Vulnerabilities (CVE)

Filtered by vendor Tendacn Subscribe
Total 145 CVE
CVE Vendors Products Updated CVSS v2 CVSS v3
CVE-2024-50853 1 Tendacn 2 G3, G3 Firmware 2024-11-21 N/A 8.8 HIGH
Tenda G3 v3.0 v15.11.0.20 was discovered to contain a command injection vulnerability via the formSetDebugCfg function.
CVE-2024-50852 1 Tendacn 2 G3, G3 Firmware 2024-11-21 N/A 8.8 HIGH
Tenda G3 v3.0 v15.11.0.20 was discovered to contain a command injection vulnerability via the formSetUSBPartitionUmount function.
CVE-2024-6403 1 Tendacn 2 A301, A301 Firmware 2024-11-21 6.8 MEDIUM 6.5 MEDIUM
A vulnerability, which was classified as critical, has been found in Tenda A301 15.13.08.12. Affected by this issue is the function formWifiBasicSet of the file /goform/SetOnlineDevName. The manipulation of the argument devName leads to stack-based buffer overflow. The attack may be launched remotely. The exploit has been disclosed to the public and may be used. The identifier of this vulnerability is VDB-269948. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
CVE-2024-6402 1 Tendacn 2 A301, A301 Firmware 2024-11-21 6.8 MEDIUM 6.5 MEDIUM
A vulnerability classified as critical was found in Tenda A301 15.13.08.12. Affected by this vulnerability is the function fromSetWirelessRepeat of the file /goform/SetOnlineDevName. The manipulation of the argument devName leads to stack-based buffer overflow. The attack can be launched remotely. The exploit has been disclosed to the public and may be used. The associated identifier of this vulnerability is VDB-269947. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
CVE-2024-6189 1 Tendacn 2 A301, A301 Firmware 2024-11-21 9.0 HIGH 8.8 HIGH
A vulnerability was found in Tenda A301 15.13.08.12. It has been classified as critical. Affected is the function fromSetWirelessRepeat of the file /goform/WifiExtraSet. The manipulation of the argument wpapsk_crypto leads to stack-based buffer overflow. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used. The identifier of this vulnerability is VDB-269160. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
CVE-2024-41473 1 Tendacn 2 Fh1201, Fh1201 Firmware 2024-11-21 N/A 9.8 CRITICAL
Tenda FH1201 v1.2.0.14 was discovered to contain a command injection vulnerability via the mac parameter at ip/goform/WriteFacMac
CVE-2024-41468 1 Tendacn 2 Fh1201, Fh1201 Firmware 2024-11-21 N/A 9.8 CRITICAL
Tenda FH1201 v1.2.0.14 was discovered to contain a command injection vulnerability via the cmdinput parameter at /goform/exeCommand
CVE-2024-41466 1 Tendacn 2 Fh1201, Fh1201 Firmware 2024-11-21 N/A 7.5 HIGH
Tenda FH1201 v1.2.0.14 was discovered to contain a stack-based buffer overflow vulnerability via the page parameter at ip/goform/NatStaticSetting.
CVE-2024-41465 1 Tendacn 2 Fh1201, Fh1201 Firmware 2024-11-21 N/A 7.5 HIGH
Tenda FH1201 v1.2.0.14 was discovered to contain a stack-based buffer overflow vulnerability via the funcpara1 parameter at ip/goform/setcfm.
CVE-2024-41464 1 Tendacn 2 Fh1201, Fh1201 Firmware 2024-11-21 N/A 7.5 HIGH
Tenda FH1201 v1.2.0.14 was discovered to contain a stack-based buffer overflow vulnerability via the mitInterface parameter in ip/goform/RouteStatic
CVE-2024-41463 1 Tendacn 2 Fh1201, Fh1201 Firmware 2024-11-21 N/A 7.5 HIGH
Tenda FH1201 v1.2.0.14 was discovered to contain a stack-based buffer overflow vulnerability via the entrys parameter at ip/goform/addressNat.
CVE-2024-41462 1 Tendacn 2 Fh1201, Fh1201 Firmware 2024-11-21 N/A 7.5 HIGH
Tenda FH1201 v1.2.0.14 was discovered to contain a stack-based buffer overflow vulnerability via the page parameter at ip/goform/DhcpListClient.
CVE-2024-41461 1 Tendacn 2 Fh1201, Fh1201 Firmware 2024-11-21 N/A 9.8 CRITICAL
Tenda FH1201 v1.2.0.14 was discovered to contain a stack-based buffer overflow vulnerability via the list1 parameter at ip/goform/DhcpListClient.
CVE-2024-41460 1 Tendacn 2 Fh1201, Fh1201 Firmware 2024-11-21 N/A 9.8 CRITICAL
Tenda FH1201 v1.2.0.14 was discovered to contain a stack-based buffer overflow vulnerability via the entrys parameter at ip/goform/RouteStatic.
CVE-2024-41459 1 Tendacn 2 Fh1201, Fh1201 Firmware 2024-11-21 N/A 9.8 CRITICAL
Tenda FH1201 v1.2.0.14 was discovered to contain a stack-based buffer overflow vulnerability via the PPPOEPassword parameter at ip/goform/QuickIndex.
CVE-2024-36604 1 Tendacn 2 O3v2, O3v2 Firmware 2024-11-21 N/A 9.8 CRITICAL
Tenda O3V2 v1.0.0.12(3880) was discovered to contain a Blind Command Injection via stpEn parameter in the SetStp function. This vulnerability allows attackers to execute arbitrary commands with root privileges.
CVE-2024-35338 1 Tendacn 2 I29, I29 Firmware 2024-11-21 N/A 9.8 CRITICAL
Tenda i29V1.0 V1.0.0.5 was discovered to contain a hardcoded password for root.
CVE-2024-33182 1 Tendacn 2 Ac18, Ac18 Firmware 2024-11-21 N/A 9.8 CRITICAL
Tenda AC18 V15.03.3.10_EN was discovered to contain a stack-based buffer overflow vulnerability via the deviceId parameter at ip/goform/addWifiMacFilter.
CVE-2024-33180 1 Tendacn 2 Ac18, Ac18 Firmware 2024-11-21 N/A 9.8 CRITICAL
Tenda AC18 V15.03.3.10_EN was discovered to contain a stack-based buffer overflow vulnerability via the deviceId parameter at ip/goform/saveParentControlInfo.
CVE-2024-24488 1 Tendacn 2 Cp3, Cp3 Firmware 2024-11-21 N/A 5.5 MEDIUM
An issue in Shenzen Tenda Technology CP3V2.0 V11.10.00.2311090948 allows a local attacker to obtain sensitive information via the password component.