Filtered by vendor Deltaww
Subscribe
Total
224 CVE
CVE | Vendors | Products | Updated | CVSS v2 | CVSS v3 |
---|---|---|---|---|---|
CVE-2022-4634 | 1 Deltaww | 2 Cncsoft, Screeneditor | 2024-02-28 | N/A | 7.8 HIGH |
All versions prior to Delta Electronic’s CNCSoft version 1.01.34 (running ScreenEditor versions 1.01.5 and prior) are vulnerable to a stack-based buffer overflow, which could allow an attacker to remotely execute arbitrary code. | |||||
CVE-2022-43457 | 1 Deltaww | 1 Diaenergie | 2024-02-28 | N/A | 8.8 HIGH |
SQL Injection in HandlerPage_KID.ashx in Delta Electronics DIAEnergie versions prior to v1.9.02.001 allows an attacker to inject SQL queries via Network | |||||
CVE-2022-43447 | 1 Deltaww | 1 Diaenergie | 2024-02-28 | N/A | 8.8 HIGH |
SQL Injection in AM_EBillAnalysis.aspx in Delta Electronics DIAEnergie versions prior to v1.9.02.001 allows an attacker to inject SQL queries via Network | |||||
CVE-2022-4616 | 1 Deltaww | 2 Dx-3021l9, Dx-3021l9 Firmware | 2024-02-28 | N/A | 9.1 CRITICAL |
The webserver in Delta DX-3021 versions prior to 1.24 is vulnerable to command injection through the network diagnosis page. This vulnerability could allow a remote unauthenticated user to add files, delete files, and change file permissions. | |||||
CVE-2023-0251 | 1 Deltaww | 1 Diascreen | 2024-02-28 | N/A | 7.8 HIGH |
Delta Electronics DIAScreen versions 1.2.1.23 and prior are vulnerable to a buffer overflow through improper restrictions of operations within memory, which could allow an attacker to remotely execute arbitrary code. | |||||
CVE-2022-2660 | 1 Deltaww | 1 Dialink | 2024-02-28 | N/A | 7.5 HIGH |
Delta Industrial Automation DIALink versions 1.4.0.0 and prior are vulnerable to the use of a hard-coded cryptographic key which could allow an attacker to decrypt sensitive data and compromise the machine. | |||||
CVE-2023-0249 | 1 Deltaww | 1 Diascreen | 2024-02-28 | N/A | 7.8 HIGH |
Delta Electronics DIAScreen versions 1.2.1.23 and prior are vulnerable to out-of-bounds write, which may allow an attacker to remotely execute arbitrary code. | |||||
CVE-2022-43506 | 1 Deltaww | 1 Diaenergie | 2024-02-28 | N/A | 8.8 HIGH |
SQL Injection in HandlerTag_KID.ashx in Delta Electronics DIAEnergie versions prior to v1.9.02.001 allows an attacker to inject SQL queries via Network | |||||
CVE-2022-42140 | 1 Deltaww | 2 Dx-2100-l1-cn, Dx-2100-l1-cn Firmware | 2024-02-28 | N/A | 7.2 HIGH |
Delta Electronics DX-2100-L1-CN 2.42 is vulnerable to Command Injection via lform/net_diagnose. | |||||
CVE-2022-43452 | 1 Deltaww | 1 Diaenergie | 2024-02-28 | N/A | 8.8 HIGH |
SQL Injection in FtyInfoSetting.aspx in Delta Electronics DIAEnergie versions prior to v1.9.02.001 allows an attacker to inject SQL queries via Network | |||||
CVE-2022-42141 | 1 Deltaww | 2 Dx-2100-l1-cn, Dx-2100-l1-cn Firmware | 2024-02-28 | N/A | 5.4 MEDIUM |
Delta Electronics DX-2100-L1-CN 2.42 is vulnerable to Cross Site Scripting (XSS) via lform/urlfilter. | |||||
CVE-2023-0124 | 1 Deltaww | 1 Dopsoft | 2024-02-28 | N/A | 7.8 HIGH |
Delta Electronics DOPSoft versions 4.00.16.22 and prior are vulnerable to an out-of-bounds write, which could allow an attacker to remotely execute arbitrary code when a malformed file is introduced to the software. | |||||
CVE-2022-41778 | 1 Deltaww | 1 Infrasuite Device Master | 2024-02-28 | N/A | 8.8 HIGH |
Delta Electronics InfraSuite Device Master versions 00.00.01a and prior deserialize user-supplied data provided through the Device-DataCollect service port without proper verification. An attacker could provide malicious serialized objects to execute arbitrary code upon deserialization. | |||||
CVE-2023-0444 | 1 Deltaww | 1 Infrasuite Device Master | 2024-02-28 | N/A | 8.8 HIGH |
A privilege escalation vulnerability exists in Delta Electronics InfraSuite Device Master 00.00.02a. A default user 'User', which is in the 'Read Only User' group, can view the password of another default user 'Administrator', which is in the 'Administrator' group. This allows any lower privileged user to log in as an administrator. | |||||
CVE-2023-0250 | 1 Deltaww | 1 Diascreen | 2024-02-28 | N/A | 7.8 HIGH |
Delta Electronics DIAScreen versions 1.2.1.23 and prior are vulnerable to a stack-based buffer overflow, which could allow an attacker to remotely execute arbitrary code. | |||||
CVE-2022-40202 | 1 Deltaww | 1 Infrasuite Device Master | 2024-02-28 | N/A | 9.8 CRITICAL |
The database backup function in Delta Electronics InfraSuite Device Master Versions 00.00.01a and prior lacks proper authentication. An attacker could provide malicious serialized objects which, when deserialized, could activate an opcode for a backup scheduling function without authentication. This function allows the user to designate all function arguments and the file to be executed. This could allow the attacker to start any new process and achieve remote code execution. | |||||
CVE-2022-41776 | 1 Deltaww | 1 Infrasuite Device Master | 2024-02-28 | N/A | 7.5 HIGH |
Delta Electronics InfraSuite Device Master versions 00.00.01a and prior allow unauthenticated users to trigger the WriteConfiguration method, which could allow an attacker to provide new values for user configuration files such as UserListInfo.xml. This could lead to the changing of administrative passwords. | |||||
CVE-2022-41688 | 1 Deltaww | 1 Infrasuite Device Master | 2024-02-28 | N/A | 7.5 HIGH |
Delta Electronics InfraSuite Device Master versions 00.00.01a and prior lack proper authentication for functions that create and modify user groups. An attacker could provide malicious serialized objects that could run these functions without authentication to create a new user and add them to the administrator group. | |||||
CVE-2022-41779 | 1 Deltaww | 1 Infrasuite Device Master | 2024-02-28 | N/A | 9.8 CRITICAL |
Delta Electronics InfraSuite Device Master versions 00.00.01a and prior deserialize network packets without proper verification. If the device connects to an attacker-controlled server, the attacker could send maliciously crafted packets that would be deserialized and executed, leading to remote code execution. | |||||
CVE-2022-41657 | 1 Deltaww | 1 Infrasuite Device Master | 2024-02-28 | N/A | 9.8 CRITICAL |
Delta Electronics InfraSuite Device Master Versions 00.00.01a and prior allow attacker provided data already serialized into memory to be used in file operation application programmable interfaces (APIs). This could create arbitrary files, which could be used in API operations and could ultimately result in remote code execution. |