 Honeywell | 1 Xl Web Ii Controller | 2024-11-21 | 5.0 MEDIUM | 9.8 CRITICAL |
An issue was discovered in Honeywell XL Web II controller XL1000C500 XLWebExe-2-01-00 and prior, and XLWeb 500 XLWebExe-1-02-08 and prior. Any user is able to disclose a password by accessing a specific URL, because of Plaintext Storage of a Password. | |||||
CVE-2017-14263 | 1 Honeywell | 14 Enterprise Dvr, Enterprise Dvr Firmware, Fusion Iv Rev C and 11 more | 2024-11-21 | 9.3 HIGH | 8.1 HIGH |
Honeywell NVR devices allow remote attackers to create a user account in the admin group by leveraging access to a guest account to obtain a session ID, and then sending that session ID in a userManager.addUser request to the /RPC2 URI. The attacker can login to the device with that new user account to fully control the device. | |||||
CVE-2016-8344 | 1 Honeywell | 1 Experion Process Knowledge System | 2024-11-21 | 4.3 MEDIUM | 3.7 LOW |
An issue was discovered in Honeywell Experion Process Knowledge System (PKS) platform: Experion PKS, Release 3xx and prior, Experion PKS, Release 400, Experion PKS, Release 410, Experion PKS, Release 430, and Experion PKS, Release 431. Experion PKS does not properly validate input. By sending a specially crafted packet, an attacker could cause the process to terminate. A successful exploit would prevent firmware uploads to the Series-C devices. | |||||
CVE-2016-2280 | 1 Honeywell | 1 Uniformance Process History Database | 2024-11-21 | 7.8 HIGH | 7.5 HIGH |
Buffer overflow in RDISERVER in Honeywell Uniformance Process History Database (PHD) R310, R320, and R321 allows remote attackers to cause a denial of service (service outage) via unspecified vectors. | |||||
CVE-2015-7908 | 1 Honeywell | 4 Midas, Midas Black, Midas Black Firmware and 1 more | 2024-11-21 | 9.3 HIGH | N/A |
Honeywell Midas gas detectors before 1.13b3 and Midas Black gas detectors before 2.13b3 allow remote attackers to discover cleartext passwords by sniffing the network. | |||||
CVE-2015-7907 | 1 Honeywell | 2 Midas Black Firmware, Midas Firmware | 2024-11-21 | 6.4 MEDIUM | 8.6 HIGH |
Directory traversal vulnerability in the web server on Honeywell Midas gas detectors before 1.13b3 and Midas Black gas detectors before 2.13b3 allows remote attackers to bypass authentication, and write to a configuration file or trigger a calibration or test, via unspecified vectors. | |||||
CVE-2015-2848 | 1 Honeywell | 1 Tuxedo Touch | 2024-11-21 | 6.8 MEDIUM | N/A |
Cross-site request forgery (CSRF) vulnerability in Honeywell Tuxedo Touch before 5.2.19.0_VA allows remote attackers to hijack the authentication of arbitrary users for requests associated with home-automation commands, as demonstrated by a door-unlock command. | |||||
CVE-2015-2847 | 1 Honeywell | 1 Tuxedo Touch | 2024-11-21 | 5.0 MEDIUM | N/A |
Honeywell Tuxedo Touch before 5.2.19.0_VA relies on client-side authentication involving JavaScript, which allows remote attackers to bypass intended access restrictions by removing USERACCT requests from the client-server data stream. | |||||
CVE-2015-0984 | 1 Honeywell | 8 Excel Web Xl 1000c1000 600 I\/o, Excel Web Xl 1000c1000 600 I\/o Uukl, Excel Web Xl 1000c100 104 I\/o and 5 more | 2024-11-21 | 10.0 HIGH | N/A |
Directory traversal vulnerability in the FTP server on Honeywell Excel Web XL1000C50 52 I/O, XL1000C100 104 I/O, XL1000C500 300 I/O, XL1000C1000 600 I/O, XL1000C50U 52 I/O UUKL, XL1000C100U 104 I/O UUKL, XL1000C500U 300 I/O UUKL, and XL1000C1000U 600 I/O UUKL controllers before 2.04.01 allows remote attackers to read files under the web root, and consequently obtain administrative login access, via a crafted pathname. | |||||
CVE-2014-8269 | 1 Honeywell | 1 Opos Suite | 2024-11-21 | 7.5 HIGH | N/A |
Multiple stack-based buffer overflows in (1) HWOPOSScale.ocx and (2) HWOPOSSCANNER.ocx in Honeywell OPOS Suite before 1.13.4.15 allow remote attackers to execute arbitrary code via a crafted file that is improperly handled by the Open method. | |||||
CVE-2014-3110 | 1 Honeywell | 2 Falcon Xlweb Linux Controller, Falcon Xlweb Xlwebexe | 2024-11-21 | 4.3 MEDIUM | N/A |
Multiple cross-site scripting (XSS) vulnerabilities on Honeywell FALCON XLWeb Linux controller devices 2.04.01 and earlier and FALCON XLWeb XLWebExe controller devices 2.02.11 and earlier allow remote attackers to inject arbitrary web script or HTML via invalid input. | |||||
CVE-2014-2717 | 1 Honeywell | 2 Falcon Xlweb Linux Controller, Falcon Xlweb Xlwebexe | 2024-11-21 | 7.6 HIGH | N/A |
Honeywell FALCON XLWeb Linux controller devices 2.04.01 and earlier and FALCON XLWeb XLWebExe controller devices 2.02.11 and earlier allow remote attackers to bypass authentication and obtain administrative access by visiting the change-password page. | |||||
CVE-2013-0108 | 1 Honeywell | 3 Comfortpoint Open Manager Station, Enterprise Buildings Integrator, Symmetre | 2024-11-21 | 6.8 MEDIUM | N/A |
An ActiveX control in HscRemoteDeploy.dll in Honeywell Enterprise Buildings Integrator (EBI) R310, R400.2, R410.1, and R410.2; SymmetrE R310, R410.1, and R410.2; ComfortPoint Open Manager (aka CPO-M) Station R100; and HMIWeb Browser client packages allows remote attackers to execute arbitrary code via a crafted HTML document. | |||||
CVE-2012-0254 | 1 Honeywell | 3 Enterprise Building Manager, Experion, Symmetre | 2024-11-21 | 7.5 HIGH | N/A |
Stack-based buffer overflow in the HMIWeb Browser HSCDSPRenderDLL ActiveX control in Honeywell Process Solutions (HPS) Experion R2xx, R30x, R31x, and R400.x; Honeywell Building Solutions (HBS) Enterprise Building Manager R400 and R410.1; and Honeywell Environmental Combustion and Controls (ECC) SymmetrE R410.1 allows remote attackers to execute arbitrary code via unspecified vectors. |