Vulnerabilities (CVE)

Filtered by vendor Schneider-electric Subscribe
Total 755 CVE
CVE Vendors Products Updated CVSS v2 CVSS v3
CVE-2021-22747 1 Schneider-electric 4 Tcm 4351b, Tcm 4351b Firmware, Triconex Model 3009 Mp and 1 more 2024-11-21 2.1 LOW 3.9 LOW
Improper Check for Unusual or Exceptional Conditions vulnerability exists in Triconex Model 3009 MP installed on Tricon V11.3.x systems that could cause module reset when TCM receives malformed TriStation packets while the write-protect keyswitch is in the program position. This CVE ID is unique from CVE-2021-22742, CVE-2021-22744, CVE-2021-22745, and CVE-2021-22746.
CVE-2021-22746 1 Schneider-electric 4 Tcm 4351b, Tcm 4351b Firmware, Triconex Model 3009 Mp and 1 more 2024-11-21 2.1 LOW 3.9 LOW
Improper Check for Unusual or Exceptional Conditions vulnerability exists in Triconex Model 3009 MP installed on Tricon V11.3.x systems that could cause module reset when TCM receives malformed TriStation packets while the write-protect keyswitch is in the program position. This CVE ID is unique from CVE-2021-22742, CVE-2021-22744, CVE-2021-22745, and CVE-2021-22747.
CVE-2021-22745 1 Schneider-electric 4 Tcm 4351b, Tcm 4351b Firmware, Triconex Model 3009 Mp and 1 more 2024-11-21 2.1 LOW 3.9 LOW
Improper Check for Unusual or Exceptional Conditions vulnerability exists in Triconex Model 3009 MP installed on Tricon V11.3.x systems that could cause module reset when TCM receives malformed TriStation packets while the write-protect keyswitch is in the program position. This CVE ID is unique from CVE-2021-22742, CVE-2021-22744, CVE-2021-22746, and CVE-2021-22747.
CVE-2021-22744 1 Schneider-electric 4 Tcm 4351b, Tcm 4351b Firmware, Triconex Model 3009 Mp and 1 more 2024-11-21 2.1 LOW 3.9 LOW
Improper Check for Unusual or Exceptional Conditions vulnerability exists in Triconex Model 3009 MP installed on Tricon V11.3.x systems that could cause module reset when TCM receives malformed TriStation packets while the write-protect keyswitch is in the program position. This CVE ID is unique from CVE-2021-22742, CVE-2021-22745, CVE-2021-22746, and CVE-2021-22747.
CVE-2021-22743 1 Schneider-electric 4 Tcm 4351b, Tcm 4351b Firmware, Triconex Model 3009 Mp and 1 more 2024-11-21 2.1 LOW 3.9 LOW
Improper Check for Unusual or Exceptional Conditions vulnerability exists in Triconex TCM 4351B installed on Tricon V11.3.x systems that could cause module reset when TCM receives malformed TriStation packets while the write-protect keyswitch is in the program position.
CVE-2021-22742 1 Schneider-electric 4 Tcm 4351b, Tcm 4351b Firmware, Triconex Model 3009 Mp and 1 more 2024-11-21 2.1 LOW 3.9 LOW
Improper Check for Unusual or Exceptional Conditions vulnerability exists in Triconex Model 3009 MP installed on Tricon V11.3.x systems that could cause module reset when TCM receives malformed TriStation packets while the write-protect keyswitch is in the program position.
CVE-2021-22741 1 Schneider-electric 3 Clearscada, Ecostruxure Geo Scada Expert 2019, Ecostruxure Geo Scada Expert 2020 2024-11-21 4.6 MEDIUM 6.7 MEDIUM
Use of Password Hash with Insufficient Computational Effort vulnerability exists in ClearSCADA (all versions), EcoStruxure Geo SCADA Expert 2019 (all versions), and EcoStruxure Geo SCADA Expert 2020 (V83.7742.1 and prior), which could cause the revealing of account credentials when server database files are available. Exposure of these files to an attacker can make the system vulnerable to password decryption attacks. Note that “.sde” configuration export files do not contain user account password hashes.
CVE-2021-22740 1 Schneider-electric 4 Homelynk, Homelynk Firmware, Spacelynk and 1 more 2024-11-21 4.0 MEDIUM 6.5 MEDIUM
Information Exposure vulnerability exists in homeLYnk (Wiser For KNX) and spaceLYnk V2.60 and prior which could cause information to be exposed when an unauthorized file is uploaded.
CVE-2021-22739 1 Schneider-electric 4 Homelynk, Homelynk Firmware, Spacelynk and 1 more 2024-11-21 4.3 MEDIUM 5.9 MEDIUM
Information Exposure vulnerability exists in homeLYnk (Wiser For KNX) and spaceLYnk V2.60 and prior which could cause a device to be compromised when it is first configured.
CVE-2021-22738 1 Schneider-electric 4 Homelynk, Homelynk Firmware, Spacelynk and 1 more 2024-11-21 5.0 MEDIUM 9.8 CRITICAL
Use of a Broken or Risky Cryptographic Algorithm vulnerability exists in homeLYnk (Wiser For KNX) and spaceLYnk V2.60 and prior that could cause unauthorized access when credentials are discovered after a brute force attack.
CVE-2021-22737 1 Schneider-electric 4 Homelynk, Homelynk Firmware, Spacelynk and 1 more 2024-11-21 5.0 MEDIUM 9.8 CRITICAL
Insufficiently Protected Credentials vulnerability exists in homeLYnk (Wiser For KNX) and spaceLYnk V2.60 and prior that could cause unauthorized access of when credentials are discovered after a brute force attack.
CVE-2021-22736 1 Schneider-electric 4 Homelynk, Homelynk Firmware, Spacelynk and 1 more 2024-11-21 5.0 MEDIUM 7.5 HIGH
Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal') vulnerability exists in homeLYnk (Wiser For KNX) and spaceLYnk V2.60 and prior which could cause a denial of service when an unauthorized file is uploaded.
CVE-2021-22735 1 Schneider-electric 4 Homelynk, Homelynk Firmware, Spacelynk and 1 more 2024-11-21 6.5 MEDIUM 7.2 HIGH
Improper Verification of Cryptographic Signature vulnerability exists inhomeLYnk (Wiser For KNX) and spaceLYnk V2.60 and prior which could allow remote code execution when unauthorized code is copied to the device.
CVE-2021-22734 1 Schneider-electric 4 Homelynk, Homelynk Firmware, Spacelynk and 1 more 2024-11-21 6.5 MEDIUM 7.2 HIGH
Improper Verification of Cryptographic Signature vulnerability exists in homeLYnk (Wiser For KNX) and spaceLYnk V2.60 and prior which could cause remote code execution when an attacker loads unauthorized code.
CVE-2021-22733 1 Schneider-electric 4 Homelynk, Homelynk Firmware, Spacelynk and 1 more 2024-11-21 4.6 MEDIUM 7.8 HIGH
Improper Privilege Management vulnerability exists in homeLYnk (Wiser For KNX) and spaceLYnk V2.60 and prior which could cause shell access when unauthorized code is loaded into the system folder.
CVE-2021-22732 1 Schneider-electric 4 Homelynk, Homelynk Firmware, Spacelynk and 1 more 2024-11-21 4.6 MEDIUM 7.8 HIGH
Improper Privilege Management vulnerability exists in homeLYnk (Wiser For KNX) and spaceLYnk V2.60 and prior which could cause a code execution issue when an attacker loads unauthorized code on the web server.
CVE-2021-22731 1 Schneider-electric 32 Mcsesm043f23f0, Mcsesm043f23f0 Firmware, Mcsesm053f1cs0 and 29 more 2024-11-21 7.5 HIGH 9.8 CRITICAL
Weak Password Recovery Mechanism for Forgotten Password vulnerability exists on Modicon Managed Switch MCSESM* and MCSESP* V8.21 and prior which could cause an unauthorized password change through HTTP / HTTPS when basic user information is known by a remote attacker.
CVE-2021-22730 1 Schneider-electric 12 Evlink City Evc1s22p4, Evlink City Evc1s22p4 Firmware, Evlink City Evc1s7p4 and 9 more 2024-11-21 10.0 HIGH 9.8 CRITICAL
A CWE-798: Use of Hard-coded Credentials vulnerability exists in EVlink City (EVC1S22P4 / EVC1S7P4 all versions prior to R8 V3.4.0.1), EVlink Parking (EVW2 / EVF2 / EV.2 all versions prior to R8 V3.4.0.1), and EVlink Smart Wallbox (EVB1A all versions prior to R8 V3.4.0.1 ) that could an attacker to gain unauthorized administrative privileges when accessing to the charging station web server.
CVE-2021-22729 1 Schneider-electric 12 Evlink City Evc1s22p4, Evlink City Evc1s22p4 Firmware, Evlink City Evc1s7p4 and 9 more 2024-11-21 10.0 HIGH 9.8 CRITICAL
A CWE-259: Use of Hard-coded Password vulnerability exists in EVlink City (EVC1S22P4 / EVC1S7P4 all versions prior to R8 V3.4.0.1), EVlink Parking (EVW2 / EVF2 / EV.2 all versions prior to R8 V3.4.0.1), and EVlink Smart Wallbox (EVB1A all versions prior to R8 V3.4.0.1 ) that could allow an attacker to gain unauthorized administrative privileges when accessing to the charging station web server.
CVE-2021-22728 1 Schneider-electric 12 Evlink City Evc1s22p4, Evlink City Evc1s22p4 Firmware, Evlink City Evc1s7p4 and 9 more 2024-11-21 4.0 MEDIUM 6.5 MEDIUM
A CWE-200: Information Exposure vulnerability exists in EVlink City (EVC1S22P4 / EVC1S7P4 all versions prior to R8 V3.4.0.1), EVlink Parking (EVW2 / EVF2 / EV.2 all versions prior to R8 V3.4.0.1), and EVlink Smart Wallbox (EVB1A all versions prior to R8 V3.4.0.1 ) that could cause disclosure of encrypted credentials when consulting the maintenance report.