Filtered by vendor Hpe
Subscribe
Total
151 CVE
CVE | Vendors | Products | Updated | CVSS v2 | CVSS v3 |
---|---|---|---|---|---|
CVE-2020-7139 | 1 Hpe | 10 Nimble Storage Af20 All Flash Array, Nimble Storage Af20q All Flash Dual Controller, Nimble Storage Af40 All Flash Dual Controller and 7 more | 2024-02-28 | 5.5 MEDIUM | 8.1 HIGH |
Potential remote access security vulnerabilities have been identified with HPE Nimble Storage systems that could be exploited by an attacker to access and modify sensitive information on the system. The following NimbleOS versions, and all subsequent releases, contain a software fix for this vulnerability: 3.9.3.0 4.5.6.0 5.0.9.0 5.1.4.100 | |||||
CVE-2019-12002 | 1 Hpe | 12 Msa 1040, Msa 1040 Firmware, Msa 1050 and 9 more | 2024-02-28 | 10.0 HIGH | 9.8 CRITICAL |
A remote session reuse vulnerability leading to access restriction bypass was discovered in HPE MSA 2040 SAN Storage; HPE MSA 1040 SAN Storage; HPE MSA 1050 SAN Storage; HPE MSA 2042 SAN Storage; HPE MSA 2050 SAN Storage; HPE MSA 2052 SAN Storage version(s): GL225P001 and earlier; GL225P001 and earlier; VE270R001-01 and earlier; GL225P001 and earlier; VL270R001-01 and earlier; VL270R001-01 and earlier. | |||||
CVE-2019-11999 | 1 Hpe | 1 Opencall Media Platform | 2024-02-28 | 4.9 MEDIUM | 6.9 MEDIUM |
Potential security vulnerabilities have been identified in HPE OpenCall Media Platform (OCMP) resulting in remote arbitrary file download and cross site scripting. HPE has made the following updates available to resolve the vulnerability in the impacted versions of OCMP. * For OCMP version 4.4.X - please upgrade to OCMP 4.4.8 and then install RP806 * For OCMP 4.5.x please contact HPE Technical Support to obtain the necessary software updates. | |||||
CVE-2020-7136 | 1 Hpe | 1 Smart Update Manager | 2024-02-28 | 10.0 HIGH | 9.8 CRITICAL |
A security vulnerability in HPE Smart Update Manager (SUM) prior to version 8.5.6 could allow remote unauthorized access. Hewlett Packard Enterprise has provided a software update to resolve this vulnerability in HPE Smart Update Manager (SUM) prior to 8.5.6. Please visit the HPE Support Center at https://support.hpe.com/hpesc/public/home to download the latest version of HPE Smart Update Manager (SUM). Download the latest version of HPE Smart Update Manager (SUM) or download the latest Service Pack For ProLiant (SPP). | |||||
CVE-2020-7205 | 1 Hpe | 118 Apollo 2000 Gen10 Plus System, Apollo 4200 Gen10 Server, Apollo 4200 Gen9 Server and 115 more | 2024-02-28 | 7.2 HIGH | 6.7 MEDIUM |
A potential security vulnerability has been identified in HPE Intelligent Provisioning, Service Pack for ProLiant, and HPE Scripting ToolKit. The vulnerability could be locally exploited to allow arbitrary code execution during the boot process. **Note:** This vulnerability is related to using insmod in GRUB2 in the specific impacted HPE product and HPE is addressing this issue. HPE has made the following software updates and mitigation information to resolve the vulnerability in Intelligent Provisioning, Service Pack for ProLiant, and HPE Scripting ToolKit. HPE provided latest Intelligent Provisioning, Service Pack for ProLiant, and HPE Scripting Toolkit which includes the GRUB2 patch to resolve this vulnerability. These new boot images will update GRUB2 and the Forbidden Signature Database (DBX). After the DBX is updated, users will not be able to boot to the older IP, SPP or Scripting ToolKit with Secure Boot enabled. HPE have provided a standalone DBX update tool to work with Microsoft Windows, and supported Linux Operating Systems. These tools can be used to update the Forbidden Signature Database (DBX) from within the OS. **Note:** This DBX update mitigates the GRUB2 issue with insmod enabled, and the "Boot Hole" issue for HPE signed GRUB2 applications. | |||||
CVE-2019-12001 | 1 Hpe | 12 Msa 1040, Msa 1040 Firmware, Msa 1050 and 9 more | 2024-02-28 | 7.1 HIGH | 6.4 MEDIUM |
A remote session reuse vulnerability leading to access restriction bypass was discovered in HPE MSA 2040 SAN Storage; HPE MSA 1040 SAN Storage; HPE MSA 1050 SAN Storage; HPE MSA 2042 SAN Storage; HPE MSA 2050 SAN Storage; HPE MSA 2052 SAN Storage version(s): GL225P001 and earlier; GL225P001 and earlier; VE270R001-01 and earlier; GL225P001 and earlier; VL270R001-01 and earlier; VL270R001-01 and earlier. | |||||
CVE-2020-7137 | 1 Hpe | 2 Superdome Flex Server, Superdome Flex Server Firmware | 2024-02-28 | 4.6 MEDIUM | 6.7 MEDIUM |
A validation issue in HPE Superdome Flex's RMC component may allow local elevation of privilege. Apply HPE Superdome Flex Server version 3.25.46 or later to resolve this issue. | |||||
CVE-2019-11996 | 1 Hpe | 10 Nimble Storage Af20 All Flash Array, Nimble Storage Af20q All Flash Dual Controller, Nimble Storage Af40 All Flash Dual Controller and 7 more | 2024-02-28 | 10.0 HIGH | 9.8 CRITICAL |
Potential security vulnerabilities have been identified with HPE Nimble Storage systems in multi array group configurations. The vulnerabilities could be exploited by an attacker to gain elevated privileges on the array. The following NimbleOS versions, and all subsequent releases, contain a software fix for this vulnerability: 3.9.2.0, 4.5.5.0, 5.0.8.0 and 5.1.3.0. | |||||
CVE-2019-11137 | 2 Hpe, Intel | 568 Apollo 4200 Gen10 Server, Apollo 4200 Gen10 Server Firmware, Apollo 4200 Gen9 Server and 565 more | 2024-02-28 | 4.6 MEDIUM | 8.2 HIGH |
Insufficient input validation in system firmware for Intel(R) Xeon(R) Scalable Processors, Intel(R) Xeon(R) Processors D Family, Intel(R) Xeon(R) Processors E5 v4 Family, Intel(R) Xeon(R) Processors E7 v4 Family and Intel(R) Atom(R) processor C Series may allow a privileged user to potentially enable escalation of privilege, denial of service and/or information disclosure via local access. | |||||
CVE-2019-11998 | 1 Hpe | 2 Superdome Flex Server, Superdome Flex Server Firmware | 2024-02-28 | 5.0 MEDIUM | 5.5 MEDIUM |
HPE Superdome Flex Server is vulnerable to multiple remote vulnerabilities via improper input validation of administrator commands. This vulnerability could allow an Administrator to bypass security restrictions and access multiple remote vulnerabilities including information disclosure, or denial of service. HPE has provided firmware updates that address the above vulnerabilities for the HPE Superdome Flex Server starting with firmware version v3.20.186 (not available online) and v3.20.206 (available online). Apply v3.20.206 (4 December 2019) or a newer version to resolve this issue. Please visit HPE Support Center https://support.hpe.com/hpesc/public/home to obtain the updated firmware for your product. | |||||
CVE-2019-11136 | 2 Hpe, Intel | 568 Apollo 4200 Gen10 Server, Apollo 4200 Gen10 Server Firmware, Apollo 4200 Gen9 Server and 565 more | 2024-02-28 | 4.6 MEDIUM | 6.7 MEDIUM |
Insufficient access control in system firmware for Intel(R) Xeon(R) Scalable Processors, 2nd Generation Intel(R) Xeon(R) Scalable Processors and Intel(R) Xeon(R) Processors D Family may allow a privileged user to potentially enable escalation of privilege, denial of service and/or information disclosure via local access. | |||||
CVE-2019-11987 | 1 Hpe | 1 Smart Update Manager | 2024-02-28 | 4.6 MEDIUM | 7.8 HIGH |
A security vulnerability in HPE Smart Update Manager (SUM) prior to v8.4 could allow local unauthorized elevation of privilege. | |||||
CVE-2019-11988 | 1 Hpe | 1 Smart Update Manager | 2024-02-28 | 7.5 HIGH | 9.8 CRITICAL |
A Remote Unauthorized Access vulnerability was identified in HPE Smart Update Manager (SUM) earlier than version 8.3.5. | |||||
CVE-2019-8936 | 5 Fedoraproject, Hpe, Netapp and 2 more | 6 Fedora, Hpux-ntp, Clustered Data Ontap and 3 more | 2024-02-28 | 5.0 MEDIUM | 7.5 HIGH |
NTP through 4.2.8p12 has a NULL Pointer Dereference. | |||||
CVE-2018-7094 | 1 Hpe | 1 3par Service Provider | 2024-02-28 | 2.1 LOW | 5.5 MEDIUM |
A security vulnerability was identified in 3PAR Service Processor (SP) prior to SP-5.0.0.0-22913(GA). The vulnerability may be exploited locally to allow disclosure of privileged information. | |||||
CVE-2015-9281 | 6 Hpe, Ibm, Linux and 3 more | 6 Hp-ux Ipfilter, Aix, Linux Kernel and 3 more | 2024-02-28 | 4.3 MEDIUM | 6.1 MEDIUM |
Logon Manager in SAS Web Infrastructure Platform before 9.4M3 allows reflected XSS on the Timeout page. | |||||
CVE-2018-7108 | 1 Hpe | 1 Storageworks Xp7 Automation Director | 2024-02-28 | 4.3 MEDIUM | 5.9 MEDIUM |
HPE StorageWorks XP7 Automation Director (AutoDir) version 8.5.2-02 to earlier than 8.6.1-00 has a local and remote authentication bypass vulnerability that exposed the user authentication information of the storage system. This problem sometimes occurred under specific conditions when running a service template. | |||||
CVE-2018-20733 | 6 Hpe, Ibm, Linux and 3 more | 6 Hp-ux Ipfilter, Aix, Linux Kernel and 3 more | 2024-02-28 | 5.0 MEDIUM | 7.5 HIGH |
BI Web Services in SAS Web Infrastructure Platform before 9.4M6 allows XXE. | |||||
CVE-2018-20732 | 6 Hpe, Ibm, Linux and 3 more | 6 Hp-ux Ipfilter, Aix, Linux Kernel and 3 more | 2024-02-28 | 7.5 HIGH | 9.8 CRITICAL |
SAS Web Infrastructure Platform before 9.4M6 allows remote attackers to execute arbitrary code via a Java deserialization variant. | |||||
CVE-2018-7110 | 2 Hpe, Redhat | 2 Service Governance Framework, Linux | 2024-02-28 | 4.3 MEDIUM | 5.9 MEDIUM |
A remote unauthorized disclosure of information vulnerability was identified in HPE Service Governance Framework (SGF) version 4.2, 4.3. A race condition under high load in SGF exists where SGF transferred different parameter to the enabler. |