Vulnerabilities (CVE)

Filtered by vendor Flir Subscribe
Total 10 CVE
CVE Vendors Products Updated CVSS v2 CVSS v3
CVE-2023-51127 1 Flir 2 Flir Ax8, Flir Ax8 Firmware 2024-02-28 N/A 7.5 HIGH
FLIR AX8 thermal sensor cameras up to and including 1.46.16 are vulnerable to Directory Traversal due to improper access restriction. This vulnerability allows an unauthenticated, remote attacker to obtain arbitrary sensitive file contents by uploading a specially crafted symbolic link file.
CVE-2023-51126 1 Flir 2 Flir Ax8, Flir Ax8 Firmware 2024-02-28 N/A 9.8 CRITICAL
Command injection vulnerability in /usr/www/res.php in FLIR AX8 up to 1.46.16 allows attackers to run arbitrary commands via the value parameter.
CVE-2023-29861 1 Flir 2 Dvtel Camera, Dvtel Camera Firmware 2024-02-28 N/A 9.8 CRITICAL
An issue found in FLIR-DVTEL version not specified allows a remote attacker to execute arbitrary code via a crafted request to the management page of the device.
CVE-2022-4364 1 Flir 2 Flir Ax8, Flir Ax8 Firmware 2024-02-28 N/A 9.8 CRITICAL
A vulnerability classified as critical has been found in Teledyne FLIR AX8 up to 1.46.16. Affected is an unknown function of the file palette.php of the component Web Service Handler. The manipulation of the argument palette leads to command injection. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used. VDB-215118 is the identifier assigned to this vulnerability.
CVE-2022-37062 1 Flir 2 Flir Ax8, Flir Ax8 Firmware 2024-02-28 N/A 7.5 HIGH
All FLIR AX8 thermal sensor cameras version up to and including 1.46.16 are affected by an insecure design vulnerability due to an improper directory access restriction. An unauthenticated, remote attacker can exploit this by sending a URI that contains the path of the SQLite users database and download it. A successful exploit could allow the attacker to extract usernames and hashed passwords.
CVE-2022-37063 1 Flir 2 Flir Ax8, Flir Ax8 Firmware 2024-02-28 N/A 5.4 MEDIUM
All FLIR AX8 thermal sensor cameras versions up to and including 1.46.16 are vulnerable to Cross Site Scripting (XSS) due to improper input sanitization. An authenticated remote attacker can execute arbitrary JavaScript code in the web management interface. A successful exploit could allow the attacker to insert malicious JavaScript code.
CVE-2022-37060 1 Flir 2 Flir Ax8, Flir Ax8 Firmware 2024-02-28 N/A 7.5 HIGH
FLIR AX8 thermal sensor cameras version up to and including 1.46.16 is vulnerable to Directory Traversal due to an improper access restriction. An unauthenticated, remote attacker can exploit this by sending a URI that contains directory traversal characters to disclose the contents of files located outside of the server's restricted path.
CVE-2022-37061 1 Flir 2 Flir Ax8, Flir Ax8 Firmware 2024-02-28 N/A 9.8 CRITICAL
All FLIR AX8 thermal sensor cameras version up to and including 1.46.16 are vulnerable to Remote Command Injection. This can be exploited to inject and execute arbitrary shell commands as the root user through the id HTTP POST parameter in the res.php endpoint. A successful exploit could allow the attacker to execute arbitrary commands on the underlying operating system with the root privileges.
CVE-2018-12920 1 Flir 2 Brickstream 2300, Brickstream 2300 Firmware 2024-02-28 5.0 MEDIUM 7.5 HIGH
Brickstream 2300 devices allow remote attackers to obtain potentially sensitive information via a direct request for the basic.html#ipsettings or basic.html#datadelivery URI.
CVE-2018-3813 1 Flir 6 Brickstream 2300 2d, Brickstream 2300 2d Firmware, Brickstream 2300 3d and 3 more 2024-02-28 5.0 MEDIUM 9.8 CRITICAL
getConfigExportFile.cgi on FLIR Brickstream 2300 devices 2.0 4.1.53.166 has Incorrect Access Control, as demonstrated by reading the AVI_USER_ID and AVI_USER_PASSWORD fields via a direct request.