Vulnerabilities (CVE)

Filtered by vendor Trianglemicroworks Subscribe
Total 12 CVE
CVE Vendors Products Updated CVSS v2 CVSS v3
CVE-2014-2343 1 Trianglemicroworks 1 Scada Data Gateway 2024-11-21 2.1 LOW N/A
Triangle MicroWorks SCADA Data Gateway before 3.00.0635 allows physically proximate attackers to cause a denial of service (excessive data processing) via a crafted DNP request over a serial line.
CVE-2014-2342 1 Trianglemicroworks 1 Scada Data Gateway 2024-11-21 5.0 MEDIUM N/A
Triangle MicroWorks SCADA Data Gateway before 3.00.0635 allows remote attackers to cause a denial of service (excessive data processing) via a crafted DNP3 packet.
CVE-2013-2794 1 Trianglemicroworks 3 .net Communication Protocol Components, Ansi C Source Code Libraries, Scada Data Gateway 2024-11-21 4.9 MEDIUM N/A
Triangle MicroWorks SCADA Data Gateway 2.50.0309 through 3.00.0616, DNP3 .NET Protocol components 3.06.0.171 through 3.15.0.369, and DNP3 C libraries 3.06.0000 through 3.15.0000 allow physically proximate attackers to cause a denial of service (infinite loop) via crafted input over a serial line.
CVE-2013-2793 1 Trianglemicroworks 3 .net Communication Protocol Components, Ansi C Source Code Libraries, Scada Data Gateway 2024-11-21 7.8 HIGH N/A
Triangle MicroWorks SCADA Data Gateway 2.50.0309 through 3.00.0616, DNP3 .NET Protocol components 3.06.0.171 through 3.15.0.369, and DNP3 C libraries 3.06.0000 through 3.15.0000 allow remote attackers to cause a denial of service (infinite loop) via a crafted DNP3 TCP packet.
CVE-2024-34057 2 Siemens, Trianglemicroworks 9 Sicam A8000, Sicam A8000 Firmware, Sicam Egs and 6 more 2024-09-25 N/A 7.5 HIGH
Triangle Microworks TMW IEC 61850 Client source code libraries before 12.2.0 lack a buffer size check when processing received messages. The resulting buffer overflow can cause a crash, resulting in a denial of service.
CVE-2023-2186 1 Trianglemicroworks 1 Scada Data Gateway 2024-02-28 N/A 9.8 CRITICAL
On Triangle MicroWorks' SCADA Data Gateway version <= v5.01.03, an unauthenticated attacker can send a specially crafted broadcast message including format string characters to the SCADA Data Gateway to perform unrestricted memory reads.An unauthenticated user can use this format string vulnerability to repeatedly crash the GTWWebMonitor.exe process to DoS the Web Monitor. Furthermore, an authenticated user can leverage this vulnerability to leak memory from the GTWWebMonitor.exe process. This could be leveraged in an exploit chain to gain code execution.
CVE-2023-2187 1 Trianglemicroworks 1 Scada Data Gateway 2024-02-28 N/A 5.3 MEDIUM
On Triangle MicroWorks' SCADA Data Gateway version <= v5.01.03, an unauthenticated attacker can send broadcast events to any user via the WebMonitor.An unauthenticated user can use this vulnerability to forcefully log out of any currently logged-in user by sending a "password change event". Furthermore, an attacker could use this vulnerability to spam the logged-in user with false events.
CVE-2022-38138 1 Trianglemicroworks 2 Iec 60870-6 Software Library, Iec 61850 Software Library 2024-02-28 N/A 7.5 HIGH
The Triangle Microworks IEC 61850 Library (Any client or server using the C language library with a version number of 11.2.0 or earlier and any client or server using the C++, C#, or Java language library with a version number of 5.0.1 or earlier) and 60870-6 (ICCP/TASE.2) Library (Any client or server using a C++ language library with a version number of 4.4.3 or earlier) are vulnerable to access given to a small number of uninitialized pointers within their code. This could allow an attacker to target any client or server using the affected libraries to cause a denial-of-service condition.
CVE-2020-6996 1 Trianglemicroworks 1 Dnp3 Source Code Library 2024-02-28 7.5 HIGH 9.8 CRITICAL
Triangle MicroWorks DNP3 Outstation LibrariesDNP3 Outstation .NET Protocol components and DNP3 Outstation ANSI C source code libraries are affected:3.16.00 through 3.25.01. A specially crafted message may cause a stack-based buffer overflow. Authentication is not required to exploit this vulnerability.
CVE-2020-10611 1 Trianglemicroworks 1 Scada Data Gateway 2024-02-28 7.5 HIGH 9.8 CRITICAL
Triangle MicroWorks SCADA Data Gateway 3.02.0697 through 4.0.122, 2.41.0213 through 4.0.122 allows remote attackers to execute arbitrary code due to the lack of proper validation of user-supplied data, which can result in a type confusion condition. Authentication is not required to exploit this vulnerability. Only applicable to installations using DNP3 Data Sets.
CVE-2020-10613 1 Trianglemicroworks 1 Scada Data Gateway 2024-02-28 5.0 MEDIUM 7.5 HIGH
Triangle MicroWorks SCADA Data Gateway 3.02.0697 through 4.0.122, 2.41.0213 through 4.0.122 allows remote attackers to disclose sensitive information due to the lack of proper validation of user-supplied data, which can result in a read past the end of an allocated structure. Authentication is not required to exploit this vulnerability. Only applicable to installations using DNP3 Data Sets.
CVE-2020-10615 1 Trianglemicroworks 1 Scada Data Gateway 2024-02-28 5.0 MEDIUM 7.5 HIGH
Triangle MicroWorks SCADA Data Gateway 3.02.0697 through 4.0.122, 2.41.0213 through 4.0.122 allows remote attackers cause a denial-of-service condition due to a lack of proper validation of the length of user-supplied data, prior to copying it to a fixed-length stack-based buffer. Authentication is not required to exploit this vulnerability.