Vulnerabilities (CVE)

Filtered by vendor Pragma Systems Subscribe
Total 10 CVE
CVE Vendors Products Updated CVSS v2 CVSS v3
CVE-2008-0153 1 Pragma Systems 1 Pragma Telnetserver 2024-11-21 5.0 MEDIUM N/A
telnetd.exe in Pragma TelnetServer 7.0.4.589 allows remote attackers to cause a denial of service (process crash and resource exhaustion) via a crafted TELOPT PRAGMA LOGON telnet option, which triggers a NULL pointer dereference.
CVE-2006-2421 1 Pragma Systems 1 Fortressssh 2024-11-21 7.5 HIGH N/A
Stack-based buffer overflow in Pragma FortressSSH 4.0.7.20 allows remote attackers to execute arbitrary code via long SSH_MSG_KEXINIT messages, which may cause an overflow when being logged. NOTE: the provenance of this information is unknown; the details are obtained solely from third party information.
CVE-2005-1969 1 Pragma Systems 1 Pragma Telnetserver 2024-11-20 4.3 MEDIUM N/A
Cross-site scripting (XSS) vulnerability in Pragma Systems Telnetserver 6.0 allows remote attackers to inject arbitrary web script or HTML, and hide activities in log files, via a "<!--" (HTML comment) in a session.
CVE-2002-1360 7 Cisco, Fissh, Intersoft and 4 more 7 Ios, Ssh Client, Securenetterm and 4 more 2024-11-20 10.0 HIGH N/A
Multiple SSH2 servers and clients do not properly handle strings with null characters in them when the string length is specified by a length field, which could allow remote attackers to cause a denial of service or possibly execute arbitrary code due to interactions with the use of null-terminated strings as implemented using languages such as C, as demonstrated by the SSHredder SSH protocol test suite.
CVE-2002-1359 7 Cisco, Fissh, Intersoft and 4 more 7 Ios, Ssh Client, Securenetterm and 4 more 2024-11-20 10.0 HIGH N/A
Multiple SSH2 servers and clients do not properly handle large packets or large fields, which may allow remote attackers to cause a denial of service or possibly execute arbitrary code via buffer overflow attacks, as demonstrated by the SSHredder SSH protocol test suite.
CVE-2002-1358 7 Cisco, Fissh, Intersoft and 4 more 7 Ios, Ssh Client, Securenetterm and 4 more 2024-11-20 10.0 HIGH N/A
Multiple SSH2 servers and clients do not properly handle lists with empty elements or strings, which may allow remote attackers to cause a denial of service or possibly execute arbitrary code, as demonstrated by the SSHredder SSH protocol test suite.
CVE-2002-1357 7 Cisco, Fissh, Intersoft and 4 more 7 Ios, Ssh Client, Securenetterm and 4 more 2024-11-20 10.0 HIGH N/A
Multiple SSH2 servers and clients do not properly handle packets or data elements with incorrect length specifiers, which may allow remote attackers to cause a denial of service or possibly execute arbitrary code, as demonstrated by the SSHredder SSH protocol test suite.
CVE-2001-1263 1 Pragma Systems 1 Interaccess 2024-11-20 5.0 MEDIUM N/A
telnet95.exe in Pragma InterAccess 4.0 build 5 allows remote attackers to cause a denial of service (crash) via a large number of characters to port 23, possibly due to a buffer overflow.
CVE-2000-0708 1 Pragma Systems 1 Telnetserver 2024-11-20 5.0 MEDIUM N/A
Buffer overflow in Pragma Systems TelnetServer 2000 version 4.0 allows remote attackers to cause a denial of service via a long series of null characters to the rexec port.
CVE-2000-0212 1 Pragma Systems 1 Interaccess Telnetd Server 2024-11-20 5.0 MEDIUM N/A
InterAccess TelnetD Server 4.0 allows remote attackers to conduct a denial of service via malformed terminal client configuration information.