Vulnerabilities (CVE)

Filtered by vendor Siemens Subscribe
Total 1853 CVE
CVE Vendors Products Updated CVSS v2 CVSS v3
CVE-2020-15795 1 Siemens 2 Nucleus Net, Nucleus Source Code 2024-02-28 6.8 MEDIUM 8.1 HIGH
A vulnerability has been identified in APOGEE PXC Compact (BACnet) (All versions < V3.5.5), APOGEE PXC Compact (P2 Ethernet) (All versions < V2.8.20), APOGEE PXC Modular (BACnet) (All versions < V3.5.5), APOGEE PXC Modular (P2 Ethernet) (All versions < V2.8.20), Nucleus NET (All versions < V5.2), Nucleus Source Code (Versions including affected DNS modules), TALON TC Compact (BACnet) (All versions < V3.5.5), TALON TC Modular (BACnet) (All versions < V3.5.5). The DNS domain name label parsing functionality does not properly validate the names in DNS-responses. The parsing of malformed responses could result in a write past the end of an allocated structure. An attacker with a privileged position in the network could leverage this vulnerability to execute code in the context of the current process or cause a denial-of-service condition.
CVE-2021-25670 1 Siemens 1 Tecnomatix Robotexpert 2024-02-28 6.8 MEDIUM 7.8 HIGH
A vulnerability has been identified in Tecnomatix RobotExpert (All versions < V16.1). Affected applications lack proper validation of user-supplied data when parsing CELL files. This could result in an out of bounds write past the end of an allocated structure. An attacker could leverage this vulnerability to execute code in the context of the current process. (ZDI-CAN-12608)
CVE-2020-12360 3 Intel, Netapp, Siemens 552 Bios, Core I3-l13g4, Core I5-l16g7 and 549 more 2024-02-28 4.6 MEDIUM 7.8 HIGH
Out of bounds read in the firmware for some Intel(R) Processors may allow an authenticated user to potentially enable escalation of privilege via local access.
CVE-2021-32948 2 Opendesign, Siemens 4 Drawings Sdk, Comos, Jt2go and 1 more 2024-02-28 6.8 MEDIUM 7.8 HIGH
An out-of-bounds write issue exists in the DWG file-reading procedure in the Drawings SDK (All versions prior to 2022.4) resulting from the lack of proper validation of user-supplied data. This can result in a write past the end of an allocated buffer and allow attackers to cause a denial-of-service condition or execute code in the context of the current process.
CVE-2020-28397 1 Siemens 111 Cpu1510sp F-1, Cpu1510sp F-1 Firmware, Cpu 1211c and 108 more 2024-02-28 5.0 MEDIUM 5.3 MEDIUM
A vulnerability has been identified in SIMATIC Drive Controller family (All versions < V2.9.2), SIMATIC ET 200SP Open Controller CPU 1515SP PC2 (incl. SIPLUS variants) (All versions < V21.9), SIMATIC S7 PLCSIM Advanced (All versions > V2 < V4), SIMATIC S7-1200 CPU family (incl. SIPLUS variants) (Version V4.4), SIMATIC S7-1500 CPU family (incl. related ET200 CPUs and SIPLUS variants) (All versions > V2.5 < V2.9.2), SIMATIC S7-1500 Software Controller (All versions > V2.5 < V21.9), TIM 1531 IRC (incl. SIPLUS NET variants) (Version V2.1). Due to an incorrect authorization check in the affected component, an attacker could extract information about access protected PLC program variables over port 102/tcp from an affected device when reading multiple attributes at once.
CVE-2021-34327 1 Siemens 3 Jt2go, Solid Edge, Teamcenter Visualization 2024-02-28 6.8 MEDIUM 7.8 HIGH
A vulnerability has been identified in JT2Go (All versions < V13.2), Solid Edge SE2021 (All Versions < SE2021MP5), Teamcenter Visualization (All versions < V13.2). The plmxmlAdapterSE70.dll library in affected applications lacks proper validation of user-supplied data when parsing ASM files. This could result in an out of bounds write past the fixed-length heap-based buffer. An attacker could leverage this vulnerability to execute code in the context of the current process. (ZDI-CAN-13423)
CVE-2021-37717 2 Arubanetworks, Siemens 4 Arubaos, Sd-wan, Scalance W1750d and 1 more 2024-02-28 9.0 HIGH 7.2 HIGH
A remote arbitrary command execution vulnerability was discovered in Aruba SD-WAN Software and Gateways; Aruba Operating System Software version(s): Prior to 8.6.0.4-2.2.0.6; Prior to 8.7.1.4, 8.6.0.7, 8.5.0.12, 8.3.0.16. Aruba has released patches for Aruba SD-WAN Software and Gateways and ArubaOS that address this security vulnerability.
CVE-2020-24486 3 Intel, Netapp, Siemens 548 Bios, Core I3-l13g4, Core I5-l16g7 and 545 more 2024-02-28 2.1 LOW 5.5 MEDIUM
Improper input validation in the firmware for some Intel(R) Processors may allow an authenticated user to potentially enable denial of service via local access.
CVE-2019-5317 2 Arubanetworks, Siemens 3 Instant, Scalance W1750d, Scalance W1750d Firmware 2024-02-28 4.6 MEDIUM 6.8 MEDIUM
A local authentication bypass vulnerability was discovered in some Aruba Instant Access Point (IAP) products in version(s): Aruba Instant 6.4.x: 6.4.4.8-4.2.4.18 and below; Aruba Instant 6.5.x: 6.5.4.15 and below; Aruba Instant 8.3.x: 8.3.0.11 and below; Aruba Instant 8.4.x: 8.4.0.5 and below; Aruba Instant 8.5.x: 8.5.0.6 and below; Aruba Instant 8.6.x: 8.6.0.2 and below. Aruba has released patches for Aruba Instant that address this security vulnerability.
CVE-2021-25664 1 Siemens 5 Capital Vstar, Nucleus Net, Nucleus Readystart V3 and 2 more 2024-02-28 5.0 MEDIUM 7.5 HIGH
A vulnerability has been identified in Capital Embedded AR Classic 431-422 (All versions), Capital Embedded AR Classic R20-11 (All versions < V2303), Nucleus NET (All versions), Nucleus ReadyStart V3 (All versions < V2017.02.4), Nucleus ReadyStart V4 (All versions < V4.1.0), Nucleus Source Code (All versions including affected IPv6 stack). The function that processes the Hop-by-Hop extension header in IPv6 packets and its options lacks any checks against the length field of the header, allowing attackers to put the function into an infinite loop by supplying arbitrary length values.
CVE-2021-25660 1 Siemens 19 Simatic Hmi Comfort Outdoor Panels 15\", Simatic Hmi Comfort Outdoor Panels 15\" Firmware, Simatic Hmi Comfort Outdoor Panels 7\" and 16 more 2024-02-28 5.0 MEDIUM 7.5 HIGH
A vulnerability has been identified in SIMATIC HMI Comfort Outdoor Panels V15 7\" & 15\" (incl. SIPLUS variants) (All versions < V15.1 Update 6), SIMATIC HMI Comfort Outdoor Panels V16 7\" & 15\" (incl. SIPLUS variants) (All versions < V16 Update 4), SIMATIC HMI Comfort Panels V15 4\" - 22\" (incl. SIPLUS variants) (All versions < V15.1 Update 6), SIMATIC HMI Comfort Panels V16 4\" - 22\" (incl. SIPLUS variants) (All versions < V16 Update 4), SIMATIC HMI KTP Mobile Panels V15 KTP400F, KTP700, KTP700F, KTP900 and KTP900F (All versions < V15.1 Update 6), SIMATIC HMI KTP Mobile Panels V16 KTP400F, KTP700, KTP700F, KTP900 and KTP900F (All versions < V16 Update 4), SIMATIC WinCC Runtime Advanced V15 (All versions < V15.1 Update 6), SIMATIC WinCC Runtime Advanced V16 (All versions < V16 Update 4). SmartVNC has an out-of-bounds memory access vulnerability that could be triggered on the server side when sending data from the client, which could result in a Denial-of-Service condition.
CVE-2021-37722 2 Arubanetworks, Siemens 4 Arubaos, Sd-wan, Scalance W1750d and 1 more 2024-02-28 9.0 HIGH 7.2 HIGH
A remote arbitrary command execution vulnerability was discovered in Aruba SD-WAN Software and Gateways; Aruba Operating System Software version(s): Prior to 8.6.0.4-2.2.0.4; Prior to 8.7.1.4, 8.6.0.9, 8.5.0.13, 8.3.0.16, 6.5.4.20, 6.4.4.25. Aruba has released patches for Aruba SD-WAN Software and Gateways and ArubaOS that address this security vulnerability.
CVE-2021-36221 5 Debian, Fedoraproject, Golang and 2 more 6 Debian Linux, Fedora, Go and 3 more 2024-02-28 4.3 MEDIUM 5.9 MEDIUM
Go before 1.15.15 and 1.16.x before 1.16.7 has a race condition that can lead to a net/http/httputil ReverseProxy panic upon an ErrAbortHandler abort.
CVE-2020-27737 1 Siemens 6 Nucleus Net, Nucleus Readystart V3, Nucleus Readystart V4 and 3 more 2024-02-28 5.8 MEDIUM 6.5 MEDIUM
A vulnerability has been identified in APOGEE PXC Compact (BACnet) (All versions < V3.5.5), APOGEE PXC Compact (P2 Ethernet) (All versions < V2.8.20), APOGEE PXC Modular (BACnet) (All versions < V3.5.5), APOGEE PXC Modular (P2 Ethernet) (All versions < V2.8.20), Nucleus NET (All versions), Nucleus ReadyStart V3 (All versions < V2017.02.3), Nucleus ReadyStart V4 (All versions < V4.1.0), Nucleus Source Code (Versions including affected DNS modules), SIMOTICS CONNECT 400 (All versions < V0.5.0.0), TALON TC Compact (BACnet) (All versions < V3.5.5), TALON TC Modular (BACnet) (All versions < V3.5.5). The DNS response parsing functionality does not properly validate various length and counts of the records. The parsing of malformed responses could result in a read past the end of an allocated structure. An attacker with a privileged position in the network could leverage this vulnerability to cause a denial-of-service condition or leak the memory past the allocated structure.
CVE-2021-25669 1 Siemens 58 Scalance X200-4p Irt, Scalance X200-4p Irt Firmware, Scalance X201-3p Irt and 55 more 2024-02-28 7.5 HIGH 9.8 CRITICAL
A vulnerability has been identified in SCALANCE X200-4P IRT (All versions < 5.5.1), SCALANCE X201-3P IRT (All versions < 5.5.1), SCALANCE X201-3P IRT PRO (All versions < 5.5.1), SCALANCE X202-2 IRT (All versions < 5.5.1), SCALANCE X202-2P IRT (incl. SIPLUS NET variant) (All versions < 5.5.1), SCALANCE X202-2P IRT PRO (All versions < 5.5.1), SCALANCE X204 IRT (All versions < 5.5.1), SCALANCE X204 IRT PRO (All versions < 5.5.1), SCALANCE X204-2 (incl. SIPLUS NET variant) (All versions < V5.2.5), SCALANCE X204-2FM (All versions < V5.2.5), SCALANCE X204-2LD (incl. SIPLUS NET variant) (All versions < V5.2.5), SCALANCE X204-2LD TS (All versions < V5.2.5), SCALANCE X204-2TS (All versions < V5.2.5), SCALANCE X206-1 (All versions < V5.2.5), SCALANCE X206-1LD (All versions < V5.2.5), SCALANCE X208 (incl. SIPLUS NET variant) (All versions < V5.2.5), SCALANCE X208PRO (All versions < V5.2.5), SCALANCE X212-2 (incl. SIPLUS NET variant) (All versions < V5.2.5), SCALANCE X212-2LD (All versions < V5.2.5), SCALANCE X216 (All versions < V5.2.5), SCALANCE X224 (All versions < V5.2.5), SCALANCE XF201-3P IRT (All versions < 5.5.1), SCALANCE XF202-2P IRT (All versions < 5.5.1), SCALANCE XF204 (All versions < V5.2.5), SCALANCE XF204 IRT (All versions < 5.5.1), SCALANCE XF204-2 (incl. SIPLUS NET variant) (All versions < V5.2.5), SCALANCE XF204-2BA IRT (All versions < 5.5.1), SCALANCE XF206-1 (All versions < V5.2.5), SCALANCE XF208 (All versions < V5.2.5). Incorrect processing of POST requests in the web server may write out of bounds in stack. An attacker might leverage this to denial-of-service of the device or remote code execution.
CVE-2020-26997 1 Siemens 2 Solid Edge Se2020, Solid Edge Se2021 2024-02-28 6.8 MEDIUM 7.8 HIGH
A vulnerability has been identified in Solid Edge SE2020 (All versions < SE2020MP13), Solid Edge SE2020 (All versions < SE2020MP14), Solid Edge SE2021 (All Versions < SE2021MP4). Affected applications lack proper validation of user-supplied data when parsing PAR files. This could lead to pointer dereferences of a value obtained from untrusted source. An attacker could leverage this vulnerability to execute code in the context of the current process. (ZDI-CAN-11919)
CVE-2021-29998 2 Siemens, Windriver 71 Ruggedcom Win Subscriber Station, Ruggedcom Win Subscriber Station Firmware, Scalance X200-4 P Irt and 68 more 2024-02-28 7.5 HIGH 9.8 CRITICAL
An issue was discovered in Wind River VxWorks before 6.5. There is a possible heap overflow in dhcp client.
CVE-2021-37713 4 Microsoft, Npmjs, Oracle and 1 more 4 Windows, Tar, Graalvm and 1 more 2024-02-28 4.4 MEDIUM 8.6 HIGH
The npm package "tar" (aka node-tar) before versions 4.4.18, 5.0.10, and 6.1.9 has an arbitrary file creation/overwrite and arbitrary code execution vulnerability. node-tar aims to guarantee that any file whose location would be outside of the extraction target directory is not extracted. This is, in part, accomplished by sanitizing absolute paths of entries within the archive, skipping archive entries that contain `..` path portions, and resolving the sanitized paths against the extraction target directory. This logic was insufficient on Windows systems when extracting tar files that contained a path that was not an absolute path, but specified a drive letter different from the extraction target, such as `C:some\path`. If the drive letter does not match the extraction target, for example `D:\extraction\dir`, then the result of `path.resolve(extractionDirectory, entryPath)` would resolve against the current working directory on the `C:` drive, rather than the extraction target directory. Additionally, a `..` portion of the path could occur immediately after the drive letter, such as `C:../foo`, and was not properly sanitized by the logic that checked for `..` within the normalized and split portions of the path. This only affects users of `node-tar` on Windows systems. These issues were addressed in releases 4.4.18, 5.0.10 and 6.1.9. The v3 branch of node-tar has been deprecated and did not receive patches for these issues. If you are still using a v3 release we recommend you update to a more recent version of node-tar. There is no reasonable way to work around this issue without performing the same path normalization procedures that node-tar now does. Users are encouraged to upgrade to the latest patched versions of node-tar, rather than attempt to sanitize paths themselves.
CVE-2021-34320 1 Siemens 2 Jt2go, Teamcenter Visualization 2024-02-28 4.3 MEDIUM 5.5 MEDIUM
A vulnerability has been identified in JT2Go (All versions < V13.2), Teamcenter Visualization (All versions < V13.2). The Jt981.dll library in affected applications lacks proper validation of user-supplied data when parsing JT files. This could result in an out of bounds read past the end of an allocated buffer. An attacker could leverage this vulnerability to leak information in the context of the current process. (ZDI-CAN-13406)
CVE-2020-27738 1 Siemens 6 Nucleus Net, Nucleus Readystart V3, Nucleus Readystart V4 and 3 more 2024-02-28 5.8 MEDIUM 7.4 HIGH
A vulnerability has been identified in APOGEE PXC Compact (BACnet) (All versions < V3.5.5), APOGEE PXC Compact (P2 Ethernet) (All versions < V2.8.20), APOGEE PXC Modular (BACnet) (All versions < V3.5.5), APOGEE PXC Modular (P2 Ethernet) (All versions < V2.8.20), Nucleus NET (All versions), Nucleus ReadyStart V3 (All versions < V2017.02.3), Nucleus ReadyStart V4 (All versions < V4.1.0), Nucleus Source Code (Versions including affected DNS modules), SIMOTICS CONNECT 400 (All versions < V0.5.0.0), TALON TC Compact (BACnet) (All versions < V3.5.5), TALON TC Modular (BACnet) (All versions < V3.5.5). The DNS domain name record decompression functionality does not properly validate the pointer offset values. The parsing of malformed responses could result in a read access past the end of an allocated structure. An attacker with a privileged position in the network could leverage this vulnerability to cause a denial-of-service condition.