CVE Vendors Products Updated CVSS v2 CVSS v3
CVE-2021-27387 1 Siemens 1 Simcenter Femap 2024-02-28 6.8 MEDIUM 7.8 HIGH
A vulnerability has been identified in Simcenter Femap 2020.2 (All versions < V2020.2.MP3), Simcenter Femap 2021.1 (All versions < V2021.1.MP3). The femap.exe application lacks proper validation of user-supplied data when parsing FEMAP files. This could result in an out of bounds write past the end of an allocated structure, a different vulnerability than CVE-2021-27399. An attacker could leverage this vulnerability to execute code in the context of the current process. (ZDI-CAN-12819)
CVE-2021-34319 1 Siemens 2 Jt2go, Teamcenter Visualization 2024-02-28 6.8 MEDIUM 7.8 HIGH
A vulnerability has been identified in JT2Go (All versions < V13.2), Teamcenter Visualization (All versions < V13.2). The BMP_loader.dll library in affected applications lacks proper validation of user-supplied data when parsing SGI files. This could result in an out of bounds write past the end of an allocated structure. An attacker could leverage this vulnerability to execute code in the context of the current process. (ZDI-CAN-13404)
CVE-2020-26144 3 Arista, Samsung, Siemens 36 C-100, C-100 Firmware, C-110 and 33 more 2024-02-28 3.3 LOW 6.5 MEDIUM
An issue was discovered on Samsung Galaxy S3 i9305 4.4.4 devices. The WEP, WPA, WPA2, and WPA3 implementations accept plaintext A-MSDU frames as long as the first 8 bytes correspond to a valid RFC1042 (i.e., LLC/SNAP) header for EAPOL. An adversary can abuse this to inject arbitrary network packets independent of the network configuration.
CVE-2021-25158 2 Arubanetworks, Siemens 3 Instant, Scalance W1750d, Scalance W1750d Firmware 2024-02-28 4.3 MEDIUM 5.9 MEDIUM
A remote arbitrary file read vulnerability was discovered in some Aruba Instant Access Point (IAP) products in version(s): Aruba Instant 6.5.x: 6.5.4.18 and below; Aruba Instant 8.3.x: 8.3.0.14 and below; Aruba Instant 8.5.x: 8.5.0.11 and below; Aruba Instant 8.6.x: 8.6.0.7 and below; Aruba Instant 8.7.x: 8.7.1.1 and below. Aruba has released patches for Aruba Instant that address this security vulnerability.
CVE-2021-34329 1 Siemens 3 Jt2go, Solid Edge, Teamcenter Visualization 2024-02-28 6.8 MEDIUM 7.8 HIGH
A vulnerability has been identified in JT2Go (All versions < V13.2), Solid Edge SE2021 (All Versions < SE2021MP5), Teamcenter Visualization (All versions < V13.2). The plmxmlAdapterSE70.dll library in affected applications lacks proper validation of user-supplied data when parsing PAR files. This could result in an out of bounds write past the fixed-length heap-based buffer. An attacker could leverage this vulnerability to execute code in the context of the current process. (ZDI-CAN-13427)
CVE-2021-37725 2 Arubanetworks, Siemens 4 Arubaos, Sd-wan, Scalance W1750d and 1 more 2024-02-28 8.8 HIGH 8.1 HIGH
A remote cross-site request forgery (csrf) vulnerability was discovered in Aruba SD-WAN Software and Gateways; Aruba Operating System Software version(s): Prior to 8.6.0.4-2.2.0.4; Prior to 8.8.0.1, 8.7.1.2, 8.6.0.8, 8.5.0.12, 8.3.0.15. Aruba has released patches for Aruba SD-WAN Software and Gateways and ArubaOS that address this security vulnerability.
CVE-2021-34326 1 Siemens 3 Jt2go, Solid Edge, Teamcenter Visualization 2024-02-28 6.8 MEDIUM 7.8 HIGH
A vulnerability has been identified in JT2Go (All versions < V13.2), Solid Edge SE2021 (All Versions < SE2021MP5), Teamcenter Visualization (All versions < V13.2). The plmxmlAdapterSE70.dll library in affected applications lacks proper validation of user-supplied data when parsing PAR files. This could result in an out of bounds write past the fixed-length heap-based buffer. An attacker could leverage this vulnerability to execute code in the context of the current process. (ZDI-CAN-13422)
CVE-2021-22940 5 Debian, Netapp, Nodejs and 2 more 7 Debian Linux, Nextgen Api, Node.js and 4 more 2024-02-28 5.0 MEDIUM 7.5 HIGH
Node.js before 16.6.1, 14.17.5, and 12.22.5 is vulnerable to a use after free attack where an attacker might be able to exploit the memory corruption, to change process behavior.
CVE-2021-34302 1 Siemens 2 Jt2go, Teamcenter Visualization 2024-02-28 4.3 MEDIUM 5.5 MEDIUM
A vulnerability has been identified in JT2Go (All versions < V13.2), Teamcenter Visualization (All versions < V13.2). The BMP_Loader.dll library in affected applications lacks proper validation of user-supplied data when parsing BMP files. This could result in an out of bounds read past the end of an allocated buffer. An attacker could leverage this vulnerability to leak information in the context of the current process. (ZDI-CAN-13197)
CVE-2020-27009 1 Siemens 2 Nucleus Net, Nucleus Source Code 2024-02-28 6.8 MEDIUM 8.1 HIGH
A vulnerability has been identified in APOGEE PXC Compact (BACnet) (All versions < V3.5.5), APOGEE PXC Compact (P2 Ethernet) (All versions < V2.8.20), APOGEE PXC Modular (BACnet) (All versions < V3.5.5), APOGEE PXC Modular (P2 Ethernet) (All versions < V2.8.20), Nucleus NET (All versions < V5.2), Nucleus Source Code (Versions including affected DNS modules), TALON TC Compact (BACnet) (All versions < V3.5.5), TALON TC Modular (BACnet) (All versions < V3.5.5). The DNS domain name record decompression functionality does not properly validate the pointer offset values. The parsing of malformed responses could result in a write past the end of an allocated structure. An attacker with a privileged position in the network could leverage this vulnerability to execute code in the context of the current process or cause a denial-of-service condition.
CVE-2021-34294 1 Siemens 2 Jt2go, Teamcenter Visualization 2024-02-28 6.8 MEDIUM 7.8 HIGH
A vulnerability has been identified in JT2Go (All versions < V13.2), Teamcenter Visualization (All versions < V13.2). The Gif_loader.dll library in affected applications lacks proper validation of user-supplied data when parsing GIF files. This could result in an out of bounds read past the end of an allocated buffer. An attacker could leverage this vulnerability to execute code in the context of the current process. (ZDI-CAN-13023
CVE-2021-32804 3 Oracle, Siemens, Tar Project 3 Graalvm, Sinec Infrastructure Network Services, Tar 2024-02-28 5.8 MEDIUM 8.1 HIGH
The npm package "tar" (aka node-tar) before versions 6.1.1, 5.0.6, 4.4.14, and 3.3.2 has a arbitrary File Creation/Overwrite vulnerability due to insufficient absolute path sanitization. node-tar aims to prevent extraction of absolute file paths by turning absolute paths into relative paths when the `preservePaths` flag is not set to `true`. This is achieved by stripping the absolute path root from any absolute file paths contained in a tar file. For example `/home/user/.bashrc` would turn into `home/user/.bashrc`. This logic was insufficient when file paths contained repeated path roots such as `////home/user/.bashrc`. `node-tar` would only strip a single path root from such paths. When given an absolute file path with repeating path roots, the resulting path (e.g. `///home/user/.bashrc`) would still resolve to an absolute path, thus allowing arbitrary file creation and overwrite. This issue was addressed in releases 3.2.2, 4.4.14, 5.0.6 and 6.1.1. Users may work around this vulnerability without upgrading by creating a custom `onentry` method which sanitizes the `entry.path` or a `filter` method which removes entries with absolute paths. See referenced GitHub Advisory for details. Be aware of CVE-2021-32803 which fixes a similar bug in later versions of tar.
CVE-2020-24513 3 Debian, Intel, Siemens 71 Debian Linux, Atom C3308, Atom C3336 and 68 more 2024-02-28 2.1 LOW 6.5 MEDIUM
Domain-bypass transient execution vulnerability in some Intel Atom(R) Processors may allow an authenticated user to potentially enable information disclosure via local access.
CVE-2021-34297 1 Siemens 2 Jt2go, Teamcenter Visualization 2024-02-28 6.8 MEDIUM 7.8 HIGH
A vulnerability has been identified in JT2Go (All versions < V13.2), Teamcenter Visualization (All versions < V13.2). The BMP_Loader.dll library in affected applications lacks proper validation of user-supplied data when parsing BMP files. This could result in an out of bounds write past the end of an allocated structure. An attacker could leverage this vulnerability to execute code in the context of the current process. (ZDI-CAN-13059)
CVE-2020-7461 2 Freebsd, Siemens 5 Freebsd, Simatic Rf350m, Simatic Rf350m Firmware and 2 more 2024-02-28 7.5 HIGH 7.3 HIGH
In FreeBSD 12.1-STABLE before r365010, 11.4-STABLE before r365011, 12.1-RELEASE before p9, 11.4-RELEASE before p3, and 11.3-RELEASE before p13, dhclient(8) fails to handle certain malformed input related to handling of DHCP option 119 resulting a heap overflow. The heap overflow could in principle be exploited to achieve remote code execution. The affected process runs with reduced privileges in a Capsicum sandbox, limiting the immediate impact of an exploit.
CVE-2021-25161 2 Arubanetworks, Siemens 3 Instant, Scalance W1750d, Scalance W1750d Firmware 2024-02-28 4.3 MEDIUM 6.1 MEDIUM
A remote cross-site scripting (xss) vulnerability was discovered in some Aruba Instant Access Point (IAP) products in version(s): Aruba Instant 6.4.x: 6.4.4.8-4.2.4.17 and below; Aruba Instant 6.5.x: 6.5.4.18 and below; Aruba Instant 8.3.x: 8.3.0.14 and below; Aruba Instant 8.5.x: 8.5.0.11 and below; Aruba Instant 8.6.x: 8.6.0.7 and below; Aruba Instant 8.7.x: 8.7.1.1 and below. Aruba has released patches for Aruba Instant that address this security vulnerability.
CVE-2021-37729 2 Arubanetworks, Siemens 4 Arubaos, Sd-wan, Scalance W1750d and 1 more 2024-02-28 5.5 MEDIUM 6.5 MEDIUM
A remote path traversal vulnerability was discovered in Aruba SD-WAN Software and Gateways; Aruba Operating System Software version(s): Prior to 8.6.0.0-2.2.0.4; Prior to 8.7.1.3, 8.6.0.9, 8.5.0.12, 8.3.0.16, 6.5.4.19, 6.4.4.25. Aruba has released patches for Aruba SD-WAN Software and Gateways and ArubaOS that address this security vulnerability.
CVE-2021-34311 1 Siemens 2 Jt2go, Teamcenter Visualization 2024-02-28 6.8 MEDIUM 7.8 HIGH
A vulnerability has been identified in JT2Go (All versions < V13.2), Teamcenter Visualization (All versions < V13.2). The Mono_loader.dll library in affected applications lacks proper validation of user-supplied data when parsing J2K files. This could result in an out of bounds write past the end of an allocated structure. An attacker could leverage this vulnerability to execute code in the context of the current process. (ZDI-CAN-13352)
CVE-2020-24507 2 Intel, Siemens 409 B150, B250, B360 and 406 more 2024-02-28 2.1 LOW 4.4 MEDIUM
Improper initialization in a subsystem in the Intel(R) CSME versions before 11.8.86, 11.12.86, 11.22.86, 12.0.81, 13.0.47, 13.30.17, 14.1.53, 14.5.32, 13.50.11 and 15.0.22 may allow a privileged user to potentially enable information disclosure via local access.
CVE-2021-25217 5 Debian, Fedoraproject, Isc and 2 more 26 Debian Linux, Fedora, Dhcp and 23 more 2024-02-28 3.3 LOW 7.4 HIGH
In ISC DHCP 4.1-ESV-R1 -> 4.1-ESV-R16, ISC DHCP 4.4.0 -> 4.4.2 (Other branches of ISC DHCP (i.e., releases in the 4.0.x series or lower and releases in the 4.3.x series) are beyond their End-of-Life (EOL) and no longer supported by ISC. From inspection it is clear that the defect is also present in releases from those series, but they have not been officially tested for the vulnerability), The outcome of encountering the defect while reading a lease that will trigger it varies, according to: the component being affected (i.e., dhclient or dhcpd) whether the package was built as a 32-bit or 64-bit binary whether the compiler flag -fstack-protection-strong was used when compiling In dhclient, ISC has not successfully reproduced the error on a 64-bit system. However, on a 32-bit system it is possible to cause dhclient to crash when reading an improper lease, which could cause network connectivity problems for an affected system due to the absence of a running DHCP client process. In dhcpd, when run in DHCPv4 or DHCPv6 mode: if the dhcpd server binary was built for a 32-bit architecture AND the -fstack-protection-strong flag was specified to the compiler, dhcpd may exit while parsing a lease file containing an objectionable lease, resulting in lack of service to clients. Additionally, the offending lease and the lease immediately following it in the lease database may be improperly deleted. if the dhcpd server binary was built for a 64-bit architecture OR if the -fstack-protection-strong compiler flag was NOT specified, the crash will not occur, but it is possible for the offending lease and the lease which immediately followed it to be improperly deleted.