Filtered by vendor Deltaww
Subscribe
Total
224 CVE
CVE | Vendors | Products | Updated | CVSS v2 | CVSS v3 |
---|---|---|---|---|---|
CVE-2023-24014 | 1 Deltaww | 1 Cncsoft-b | 2024-02-28 | N/A | 7.8 HIGH |
Delta Electronics' CNCSoft-B DOPSoft versions 1.0.0.4 and prior are vulnerable to heap-based buffer overflow, which could allow an attacker to execute arbitrary code. | |||||
CVE-2023-1144 | 1 Deltaww | 1 Infrasuite Device Master | 2024-02-28 | N/A | 8.8 HIGH |
Delta Electronics InfraSuite Device Master versions prior to 1.0.5 contains an improper access control vulnerability in which an attacker can use the Device-Gateway service and bypass authorization, which could result in privilege escalation. | |||||
CVE-2023-0432 | 1 Deltaww | 2 Dx-2100l1-cn, Dx-2100l1-cn Firmware | 2024-02-28 | N/A | 9.0 CRITICAL |
The web configuration service of the affected device contains an authenticated command injection vulnerability. It can be used to execute system commands on the operating system (OS) from the device in the context of the user "root." If the attacker has credentials for the web service, then the device could be fully compromised. | |||||
CVE-2023-30765 | 1 Deltaww | 1 Infrasuite Device Master | 2024-02-28 | N/A | 9.8 CRITICAL |
?Delta Electronics InfraSuite Device Master versions prior to 1.0.7 contain improper access controls that could allow an attacker to alter privilege management configurations, resulting in privilege escalation. | |||||
CVE-2023-1141 | 1 Deltaww | 1 Infrasuite Device Master | 2024-02-28 | N/A | 8.8 HIGH |
Delta Electronics InfraSuite Device Master versions prior to 1.0.5 contain a command injection vulnerability that could allow an attacker to inject arbitrary commands, which could result in remote code execution. | |||||
CVE-2023-1135 | 1 Deltaww | 1 Infrasuite Device Master | 2024-02-28 | N/A | 7.8 HIGH |
In Delta Electronics InfraSuite Device Master versions prior to 1.0.5, an attacker could set incorrect directory permissions, which could result in local privilege escalation. | |||||
CVE-2023-1142 | 1 Deltaww | 1 Infrasuite Device Master | 2024-02-28 | N/A | 9.8 CRITICAL |
In Delta Electronics InfraSuite Device Master versions prior to 1.0.5, an attacker could use URL decoding to retrieve system files, credentials, and bypass authentication resulting in privilege escalation. | |||||
CVE-2023-1134 | 1 Deltaww | 1 Infrasuite Device Master | 2024-02-28 | N/A | 8.8 HIGH |
Delta Electronics InfraSuite Device Master versions prior to 1.0.5 are affected by a path traversal vulnerability, which could allow an attacker to read local files, disclose plaintext credentials, and escalate privileges. | |||||
CVE-2023-25177 | 1 Deltaww | 1 Cncsoft-b | 2024-02-28 | N/A | 7.8 HIGH |
Delta Electronics' CNCSoft-B DOPSoft versions 1.0.0.4 and prior are vulnerable to stack-based buffer overflow, which could allow an attacker to execute arbitrary code. | |||||
CVE-2023-1136 | 1 Deltaww | 1 Infrasuite Device Master | 2024-02-28 | N/A | 7.5 HIGH |
In Delta Electronics InfraSuite Device Master versions prior to 1.0.5, an unauthenticated attacker could generate a valid token, which would lead to authentication bypass. | |||||
CVE-2023-1139 | 1 Deltaww | 1 Infrasuite Device Master | 2024-02-28 | N/A | 8.8 HIGH |
Delta Electronics InfraSuite Device Master versions prior to 1.0.5 are affected by a deserialization vulnerability targeting the Device-gateway service, which could allow deserialization of requests prior to authentication, resulting in remote code execution. | |||||
CVE-2023-1143 | 1 Deltaww | 1 Infrasuite Device Master | 2024-02-28 | N/A | 8.8 HIGH |
In Delta Electronics InfraSuite Device Master versions prior to 1.0.5, an attacker could use Lua scripts, which could allow an attacker to remotely execute arbitrary code. | |||||
CVE-2023-1140 | 1 Deltaww | 1 Infrasuite Device Master | 2024-02-28 | N/A | 9.8 CRITICAL |
Delta Electronics InfraSuite Device Master versions prior to 1.0.5 contain a vulnerability that could allow an attacker to achieve unauthenticated remote code execution in the context of an administrator. | |||||
CVE-2023-34316 | 1 Deltaww | 1 Infrasuite Device Master | 2024-02-28 | N/A | 7.5 HIGH |
?An attacker could bypass the latest Delta Electronics InfraSuite Device Master (versions prior to 1.0.7) patch, which could allow an attacker to retrieve file contents. | |||||
CVE-2023-1138 | 1 Deltaww | 1 Infrasuite Device Master | 2024-02-28 | N/A | 7.5 HIGH |
Delta Electronics InfraSuite Device Master versions prior to 1.0.5 contain an improper access control vulnerability, which could allow an attacker to retrieve Gateway configuration files to obtain plaintext credentials. | |||||
CVE-2023-1133 | 1 Deltaww | 1 Infrasuite Device Master | 2024-02-28 | N/A | 9.8 CRITICAL |
Delta Electronics InfraSuite Device Master versions prior to 1.0.5 contain a vulnerability in which the Device-status service listens on port 10100/ UDP by default. The service accepts the unverified UDP packets and deserializes the content, which could allow an unauthenticated attacker to remotely execute arbitrary code. | |||||
CVE-2023-1145 | 1 Deltaww | 1 Infrasuite Device Master | 2024-02-28 | N/A | 7.8 HIGH |
Delta Electronics InfraSuite Device Master versions prior to 1.0.5 are affected by a deserialization vulnerability targeting the Device-DataCollect service, which could allow deserialization of requests prior to authentication, resulting in remote code execution. | |||||
CVE-2023-1137 | 1 Deltaww | 1 Infrasuite Device Master | 2024-02-28 | N/A | 8.8 HIGH |
Delta Electronics InfraSuite Device Master versions prior to 1.0.5 contain a vulnerability in which a low-level user could extract files and plaintext credentials of administrator users, resulting in privilege escalation. | |||||
CVE-2023-34347 | 1 Deltaww | 1 Infrasuite Device Master | 2024-02-28 | N/A | 9.8 CRITICAL |
?Delta Electronics InfraSuite Device Master versions prior to 1.0.7 contains classes that cannot be deserialized, which could allow an attack to remotely execute arbitrary code. | |||||
CVE-2023-0822 | 1 Deltaww | 1 Diaenergie | 2024-02-28 | N/A | 8.8 HIGH |
The affected product DIAEnergie (versions prior to v1.9.03.001) contains improper authorization, which could allow an unauthorized user to bypass authorization and access privileged functionality. |