Filtered by vendor Schneider-electric
Subscribe
Total
752 CVE
CVE | Vendors | Products | Updated | CVSS v2 | CVSS v3 |
---|---|---|---|---|---|
CVE-2018-7829 | 1 Schneider-electric | 118 D6220, D6220 Firmware, D6220l and 115 more | 2024-02-28 | 9.0 HIGH | 8.8 HIGH |
An Improper Neutralization of Special Elements in Query vulnerability exists in the 1st Gen. Pelco Sarix Enhanced Camera and Spectra Enhanced PTZ Camera which allows an attacker to execute arbitrary system commands. | |||||
CVE-2018-7853 | 1 Schneider-electric | 8 Modicon M340, Modicon M340 Firmware, Modicon M580 and 5 more | 2024-02-28 | 5.0 MEDIUM | 7.5 HIGH |
A CWE-248: Uncaught Exception vulnerability exists in all versions of the Modicon M580, Modicon M340, Modicon Quantum, and Modicon Premium which could cause denial of service when reading invalid physical memory blocks in the controller over Modbus | |||||
CVE-2019-6824 | 1 Schneider-electric | 1 Proclima | 2024-02-28 | 10.0 HIGH | 9.8 CRITICAL |
A CWE-119: Buffer Errors vulnerability exists in ProClima (all versions prior to version 8.0.0) which allows an unauthenticated, remote attacker to execute arbitrary code on the targeted system in all versions of ProClima prior to version 8.0.0. | |||||
CVE-2019-6838 | 1 Schneider-electric | 8 Meg6260-0410, Meg6260-0410 Firmware, Meg6260-0415 and 5 more | 2024-02-28 | 5.5 MEDIUM | 6.5 MEDIUM |
A CWE-863: Incorrect Authorization vulnerability exists in U.motion Server (MEG6501-0001 - U.motion KNX server, MEG6501-0002 - U.motion KNX Server Plus, MEG6260-0410 - U.motion KNX Server Plus, Touch 10, MEG6260-0415 - U.motion KNX Server Plus, Touch 15), which could allow a user with low privileges to delete a critical file. | |||||
CVE-2019-6830 | 1 Schneider-electric | 2 Modicon M580, Modicon M580 Firmware | 2024-02-28 | 7.1 HIGH | 5.9 MEDIUM |
A CWE-248: Uncaught Exception vulnerability exists IN Modicon M580 all versions prior to V2.80, which could cause a possible denial of service when sending an appropriately timed HTTP request to the controller. | |||||
CVE-2019-6823 | 1 Schneider-electric | 1 Proclima | 2024-02-28 | 10.0 HIGH | 9.8 CRITICAL |
A CWE-94: Code Injection vulnerability exists in ProClima (all versions prior to version 8.0.0) which could allow an unauthenticated, remote attacker to execute arbitrary code on the targeted system in all versions of ProClima prior to version 8.0.0. | |||||
CVE-2018-7838 | 1 Schneider-electric | 36 Bmeh582040, Bmeh582040 Firmware, Bmeh582040c and 33 more | 2024-02-28 | 7.8 HIGH | 7.5 HIGH |
A CWE-119 Buffer Errors vulnerability exists in Modicon M580 CPU - BMEP582040, all versions before V2.90, and Modicon Ethernet Module BMENOC0301, all versions before V2.16, which could cause denial of service on the FTP service of the controller or the Ethernet BMENOC module when it receives a FTP CWD command with a data length greater than 1020 bytes. A power cycle is then needed to reactivate the FTP service. | |||||
CVE-2018-7843 | 1 Schneider-electric | 8 Modicon M340, Modicon M340 Firmware, Modicon M580 and 5 more | 2024-02-28 | 5.0 MEDIUM | 7.5 HIGH |
A CWE-248: Uncaught Exception vulnerability exists in all versions of the Modicon M580, Modicon M340, Modicon Quantum, and Modicon Premium which could cause denial of service when reading memory blocks with an invalid data size or with an invalid data offset in the controller over Modbus. | |||||
CVE-2019-6828 | 1 Schneider-electric | 8 Modicon M340, Modicon M340 Firmware, Modicon M580 and 5 more | 2024-02-28 | 7.8 HIGH | 7.5 HIGH |
A CWE-248: Uncaught Exception vulnerability exists Modicon M580 (firmware version prior to V2.90), Modicon M340 (firmware version prior to V3.10), Modicon Premium (all versions), and Modicon Quantum (all versions), which could cause a possible denial of service when reading specific coils and registers in the controller over Modbus. | |||||
CVE-2018-7821 | 1 Schneider-electric | 3 Modicon M221, Modicon M221 Firmware, Somachine Basic | 2024-02-28 | 5.0 MEDIUM | 7.5 HIGH |
An Environment (CWE-2) vulnerability exists in SoMachine Basic, all versions, and Modicon M221(all references, all versions prior to firmware V1.10.0.0) which could cause cycle time impact when flooding the M221 ethernet interface while the Ethernet/IP adapter is activated. | |||||
CVE-2019-6808 | 1 Schneider-electric | 8 Modicon M340, Modicon M340 Firmware, Modicon M580 and 5 more | 2024-02-28 | 7.5 HIGH | 9.8 CRITICAL |
A CWE-284: Improper Access Control vulnerability exists in all versions of the Modicon M580, Modicon M340, Modicon Quantum, and Modicon Premium which could cause a remote code execution by overwriting configuration settings of the controller over Modbus. | |||||
CVE-2019-10953 | 5 Abb, Phoenixcontact, Schneider-electric and 2 more | 20 Pm554-tp-eth, Pm554-tp-eth Firmware, Ilc 151 Eth and 17 more | 2024-02-28 | 5.0 MEDIUM | 7.5 HIGH |
ABB, Phoenix Contact, Schneider Electric, Siemens, WAGO - Programmable Logic Controllers, multiple versions. Researchers have found some controllers are susceptible to a denial-of-service attack due to a flood of network packets. | |||||
CVE-2018-7816 | 1 Schneider-electric | 118 D6220, D6220 Firmware, D6220l and 115 more | 2024-02-28 | 5.5 MEDIUM | 6.5 MEDIUM |
A Permissions, Privileges, and Access Control vulnerability exists in the web-based GUI of the 1st Gen Pelco Sarix Enhanced Camera that could allow a remote attacker to delete an arbitrary file. | |||||
CVE-2019-6837 | 1 Schneider-electric | 8 Meg6260-0410, Meg6260-0410 Firmware, Meg6260-0415 and 5 more | 2024-02-28 | 6.4 MEDIUM | 9.1 CRITICAL |
A Server-Side Request Forgery (SSRF): CWE-918 vulnerability exists in U.motion Server (MEG6501-0001 - U.motion KNX server, MEG6501-0002 - U.motion KNX Server Plus, MEG6260-0410 - U.motion KNX Server Plus, Touch 10, MEG6260-0415 - U.motion KNX Server Plus, Touch 15), which could cause server configuration data to be exposed when an attacker modifies a URL. | |||||
CVE-2019-6822 | 1 Schneider-electric | 1 Zelio Soft 2 | 2024-02-28 | 6.8 MEDIUM | 7.8 HIGH |
A Use After Free: CWE-416 vulnerability exists in Zelio Soft 2, V5.2 and earlier, which could cause remote code execution when opening a specially crafted Zelio Soft 2 project file. | |||||
CVE-2019-6807 | 1 Schneider-electric | 8 Modicon M340, Modicon M340 Firmware, Modicon M580 and 5 more | 2024-02-28 | 5.0 MEDIUM | 7.5 HIGH |
A CWE-248: Uncaught Exception vulnerability exists in all versions of the Modicon M580, Modicon M340, Modicon Quantum, and Modicon Premium which could cause a possible denial of service when writing sensitive application variables to the controller over Modbus. | |||||
CVE-2019-6835 | 1 Schneider-electric | 8 Meg6260-0410, Meg6260-0410 Firmware, Meg6260-0415 and 5 more | 2024-02-28 | 3.5 LOW | 5.4 MEDIUM |
A Cross-Site Scripting (XSS) CWE-79 vulnerability exists in U.motion Server (MEG6501-0001 - U.motion KNX server, MEG6501-0002 - U.motion KNX Server Plus, MEG6260-0410 - U.motion KNX Server Plus, Touch 10, MEG6260-0415 - U.motion KNX Server Plus, Touch 15), which could allow an attacker to inject client-side script when a user visits a web page. | |||||
CVE-2018-7849 | 1 Schneider-electric | 8 Modicon M340, Modicon M340 Firmware, Modicon M580 and 5 more | 2024-02-28 | 5.0 MEDIUM | 7.5 HIGH |
A CWE-248: Uncaught Exception vulnerability exists in all versions of the Modicon M580, Modicon M340, Modicon Quantum and Modicon Premium which could cause a possible Denial of Service due to improper data integrity check when sending files the controller over Modbus. | |||||
CVE-2018-7788 | 1 Schneider-electric | 2 Modicon Quantum, Modicon Quantum Firmware | 2024-02-28 | 4.0 MEDIUM | 6.5 MEDIUM |
A CWE-255 Credentials Management vulnerability exists in Modicon Quantum with firmware versions prior to V2.40. which could cause a Denial Of Service when using a Telnet connection. | |||||
CVE-2018-7855 | 1 Schneider-electric | 8 Modicon M340, Modicon M340 Firmware, Modicon M580 and 5 more | 2024-02-28 | 5.0 MEDIUM | 7.5 HIGH |
A CWE-248 Uncaught Exception vulnerability exists in all versions of the Modicon M580, Modicon M340, Modicon Quantum, and Modicon Premium which could cause a Denial of Service when sending invalid breakpoint parameters to the controller over Modbus |