Vulnerabilities (CVE)

Filtered by vendor Deltaww Subscribe
Total 224 CVE
CVE Vendors Products Updated CVSS v2 CVSS v3
CVE-2022-41701 1 Deltaww 1 Diaenergie 2024-02-28 N/A 5.4 MEDIUM
The affected product DIAEnergie (versions prior to v1.9.01.002) is vulnerable to a stored cross-site scripting vulnerability through the PutShift API.
CVE-2022-1405 1 Deltaww 1 Cncsoft 2024-02-28 N/A 7.8 HIGH
CNCSoft: All versions prior to 1.01.32 does not properly sanitize input while processing a specific project file, allowing a possible stack-based buffer overflow condition.
CVE-2022-40965 1 Deltaww 1 Diaenergie 2024-02-28 N/A 5.4 MEDIUM
The affected product DIAEnergie (versions prior to v1.9.01.002) is vulnerable to a stored cross-site scripting vulnerability through the PostEnergyType API.
CVE-2022-41651 1 Deltaww 1 Diaenergie 2024-02-28 N/A 5.4 MEDIUM
The affected product DIAEnergie (versions prior to v1.9.01.002) is vulnerable to a stored cross-site scripting vulnerability through the SetPF API.
CVE-2022-41772 1 Deltaww 1 Infrasuite Device Master 2024-02-28 N/A 9.8 CRITICAL
Delta Electronics InfraSuite Device Master Versions 00.00.01a and prior mishandle .ZIP archives containing characters used in path traversal. This path traversal could result in remote code execution.
CVE-2022-43775 1 Deltaww 1 Diaenergie 2024-02-28 N/A 9.8 CRITICAL
The HICT_Loop class in Delta Electronics DIAEnergy v1.9 contains a SQL Injection flaw that could allow an attacker to gain code execution on a remote system.
CVE-2022-41133 1 Deltaww 1 Diaenergie 2024-02-28 N/A 8.8 HIGH
The affected product DIAEnergie (versions prior to v1.9.01.002) is vulnerable to a SQL injection that exists in GetDIAE_line_message_settingsListParameters. A low-privileged authenticated attacker could exploit this issue to inject arbitrary SQL queries.
CVE-2022-43774 1 Deltaww 1 Diaenergie 2024-02-28 N/A 9.8 CRITICAL
The HandlerPageP_KID class in Delta Electronics DIAEnergy v1.9 contains a SQL Injection flaw that could allow an attacker to gain code execution on a remote system.
CVE-2022-38142 1 Deltaww 1 Infrasuite Device Master 2024-02-28 N/A 9.8 CRITICAL
Delta Electronics InfraSuite Device Master versions 00.00.01a and prior deserialize user-supplied data provided through the Device-Gateway service port without proper verification. An attacker could provide malicious serialized objects to execute arbitrary code upon deserialization.
CVE-2022-40967 1 Deltaww 1 Diaenergie 2024-02-28 N/A 8.8 HIGH
The affected product DIAEnergie (versions prior to v1.9.01.002) is vulnerable to a SQL injection that exists in CheckIoTHubNameExisted. A low-privileged authenticated attacker could exploit this issue to inject arbitrary SQL queries.
CVE-2022-41644 1 Deltaww 1 Infrasuite Device Master 2024-02-28 N/A 8.8 HIGH
Delta Electronics InfraSuite Device Master versions 00.00.01a and prior lacks authentication for a function that changes group privileges. An attacker could use this to create a denial-of-service state or escalate their own privileges.
CVE-2022-41629 1 Deltaww 1 Infrasuite Device Master 2024-02-28 N/A 9.1 CRITICAL
Delta Electronics InfraSuite Device Master versions 00.00.01a and prior allow unauthenticated users to access the aprunning endpoint, which could allow an attacker to retrieve any file from the “RunningConfigs” directory. The attacker could then view and modify configuration files such as UserListInfo.xml, which would allow them to see existing administrative passwords.
CVE-2022-1404 1 Deltaww 1 Cncsoft 2024-02-28 N/A 7.1 HIGH
Delta Electronics CNCSoft (All versions prior to 1.01.32) does not properly sanitize input while processing a specific project file, allowing a possible out-of-bounds read condition.
CVE-2022-41555 1 Deltaww 1 Diaenergie 2024-02-28 N/A 5.4 MEDIUM
The affected product DIAEnergie (versions prior to v1.9.01.002) is vulnerable to a stored cross-site scripting vulnerability through the PutLineMessageSetting API.
CVE-2022-41773 1 Deltaww 1 Diaenergie 2024-02-28 N/A 8.8 HIGH
The affected product DIAEnergie (versions prior to v1.9.01.002) is vulnerable to a SQL injection that exists in CheckDIACloud. A low-privileged authenticated attacker could exploit this issue to inject arbitrary SQL queries.
CVE-2022-41702 1 Deltaww 1 Diaenergie 2024-02-28 N/A 5.4 MEDIUM
The affected product DIAEnergie (versions prior to v1.9.01.002) is vulnerable to a stored cross-site scripting vulnerability through the InsertReg API.
CVE-2022-3214 1 Deltaww 1 Diaenergie 2024-02-28 N/A 9.8 CRITICAL
Delta Industrial Automation's DIAEnergy, an industrial energy management system, is vulnerable to CWE-798, Use of Hard-coded Credentials. Versions prior to  1.9.03.009 have this vulnerability. Executable files could be uploaded to certain directories using hard-coded bearer authorization, allowing remote code execution.
CVE-2022-2759 1 Deltaww 1 Delta Robot Automation Studio 2024-02-28 N/A 8.6 HIGH
Delta Electronics Delta Robot Automation Studio (DRAS) versions prior to 1.13.20 are affected by improper restrictions where the software processes an XML document that can contain XML entities with URIs that resolve to documents outside of the intended sphere of control, causing the product to embed incorrect documents into its output. This may allow an attacker to view sensitive documents and information on the affected host.
CVE-2022-27175 1 Deltaww 1 Diaenergie 2024-02-28 10.0 HIGH 9.8 CRITICAL
Delta Electronics DIAEnergie (All versions prior to 1.8.02.004) has a blind SQL injection vulnerability that exists in GetCalcTagList. This allows an attacker to inject arbitrary SQL queries, retrieve and modify database contents, and execute system commands.
CVE-2022-26065 1 Deltaww 1 Diaenergie 2024-02-28 10.0 HIGH 9.8 CRITICAL
Delta Electronics DIAEnergie (All versions prior to 1.8.02.004) has a blind SQL injection vulnerability exists in GetLatestDemandNode. This allows an attacker to inject arbitrary SQL queries, retrieve and modify database contents, and execute system commands.