Filtered by vendor Schneider-electric
Subscribe
Total
755 CVE
CVE | Vendors | Products | Updated | CVSS v2 | CVSS v3 |
---|---|---|---|---|---|
CVE-2020-7501 | 1 Schneider-electric | 1 Vijeo Designer | 2024-11-21 | 6.5 MEDIUM | 8.8 HIGH |
A CWE-798: Use of Hard-coded Credentials vulnerability exists in Vijeo Designer Basic (V1.1 HotFix 16 and prior) and Vijeo Designer (V6.2 SP9 and prior) which could cause unauthorized read and write when downloading and uploading project or firmware into Vijeo Designer Basic and Vijeo Designer. | |||||
CVE-2020-7500 | 1 Schneider-electric | 12 Mtn6260-0310, Mtn6260-0310 Firmware, Mtn6260-0315 and 9 more | 2024-11-21 | 7.5 HIGH | 9.8 CRITICAL |
A CWE-89:Improper Neutralization of Special Elements used in an SQL Command ('SQL Injection') vulnerability exists in U.motion Servers and Touch Panels (affected versions listed in the security notification) which could cause arbitrary code to be executed when a malicious command is entered. | |||||
CVE-2020-7499 | 1 Schneider-electric | 12 Mtn6260-0310, Mtn6260-0310 Firmware, Mtn6260-0315 and 9 more | 2024-11-21 | 4.0 MEDIUM | 6.5 MEDIUM |
A CWE-863: Incorrect Authorization vulnerability exists in U.motion Servers and Touch Panels (affected versions listed in the security notification) which could cause unauthorized access when a low privileged user makes unauthorized changes. | |||||
CVE-2020-7498 | 1 Schneider-electric | 2 Os Loader, Unity Loader | 2024-11-21 | 7.5 HIGH | 9.8 CRITICAL |
A CWE-798: Use of Hard-coded Credentials vulnerability exists in the Unity Loader and OS Loader Software (all versions). The fixed credentials are used to simplify file transfer. Today the use of fixed credentials is considered a vulnerability, which could cause unauthorized access to the file transfer service provided by the Modicon PLCs. This could result in various unintended results. | |||||
CVE-2020-7497 | 1 Schneider-electric | 1 Ecostruxure Operator Terminal Expert | 2024-11-21 | 7.5 HIGH | 9.8 CRITICAL |
A CWE-22: Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal') vulnerability exists in EcoStruxure Operator Terminal Expert 3.1 Service Pack 1 and prior (formerly known as Vijeo XD)which could cause arbitrary application execution when the computer starts. | |||||
CVE-2020-7495 | 1 Schneider-electric | 1 Ecostruxure Operator Terminal Expert | 2024-11-21 | 4.3 MEDIUM | 5.5 MEDIUM |
A CWE-22: Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal') vulnerability during zip file extraction exists in EcoStruxure Operator Terminal Expert 3.1 Service Pack 1 and prior (formerly known as Vijeo XD) which could cause unauthorized write access outside of expected path folder when opening the project file. | |||||
CVE-2020-7494 | 1 Schneider-electric | 1 Ecostruxure Operator Terminal Expert | 2024-11-21 | 6.8 MEDIUM | 7.8 HIGH |
A CWE-22: Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal') vulnerability exists in EcoStruxure Operator Terminal Expert 3.1 Service Pack 1 and prior (formerly known as Vijeo XD) which could cause malicious code execution when opening the project file. | |||||
CVE-2020-7493 | 1 Schneider-electric | 1 Ecostruxure Operator Terminal Expert | 2024-11-21 | 6.8 MEDIUM | 7.8 HIGH |
A CWE-89: Improper Neutralization of Special Elements used in an SQL Command ('SQL Injection') vulnerability exists in EcoStruxure Operator Terminal Expert 3.1 Service Pack 1 and prior (formerly known as Vijeo XD) which could cause malicious code execution when opening the project file. | |||||
CVE-2020-7492 | 1 Schneider-electric | 1 Gp-pro Ex Firmware | 2024-11-21 | 4.3 MEDIUM | 6.5 MEDIUM |
A CWE-521: Weak Password Requirements vulnerability exists in the GP-Pro EX V1.00 to V4.09.100 which could cause the discovery of the password when the user is entering the password because it is not masqueraded. | |||||
CVE-2020-7491 | 1 Schneider-electric | 14 Tricon Tcm 4351, Tricon Tcm 4351 Firmware, Tricon Tcm 4351a and 11 more | 2024-11-21 | 5.0 MEDIUM | 7.5 HIGH |
**VERSION NOT SUPPORTED WHEN ASSIGNED** A legacy debug port account in TCMs installed in Tricon system versions 10.2.0 through 10.5.3 is visible on the network and could allow inappropriate access. This vulnerability was remediated in TCM version 10.5.4. | |||||
CVE-2020-7490 | 1 Schneider-electric | 1 Vijeo Designer | 2024-11-21 | 6.9 MEDIUM | 7.8 HIGH |
A CWE-426: Untrusted Search Path vulnerability exists in Vijeo Designer Basic (V1.1 HotFix 15 and prior) and Vijeo Designer (V6.9 SP9 and prior), which could cause arbitrary code execution on the system running Vijeo Basic when a malicious DLL library is loaded by the Product. | |||||
CVE-2020-7489 | 1 Schneider-electric | 8 Ecostruxure Machine Expert, Modicon M100, Modicon M100 Firmware and 5 more | 2024-11-21 | 7.5 HIGH | 9.8 CRITICAL |
A CWE-74: Improper Neutralization of Special Elements in Output Used by a Downstream Component ('Injection') vulnerability exists on EcoStruxure Machine Expert – Basic or SoMachine Basic programming software (versions in security notification). The result of this vulnerability, DLL substitution, could allow the transference of malicious code to the controller. | |||||
CVE-2020-7488 | 1 Schneider-electric | 11 Ecostruxure Machine Expert, Modicon M218, Modicon M218 Firmware and 8 more | 2024-11-21 | 5.0 MEDIUM | 7.5 HIGH |
A CWE-319: Cleartext Transmission of Sensitive Information vulnerability exists which could leak sensitive information transmitted between the software and the Modicon M218, M241, M251, and M258 controllers. | |||||
CVE-2020-7487 | 1 Schneider-electric | 11 Ecostruxure Machine Expert, Modicon M218, Modicon M218 Firmware and 8 more | 2024-11-21 | 7.5 HIGH | 9.8 CRITICAL |
A CWE-345: Insufficient Verification of Data Authenticity vulnerability exists which could allow the attacker to execute malicious code on the Modicon M218, M241, M251, and M258 controllers. | |||||
CVE-2020-7486 | 1 Schneider-electric | 12 Tricon Tcm 4351, Tricon Tcm 4351 Firmware, Tricon Tcm 4351a and 9 more | 2024-11-21 | 5.0 MEDIUM | 7.5 HIGH |
**VERSION NOT SUPPORTED WHEN ASSIGNED** A vulnerability could cause TCM modules to reset when under high network load in TCM v10.4.x and in system v10.3.x. This vulnerability was discovered and remediated in version v10.5.x on August 13, 2009. TCMs from v10.5.x and on will no longer exhibit this behavior. | |||||
CVE-2020-7485 | 2 Microsoft, Schneider-electric | 4 Windows 7, Windows Nt, Windows Xp and 1 more | 2024-11-21 | 7.5 HIGH | 9.8 CRITICAL |
**VERSION NOT SUPPORTED WHEN ASSIGNED** A legacy support account in the TriStation software version v4.9.0 and earlier could cause improper access to the TriStation host machine. This was addressed in TriStation version v4.9.1 and v4.10.1 released on May 30, 2013.1 | |||||
CVE-2020-7484 | 2 Microsoft, Schneider-electric | 4 Windows 7, Windows Nt, Windows Xp and 1 more | 2024-11-21 | 4.3 MEDIUM | 7.5 HIGH |
**VERSION NOT SUPPORTED WHEN ASSIGNED** A vulnerability with the former 'password' feature could allow a denial of service attack if the user is not following documented guidelines pertaining to dedicated TriStation connection and key-switch protection. This vulnerability was discovered and remediated in versions v4.9.1 and v4.10.1 on May 30, 2013. This feature is not present in version v4.9.1 and v4.10.1 through current. Therefore, the vulnerability is not present in these versions. | |||||
CVE-2020-7483 | 2 Microsoft, Schneider-electric | 4 Windows 7, Windows Nt, Windows Xp and 1 more | 2024-11-21 | 5.0 MEDIUM | 7.5 HIGH |
**VERSION NOT SUPPORTED WHEN ASSIGNED** A vulnerability could cause certain data to be visible on the network when the 'password' feature is enabled. This vulnerability was discovered in and remediated in versions v4.9.1 and v4.10.1 on May 30, 2013. The 'password' feature is an additional optional check performed by TS1131 that it is connected to a specific controller. This data is sent as clear text and is visible on the network. This feature is not present in TriStation 1131 versions v4.9.1 and v4.10.1 through current. Therefore, the vulnerability is not present in these versions. | |||||
CVE-2020-7482 | 1 Schneider-electric | 22 Andover Continuum 5720, Andover Continuum 5720 Firmware, Andover Continuum 5740 and 19 more | 2024-11-21 | 4.3 MEDIUM | 6.1 MEDIUM |
A CWE-79:Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting') vulnerability exists Andover Continuum (All versions), which could cause a Reflective Cross-site Scripting (XSS attack) when using the products' web server. | |||||
CVE-2020-7481 | 1 Schneider-electric | 22 Andover Continuum 5720, Andover Continuum 5720 Firmware, Andover Continuum 5740 and 19 more | 2024-11-21 | 4.3 MEDIUM | 6.1 MEDIUM |
A CWE-79:Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting') vulnerability exists Andover Continuum (All versions), which could enable a successful Cross-site Scripting (XSS attack) when using the products' web server. |