Total
1024 CVE
CVE | Vendors | Products | Updated | CVSS v2 | CVSS v3 |
---|---|---|---|---|---|
CVE-2021-23019 | 1 F5 | 1 Nginx Controller | 2024-11-21 | 6.9 MEDIUM | 7.8 HIGH |
The NGINX Controller 2.0.0 thru 2.9.0 and 3.x before 3.15.0 Administrator password may be exposed in the systemd.txt file that is included in the NGINX support package. | |||||
CVE-2021-22923 | 6 Fedoraproject, Haxx, Netapp and 3 more | 23 Fedora, Curl, Cloud Backup and 20 more | 2024-11-21 | 2.6 LOW | 5.3 MEDIUM |
When curl is instructed to get content using the metalink feature, and a user name and password are used to download the metalink XML file, those same credentials are then subsequently passed on to each of the servers from which curl will download or try to download the contents from. Often contrary to the user's expectations and intentions and without telling the user it happened. | |||||
CVE-2021-22798 | 1 Schneider-electric | 2 Conext Combox, Conext Combox Firmware | 2024-11-21 | 5.0 MEDIUM | 7.5 HIGH |
A CWE-522: Insufficiently Protected Credentials vulnerability exists that could cause Sensitive data such as login credentials being exposed when a Network is sniffed. Affected Product: Conext? ComBox (All Versions) | |||||
CVE-2021-22781 | 1 Schneider-electric | 3 Ecostruxure Control Expert, Ecostruxure Process Expert, Remoteconnect | 2024-11-21 | 2.1 LOW | 5.5 MEDIUM |
Insufficiently Protected Credentials vulnerability exists in EcoStruxure Control Expert (all versions prior to V15.0 SP1, including all versions of Unity Pro), EcoStruxure Process Expert (all versions, including all versions of EcoStruxure Hybrid DCS), and SCADAPack RemoteConnect for x70, all versions, that could cause a leak of SMTP credential used for mailbox authentication when an attacker can access a project file. | |||||
CVE-2021-22780 | 1 Schneider-electric | 3 Ecostruxure Control Expert, Ecostruxure Process Expert, Remoteconnect | 2024-11-21 | 3.6 LOW | 7.1 HIGH |
Insufficiently Protected Credentials vulnerability exists in EcoStruxure Control Expert (all versions prior to V15.0 SP1, including all versions of Unity Pro), EcoStruxure Process Expert (all versions, including all versions of EcoStruxure Hybrid DCS), and SCADAPack RemoteConnect for x70, all versions, that could cause unauthorized access to a project file protected by a password when this file is shared with untrusted sources. An attacker may bypass the password protection and be able to view and modify a project file. | |||||
CVE-2021-22778 | 1 Schneider-electric | 3 Ecostruxure Control Expert, Ecostruxure Process Expert, Remoteconnect | 2024-11-21 | 3.6 LOW | 7.1 HIGH |
Insufficiently Protected Credentials vulnerability exists in EcoStruxure Control Expert (all versions prior to V15.0 SP1, including all versions of Unity Pro), EcoStruxure Process Expert (all versions, including all versions of EcoStruxure Hybrid DCS), and SCADAPack RemoteConnect for x70, all versions, that could cause protected derived function blocks to be read or modified by unauthorized users when accessing a project file. | |||||
CVE-2021-22681 | 1 Rockwellautomation | 20 Compact Guardlogix 5370, Compact Guardlogix 5380, Compactlogix 1768 and 17 more | 2024-11-21 | 7.5 HIGH | 9.8 CRITICAL |
Rockwell Automation Studio 5000 Logix Designer Versions 21 and later, and RSLogix 5000 Versions 16 through 20 use a key to verify Logix controllers are communicating with Rockwell Automation CompactLogix 1768, 1769, 5370, 5380, 5480: ControlLogix 5550, 5560, 5570, 5580; DriveLogix 5560, 5730, 1794-L34; Compact GuardLogix 5370, 5380; GuardLogix 5570, 5580; SoftLogix 5800. Rockwell Automation Studio 5000 Logix Designer Versions 21 and later and RSLogix 5000: Versions 16 through 20 are vulnerable because an unauthenticated attacker could bypass this verification mechanism and authenticate with Rockwell Automation CompactLogix 1768, 1769, 5370, 5380, 5480: ControlLogix 5550, 5560, 5570, 5580; DriveLogix 5560, 5730, 1794-L34; Compact GuardLogix 5370, 5380; GuardLogix 5570, 5580; SoftLogix 5800. | |||||
CVE-2021-22132 | 2 Elastic, Oracle | 2 Elasticsearch, Communications Cloud Native Core Automated Test Suite | 2024-11-21 | 2.1 LOW | 4.8 MEDIUM |
Elasticsearch versions 7.7.0 to 7.10.1 contain an information disclosure flaw in the async search API. Users who execute an async search will improperly store the HTTP headers. An Elasticsearch user with the ability to read the .tasks index could obtain sensitive request headers of other users in the cluster. This issue is fixed in Elasticsearch 7.10.2 | |||||
CVE-2021-22115 | 1 Cloudfoundry | 2 Capi-release, Cf-deployment | 2024-11-21 | 4.0 MEDIUM | 6.5 MEDIUM |
Cloud Controller API versions prior to 1.106.0 logs service broker credentials if the default value of db logging config field is changed. CAPI database logs service broker password in plain text whenever a job to clean up orphaned items is run by Cloud Controller. | |||||
CVE-2021-21681 | 1 Jenkins | 1 Nomad | 2024-11-21 | 2.1 LOW | 5.5 MEDIUM |
Jenkins Nomad Plugin 0.7.4 and earlier stores Docker passwords unencrypted in the global config.xml file on the Jenkins controller where they can be viewed by users with access to the Jenkins controller file system. | |||||
CVE-2021-21634 | 1 Jenkins | 1 Jabber \(xmpp\) Notifier And Control | 2024-11-21 | 4.0 MEDIUM | 6.5 MEDIUM |
Jenkins Jabber (XMPP) notifier and control Plugin 1.41 and earlier stores passwords unencrypted in its global configuration file on the Jenkins controller where they can be viewed by users with access to the Jenkins controller file system. | |||||
CVE-2021-21614 | 1 Jenkins | 1 Bumblebee Hp Alm | 2024-11-21 | 2.1 LOW | 5.5 MEDIUM |
Jenkins Bumblebee HP ALM Plugin 4.1.5 and earlier stores credentials unencrypted in its global configuration file on the Jenkins controller where they can be viewed by users with access to the Jenkins controller file system. | |||||
CVE-2021-21612 | 1 Jenkins | 1 Tracetronic Ecu-test | 2024-11-21 | 2.1 LOW | 5.5 MEDIUM |
Jenkins TraceTronic ECU-TEST Plugin 2.23.1 and earlier stores credentials unencrypted in its global configuration file on the Jenkins controller where they can be viewed by users with access to the Jenkins controller file system. | |||||
CVE-2021-21591 | 1 Dell | 3 Emc Unity Operating Environment, Emc Unity Xt Operating Environment, Emc Unityvsa Operating Environment | 2024-11-21 | 4.6 MEDIUM | 6.4 MEDIUM |
Dell EMC Unity, Unity XT, and UnityVSA versions prior to 5.1.0.0.5.394 contain a plain-text password storage vulnerability. A local malicious user with high privileges may use the exposed password to gain access with the privileges of the compromised user. | |||||
CVE-2021-21590 | 1 Dell | 3 Emc Unity Operating Environment, Emc Unity Xt Operating Environment, Emc Unityvsa Operating Environment | 2024-11-21 | 4.6 MEDIUM | 6.4 MEDIUM |
Dell EMC Unity, Unity XT, and UnityVSA versions prior to 5.1.0.0.5.394 contain a plain-text password storage vulnerability. A local malicious user with high privileges may use the exposed password to gain access with the privileges of the compromised user. | |||||
CVE-2021-20997 | 1 Wago | 10 0852-0303, 0852-0303 Firmware, 0852-1305 and 7 more | 2024-11-21 | 5.0 MEDIUM | 7.5 HIGH |
In multiple managed switches by WAGO in different versions it is possible to read out the password hashes of all Web-based Management users. | |||||
CVE-2021-20826 | 1 Idec | 7 Data File Manager, Microsmart Fc6a, Microsmart Fc6a Firmware and 4 more | 2024-11-21 | 3.3 LOW | 7.6 HIGH |
Unprotected transport of credentials vulnerability in IDEC PLCs (FC6A Series MICROSmart All-in-One CPU module v2.32 and earlier, FC6A Series MICROSmart Plus CPU module v1.91 and earlier, WindLDR v8.19.1 and earlier, WindEDIT Lite v1.3.1 and earlier, and Data File Manager v2.12.1 and earlier) allows an attacker to obtain the PLC Web server user credentials from the communication between the PLC and the software. As a result, the complete access privileges to the PLC Web server may be obtained, and manipulation of the PLC output and/or suspension of the PLC may be conducted. | |||||
CVE-2021-20597 | 1 Mitsubishielectric | 16 R08psfcpu, R08psfcpu Firmware, R08sfcpu and 13 more | 2024-11-21 | 6.4 MEDIUM | 9.1 CRITICAL |
Insufficiently Protected Credentials vulnerability in Mitsubishi Electric MELSEC iQ-R series Safety CPU modules R08/16/32/120SFCPU firmware versions "26" and prior and Mitsubishi Electric MELSEC iQ-R series SIL2 Process CPU modules R08/16/32/120PSFCPU firmware versions "11" and prior allows a remote unauthenticated attacker to login to the target unauthorizedly by sniffing network traffic and obtaining credentials when registering user information in the target or changing a password. | |||||
CVE-2021-20445 | 3 Ibm, Linux, Microsoft | 3 Maximo For Civil Infrastructure, Linux Kernel, Windows | 2024-11-21 | 4.0 MEDIUM | 6.5 MEDIUM |
IBM Maximo for Civil Infrastructure 7.6.2 could allow a user to obtain sensitive information due to insecure storeage of authentication credentials. IBM X-Force ID: 196621. | |||||
CVE-2021-20439 | 1 Ibm | 2 Security Access Manager, Security Verify Access | 2024-11-21 | 5.0 MEDIUM | 7.5 HIGH |
IBM Security Access Manager 9.0 and IBM Security Verify Access Docker 10.0.0 stores user credentials in plain clear text which can be read by an unauthorized user. |