CVE-2022-33321 | 1 Mitsubishielectric | 356 Ma-ew85s-e, Ma-ew85s-e Firmware, Ma-ew85s-uk and 353 more | 2024-11-21 | N/A | 9.8 CRITICAL |
Cleartext Transmission of Sensitive Information vulnerability due to the use of Basic Authentication for HTTP connections in Mitsubishi Electric consumer electronics products (PHOTOVOLTAIC COLOR MONITOR ECO-GUIDE, HEMS adapter, Wi-Fi Interface, Air Conditioning, Induction hob, Mitsubishi Electric HEMS Energy Measurement Unit, Refrigerator, Remote control with Wi-Fi Interface, BATHROOM THERMO VENTILATOR, Rice cooker, Mitsubishi Electric HEMS control adapter, Energy Recovery Ventilator, Smart Switch, Ventilating Fan, Range hood fan, Energy Measurement Unit and Air Purifier) allows a remote unauthenticated attacker to disclose information in the products or cause a denial of service (DoS) condition as a result by sniffing credential information (username and password). The wide range of models/versions of Mitsubishi Electric consumer electronics products are affected by this vulnerability. As for the affected product models/versions, see the Mitsubishi Electric's advisory which is listed in [References] section. | |||||
CVE-2022-32510 | 2024-11-21 | N/A | 7.1 HIGH | ||
An issue was discovered on certain Nuki Home Solutions devices. The HTTP API exposed by a Bridge used an unencrypted channel to provide an administrative interface. A token can be easily eavesdropped by a malicious actor to impersonate a legitimate user and gain access to the full set of API endpoints. This affects Nuki Bridge v1 before 1.22.0 and v2 before 2.13.2. | |||||
CVE-2022-32245 | 1 Sap | 1 Businessobjects Business Intelligence | 2024-11-21 | N/A | 8.2 HIGH |
SAP BusinessObjects Business Intelligence Platform (Open Document) - versions 420, 430, allows an unauthenticated attacker to retrieve sensitive information plain text over the network. On successful exploitation, the attacker can view any data available for a business user and put load on the application by an automated attack. Thus, completely compromising confidentiality but causing a limited impact on the availability of the application. | |||||
CVE-2022-32227 | 1 Rocket.chat | 1 Rocket.chat | 2024-11-21 | N/A | 6.5 MEDIUM |
A cleartext transmission of sensitive information exists in Rocket.Chat <v5, <v4.8.2 and <v4.7.5 relating to Oauth tokens by having the permission "view-full-other-user-info", this could cause an oauth token leak in the product. | |||||
CVE-2022-31204 | 1 Omron | 15 Cp1w-cif41, Cp1w-cif41 Firmware, Cx-programmer and 12 more | 2024-11-21 | N/A | 7.5 HIGH |
Omron CS series, CJ series, and CP series PLCs through 2022-05-18 use cleartext passwords. They feature a UM Protection setting that allows users or system integrators to configure a password in order to restrict sensitive engineering operations (such as project/logic uploads and downloads). This password is set using the OMRON FINS command Program Area Protect and unset using the command Program Area Protect Clear, both of which are transmitted in cleartext. | |||||
CVE-2022-31046 | 1 Typo3 | 1 Typo3 | 2024-11-21 | 4.0 MEDIUM | 4.3 MEDIUM |
TYPO3 is an open source web content management system. Prior to versions 7.6.57 ELTS, 8.7.47 ELTS, 9.5.34 ELTS, 10.4.29, and 11.5.11, the export functionality fails to limit the result set to allowed columns of a particular database table. This way, authenticated users can export internal details of database tables they already have access to. TYPO3 versions 7.6.57 ELTS, 8.7.47 ELTS, 9.5.34 ELTS, 10.4.29, 11.5.11 fix the problem described above. In order to address this issue, access to mentioned export functionality is completely denied for regular backend users. | |||||
CVE-2022-30994 | 3 Acronis, Linux, Microsoft | 3 Cyber Protect, Linux Kernel, Windows | 2024-11-21 | 5.0 MEDIUM | 7.5 HIGH |
Cleartext transmission of sensitive information. The following products are affected: Acronis Cyber Protect 15 (Windows) before build 29240 | |||||
CVE-2022-30993 | 3 Acronis, Linux, Microsoft | 3 Cyber Protect, Linux Kernel, Windows | 2024-11-21 | 5.0 MEDIUM | 7.5 HIGH |
Cleartext transmission of sensitive information. The following products are affected: Acronis Cyber Protect 15 (Linux, Windows) before build 29240 | |||||
CVE-2022-30312 | 1 Honeywell | 10 Trend Iq411, Trend Iq411 Firmware, Trend Iq412 and 7 more | 2024-11-21 | N/A | 6.5 MEDIUM |
The Trend Controls IC protocol through 2022-05-06 allows Cleartext Transmission of Sensitive Information. According to FSCT-2022-0050, there is a Trend Controls Inter-Controller (IC) protocol cleartext transmission of credentials issue. The affected components are characterized as: Inter-Controller (IC) protocol (57612/UDP). The potential impact is: Compromise of credentials. Several Trend Controls building automation controllers utilize the Inter-Controller (IC) protocol in for information exchange and automation purposes. This protocol offers authentication in the form of a 4-digit PIN in order to protect access to sensitive operations like strategy uploads and downloads as well as optional 0-30 character username and password protection for web page access protection. Both the PIN and usernames and passwords are transmitted in cleartext, allowing an attacker with passive interception capabilities to obtain these credentials. Credentials are transmitted in cleartext. An attacker who obtains Trend IC credentials can carry out sensitive engineering actions such as manipulating controller strategy or configuration settings. If the credentials in question are (re)used for other applications, their compromise could potentially facilitate lateral movement. | |||||
CVE-2022-30115 | 3 Haxx, Netapp, Splunk | 15 Curl, Clustered Data Ontap, H300s and 12 more | 2024-11-21 | 4.0 MEDIUM | 4.3 MEDIUM |
Using its HSTS support, curl can be instructed to use HTTPS directly insteadof using an insecure clear-text HTTP step even when HTTP is provided in theURL. This mechanism could be bypassed if the host name in the given URL used atrailing dot while not using one when it built the HSTS cache. Or the otherway around - by having the trailing dot in the HSTS cache and *not* using thetrailing dot in the URL. | |||||
CVE-2022-2485 | 1 Automationdirect | 20 Sio-mb04ads, Sio-mb04ads Firmware, Sio-mb04das and 17 more | 2024-11-21 | N/A | 9.6 CRITICAL |
Any attempt (good or bad) to log into AutomationDirect Stride Field I/O with a web browser may result in the device responding with its password in the communication packets. | |||||
CVE-2022-2338 | 1 Softing | 6 Edgeaggregator, Edgeconnector, Opc and 3 more | 2024-11-21 | N/A | 5.7 MEDIUM |
Softing Secure Integration Server V1.22 is vulnerable to authentication bypass via a machine-in-the-middle attack. The default the administration interface is accessible via plaintext HTTP protocol, facilitating the attack. The HTTP request may contain the session cookie in the request, which may be captured for use in authenticating to the server. | |||||
CVE-2022-2005 | 1 Automationdirect | 24 C-more Ea9-pgmsw, C-more Ea9-pgmsw Firmware, C-more Ea9-rhmi and 21 more | 2024-11-21 | N/A | 7.5 HIGH |
AutomationDirect C-more EA9 HTTP webserver uses an insecure mechanism to transport credentials from client to web server, which may allow an attacker to obtain the login credentials and login as a valid user. This issue affects: AutomationDirect C-more EA9 EA9-T6CL versions prior to 6.73; EA9-T6CL-R versions prior to 6.73; EA9-T7CL versions prior to 6.73; EA9-T7CL-R versions prior to 6.73; EA9-T8CL versions prior to 6.73; EA9-T10CL versions prior to 6.73; EA9-T10WCL versions prior to 6.73; EA9-T12CL versions prior to 6.73; EA9-T15CL versions prior to 6.73; EA9-RHMI versions prior to 6.73; EA9-PGMSW versions prior to 6.73; | |||||
CVE-2022-2003 | 1 Automationdirect | 18 D0-06aa, D0-06aa Firmware, D0-06ar and 15 more | 2024-11-21 | N/A | 7.7 HIGH |
AutomationDirect DirectLOGIC is vulnerable to a specifically crafted serial message to the CPU serial port that will cause the PLC to respond with the PLC password in cleartext. This could allow an attacker to access and make unauthorized changes. This issue affects: AutomationDirect DirectLOGIC D0-06 series CPUs D0-06DD1 versions prior to 2.72; D0-06DD2 versions prior to 2.72; D0-06DR versions prior to 2.72; D0-06DA versions prior to 2.72; D0-06AR versions prior to 2.72; D0-06AA versions prior to 2.72; D0-06DD1-D versions prior to 2.72; D0-06DD2-D versions prior to 2.72; D0-06DR-D versions prior to 2.72; | |||||
CVE-2022-29945 | 1 Dji | 22 Air 2, Air 2 Firmware, Air 2s and 19 more | 2024-11-21 | 5.0 MEDIUM | 4.0 MEDIUM |
DJI drone devices sold in 2017 through 2022 broadcast unencrypted information about the drone operator's physical location via the AeroScope protocol. | |||||
CVE-2022-29874 | 1 Siemens | 72 7kg8500-0aa00-0aa0, 7kg8500-0aa00-0aa0 Firmware, 7kg8500-0aa00-2aa0 and 69 more | 2024-11-21 | 5.0 MEDIUM | 7.5 HIGH |
A vulnerability has been identified in SICAM P850 (All versions < V3.00), SICAM P850 (All versions < V3.00), SICAM P850 (All versions < V3.00), SICAM P850 (All versions < V3.00), SICAM P850 (All versions < V3.00), SICAM P850 (All versions < V3.00), SICAM P850 (All versions < V3.00), SICAM P850 (All versions < V3.00), SICAM P850 (All versions < V3.00), SICAM P850 (All versions < V3.00), SICAM P850 (All versions < V3.00), SICAM P850 (All versions < V3.00), SICAM P850 (All versions < V3.00), SICAM P850 (All versions < V3.00), SICAM P850 (All versions < V3.00), SICAM P850 (All versions < V3.00), SICAM P850 (All versions < V3.00), SICAM P850 (All versions < V3.00), SICAM P855 (All versions < V3.00), SICAM P855 (All versions < V3.00), SICAM P855 (All versions < V3.00), SICAM P855 (All versions < V3.00), SICAM P855 (All versions < V3.00), SICAM P855 (All versions < V3.00), SICAM P855 (All versions < V3.00), SICAM P855 (All versions < V3.00), SICAM P855 (All versions < V3.00), SICAM P855 (All versions < V3.00), SICAM P855 (All versions < V3.00), SICAM P855 (All versions < V3.00), SICAM P855 (All versions < V3.00), SICAM P855 (All versions < V3.00), SICAM P855 (All versions < V3.00), SICAM P855 (All versions < V3.00), SICAM P855 (All versions < V3.00), SICAM P855 (All versions < V3.00). Affected devices do not encrypt web traffic with clients but communicate in cleartext via HTTP. This could allow an unauthenticated attacker to capture the traffic and interfere with the functionality of the device. | |||||
CVE-2022-29733 | 1 Deltacontrols | 2 Entelitouch, Entelitouch Firmware | 2024-11-21 | 4.3 MEDIUM | 5.9 MEDIUM |
Delta Controls enteliTOUCH 3.40.3935, 3.40.3706, and 3.33.4005 was discovered to transmit and store sensitive information in cleartext. This vulnerability allows attackers to intercept HTTP Cookie authentication credentials via a man-in-the-middle attack. | |||||
CVE-2022-29519 | 1 Yokogawa | 4 Stardom Fcj, Stardom Fcj Firmware, Stardom Fcn and 1 more | 2024-11-21 | 7.9 HIGH | 7.5 HIGH |
Cleartext transmission of sensitive information vulnerability exists in STARDOM FCN Controller and FCJ Controller R1.01 to R4.31, which may allow an adjacent attacker to login the affected products and alter device configuration settings or tamper with device firmware. | |||||
CVE-2022-28861 | 2 Axis, Citilog | 2 M1125, Citilog | 2024-11-21 | N/A | 5.9 MEDIUM |
The server in Citilog 8.0 allows an attacker (in a man in the middle position between the server and its smart camera Axis M1125) to see FTP credentials in a cleartext HTTP traffic. These can be used for FTP access to the server. | |||||
CVE-2022-27619 | 1 Synology | 1 Note Station | 2024-11-21 | N/A | 6.8 MEDIUM |
Cleartext transmission of sensitive information vulnerability in authentication management in Synology Note Station Client before 2.2.2-609 allows man-in-the-middle attackers to obtain sensitive information via unspecified vectors. |