Vulnerabilities (CVE)

Filtered by vendor Siemens Subscribe
Total 1853 CVE
CVE Vendors Products Updated CVSS v2 CVSS v3
CVE-2019-18342 1 Siemens 1 Control Center Server 2024-02-28 7.5 HIGH 9.9 CRITICAL
A vulnerability has been identified in Control Center Server (CCS) (All versions < V1.5.0). The SFTP service (default port 22/tcp) of the Control Center Server (CCS) does not properly limit its capabilities to the specified purpose. In conjunction with CVE-2019-18341, an unauthenticated remote attacker with network access to the CCS server could exploit this vulnerability to read or delete arbitrary files, or access other resources on the same server.
CVE-2019-19925 8 Debian, Netapp, Opensuse and 5 more 12 Debian Linux, Cloud Backup, Backports Sle and 9 more 2024-02-28 5.0 MEDIUM 7.5 HIGH
zipfileUpdate in ext/misc/zipfile.c in SQLite 3.30.1 mishandles a NULL pathname during an update of a ZIP archive.
CVE-2019-13933 1 Siemens 14 Scalance X-200rna, Scalance X-200rna Firmware, Scalance X-300 and 11 more 2024-02-28 7.5 HIGH 8.6 HIGH
A vulnerability has been identified in SCALANCE X204RNA (HSR), SCALANCE X204RNA (PRP), SCALANCE X204RNA EEC (HSR), SCALANCE X204RNA EEC (PRP), SCALANCE X204RNA EEC (PRP/HSR), SCALANCE X302-7 EEC (230V), SCALANCE X302-7 EEC (230V, coated), SCALANCE X302-7 EEC (24V), SCALANCE X302-7 EEC (24V, coated), SCALANCE X302-7 EEC (2x 230V), SCALANCE X302-7 EEC (2x 230V, coated), SCALANCE X302-7 EEC (2x 24V), SCALANCE X302-7 EEC (2x 24V, coated), SCALANCE X304-2FE, SCALANCE X306-1LD FE, SCALANCE X307-2 EEC (230V), SCALANCE X307-2 EEC (230V, coated), SCALANCE X307-2 EEC (24V), SCALANCE X307-2 EEC (24V, coated), SCALANCE X307-2 EEC (2x 230V), SCALANCE X307-2 EEC (2x 230V, coated), SCALANCE X307-2 EEC (2x 24V), SCALANCE X307-2 EEC (2x 24V, coated), SCALANCE X307-3, SCALANCE X307-3, SCALANCE X307-3LD, SCALANCE X307-3LD, SCALANCE X308-2, SCALANCE X308-2, SCALANCE X308-2LD, SCALANCE X308-2LD, SCALANCE X308-2LH, SCALANCE X308-2LH, SCALANCE X308-2LH+, SCALANCE X308-2LH+, SCALANCE X308-2M, SCALANCE X308-2M, SCALANCE X308-2M PoE, SCALANCE X308-2M PoE, SCALANCE X308-2M TS, SCALANCE X308-2M TS, SCALANCE X310, SCALANCE X310, SCALANCE X310FE, SCALANCE X310FE, SCALANCE X320-1 FE, SCALANCE X320-1-2LD FE, SCALANCE X408-2, SCALANCE XR324-12M (230V, ports on front), SCALANCE XR324-12M (230V, ports on front), SCALANCE XR324-12M (230V, ports on rear), SCALANCE XR324-12M (230V, ports on rear), SCALANCE XR324-12M (24V, ports on front), SCALANCE XR324-12M (24V, ports on front), SCALANCE XR324-12M (24V, ports on rear), SCALANCE XR324-12M (24V, ports on rear), SCALANCE XR324-12M TS (24V), SCALANCE XR324-12M TS (24V), SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on front), SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on front), SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on rear), SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on rear), SCALANCE XR324-4M EEC (24V, ports on front), SCALANCE XR324-4M EEC (24V, ports on front), SCALANCE XR324-4M EEC (24V, ports on rear), SCALANCE XR324-4M EEC (24V, ports on rear), SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on front), SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on front), SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on rear), SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on rear), SCALANCE XR324-4M EEC (2x 24V, ports on front), SCALANCE XR324-4M EEC (2x 24V, ports on front), SCALANCE XR324-4M EEC (2x 24V, ports on rear), SCALANCE XR324-4M EEC (2x 24V, ports on rear), SCALANCE XR324-4M PoE (230V, ports on front), SCALANCE XR324-4M PoE (230V, ports on rear), SCALANCE XR324-4M PoE (24V, ports on front), SCALANCE XR324-4M PoE (24V, ports on rear), SCALANCE XR324-4M PoE TS (24V, ports on front), SIPLUS NET SCALANCE X308-2. Affected devices contain a vulnerability that allows an unauthenticated attacker to violate access-control rules. The vulnerability can be triggered by sending GET request to specific uniform resource locator on the web configuration interface of the device. The security vulnerability could be exploited by an attacker with network access to the affected systems. An attacker could use the vulnerability to obtain sensitive information or change the device configuration. At the time of advisory publication no public exploitation of this security vulnerability was known.
CVE-2019-18314 1 Siemens 1 Sppa-t3000 Application Server 2024-02-28 7.5 HIGH 9.8 CRITICAL
A vulnerability has been identified in SPPA-T3000 Application Server (All versions < Service Pack R8.2 SP2). An attacker with network access to the Application Server could gain remote code execution by sending specifically crafted objects via RMI. Please note that an attacker needs to have network access to the Application Server in order to exploit this vulnerability. At the time of advisory publication no public exploitation of this security vulnerability was known.
CVE-2019-18290 1 Siemens 1 Sppa-t3000 Ms3000 Migration Server 2024-02-28 5.0 MEDIUM 7.5 HIGH
A vulnerability has been identified in SPPA-T3000 MS3000 Migration Server (All versions). An attacker with network access to the MS3000 Server could trigger a Denial-of-Service condition by sending specifically crafted packets to port 5010/tcp. This vulnerability is independent from CVE-2019-18291, CVE-2019-18292, CVE-2019-18294, CVE-2019-18298, CVE-2019-18299, CVE-2019-18300, CVE-2019-18301, CVE-2019-18302, CVE-2019-18303, CVE-2019-18304, CVE-2019-18305, CVE-2019-18306, and CVE-2019-18307. Please note that an attacker needs to have network access to the MS3000 in order to exploit this vulnerability. At the time of advisory publication no public exploitation of this security vulnerability was known.
CVE-2019-18301 1 Siemens 1 Sppa-t3000 Ms3000 Migration Server 2024-02-28 5.0 MEDIUM 7.5 HIGH
A vulnerability has been identified in SPPA-T3000 MS3000 Migration Server (All versions). An attacker with network access to the MS3000 Server can trigger a Denial-of-Service condition by sending specifically crafted packets to port 5010/tcp. This vulnerability is independent from CVE-2019-18290, CVE-2019-18291, CVE-2019-18292, CVE-2019-18294, CVE-2019-18298, CVE-2019-18299, CVE-2019-18300, CVE-2019-18302, CVE-2019-18303, CVE-2019-18304, CVE-2019-18305, CVE-2019-18306, and CVE-2019-18307. Please note that an attacker needs to have network access to the MS3000 in order to exploit this vulnerability. At the time of advisory publication no public exploitation of this security vulnerability was known.
CVE-2020-9272 3 Opensuse, Proftpd, Siemens 7 Backports Sle, Leap, Proftpd and 4 more 2024-02-28 5.0 MEDIUM 7.5 HIGH
ProFTPD 1.3.7 has an out-of-bounds (OOB) read vulnerability in mod_cap via the cap_text.c cap_to_text function.
CVE-2019-18284 1 Siemens 1 Sppa-t3000 Application Server 2024-02-28 5.0 MEDIUM 9.8 CRITICAL
A vulnerability has been identified in SPPA-T3000 Application Server (All versions < Service Pack R8.2 SP2). The AdminService is available without authentication on the Application Server. An attacker can use methods exposed via this interface to receive password hashes of other users and to change user passwords. Please note that an attacker needs to have access to the Application Highway in order to exploit this vulnerability. At the time of advisory publication no public exploitation of this security vulnerability was known.
CVE-2019-11745 6 Canonical, Debian, Mozilla and 3 more 23 Ubuntu Linux, Debian Linux, Firefox and 20 more 2024-02-28 6.8 MEDIUM 8.8 HIGH
When encrypting with a block cipher, if a call to NSC_EncryptUpdate was made with data smaller than the block size, a small out of bounds write could occur. This could have caused heap corruption and a potentially exploitable crash. This vulnerability affects Thunderbird < 68.3, Firefox ESR < 68.3, and Firefox < 71.
CVE-2019-19290 1 Siemens 2 Sinvr 3 Central Control Server, Sinvr 3 Video Server 2024-02-28 4.0 MEDIUM 6.5 MEDIUM
A vulnerability has been identified in Control Center Server (CCS) (All versions < V1.5.0). The DOWNLOADS section in the web interface of the Control Center Server (CCS) contains a path traversal vulnerability that could allow an authenticated remote attacker to access and download arbitrary files from the server where CCS is installed.
CVE-2019-18324 1 Siemens 1 Sppa-t3000 Ms3000 Migration Server 2024-02-28 7.5 HIGH 9.8 CRITICAL
A vulnerability has been identified in SPPA-T3000 MS3000 Migration Server (All versions). An attacker with network access to the MS3000 Server can cause a Denial-of-Service condition and potentially gain remote code execution by sending specifically crafted packets to 5010/tcp. This vulnerability is independent from CVE-2019-18323, CVE-2019-18325, CVE-2019-18326, CVE-2019-18327, CVE-2019-18328, CVE-2019-18329, and CVE-2019-18330. Please note that an attacker needs to have network access to the MS3000 in order to exploit this vulnerability. At the time of advisory publication no public exploitation of this security vulnerability was known.
CVE-2019-13926 1 Siemens 8 Scalance S602, Scalance S602 Firmware, Scalance S612 and 5 more 2024-02-28 7.8 HIGH 7.5 HIGH
A vulnerability has been identified in SCALANCE S602 (All versions >= V3.0 and < V4.1), SCALANCE S612 (All versions >= V3.0 and < V4.1), SCALANCE S623 (All versions >= V3.0 and < V4.1), SCALANCE S627-2M (All versions >= V3.0 and < V4.1). Specially crafted packets sent to port 443/tcp of affected devices could cause a Denial-of-Service condition of the web server. A cold reboot is required to restore the functionality of the device.
CVE-2018-16417 2 Arubanetworks, Siemens 3 Instant, W1750d, W1750d Firmware 2024-02-28 5.0 MEDIUM 7.5 HIGH
Aruba Instant 4.x prior to 6.4.4.8-4.2.4.12, 6.5.x prior to 6.5.4.11, 8.3.x prior to 8.3.0.6, and 8.4.x prior to 8.4.0.1 allows Command injection.
CVE-2019-18312 1 Siemens 1 Sppa-t3000 Ms3000 Migration Server 2024-02-28 5.0 MEDIUM 5.3 MEDIUM
A vulnerability has been identified in SPPA-T3000 MS3000 Migration Server (All versions). An attacker with network access to the MS3000 Server could be able to enumerate running RPC services. Please note that an attacker needs to have network access to the MS3000 in order to exploit this vulnerability. At the time of advisory publication no public exploitation of this security vulnerability was known.
CVE-2019-18311 1 Siemens 1 Sppa-t3000 Ms3000 Migration Server 2024-02-28 5.0 MEDIUM 7.5 HIGH
A vulnerability has been identified in SPPA-T3000 MS3000 Migration Server (All versions). An attacker with network access to the MS3000 Server could trigger a Denial-of-Service condition by sending specifically crafted packets to port 7061/tcp. This vulnerability is independent from CVE-2019-18310. Please note that an attacker needs to have network access to the MS3000 in order to exploit this vulnerability. At the time of advisory publication no public exploitation of this security vulnerability was known.
CVE-2019-18317 1 Siemens 1 Sppa-t3000 Application Server 2024-02-28 5.0 MEDIUM 7.5 HIGH
A vulnerability has been identified in SPPA-T3000 Application Server (All versions < Service Pack R8.2 SP2). An attacker with network access to the Application Server could cause a Denial-of-Service condition by sending specifically crafted objects via RMI. This vulnerability is independent from CVE-2019-18318 and CVE-2019-18319. Please note that an attacker needs to have network access to the Application Server in order to exploit this vulnerability. At the time of advisory publication no public exploitation of this security vulnerability was known.
CVE-2019-18299 1 Siemens 1 Sppa-t3000 Ms3000 Migration Server 2024-02-28 5.0 MEDIUM 7.5 HIGH
A vulnerability has been identified in SPPA-T3000 MS3000 Migration Server (All versions). An attacker with network access to the MS3000 Server can trigger a Denial-of-Service condition by sending specifically crafted packets to port 5010/tcp. This vulnerability is independent from CVE-2019-18290, CVE-2019-18291, CVE-2019-18292, CVE-2019-18294, CVE-2019-18298, CVE-2019-18300, CVE-2019-18301, CVE-2019-18302, CVE-2019-18303, CVE-2019-18304, CVE-2019-18305, CVE-2019-18306, and CVE-2019-18307. Please note that an attacker needs to have network access to the MS3000 in order to exploit this vulnerability. At the time of advisory publication no public exploitation of this security vulnerability was known.
CVE-2019-19296 1 Siemens 2 Sinvr 3 Central Control Server, Sinvr 3 Video Server 2024-02-28 4.9 MEDIUM 6.8 MEDIUM
A vulnerability has been identified in SiNVR/SiVMS Video Server (All versions < V5.0.0). The two FTP services (default ports 21/tcp and 5411/tcp) of the SiVMS/SiNVR Video Server contain a path traversal vulnerability that could allow an authenticated remote attacker to access and download arbitrary files from the server, if the FTP services are enabled.
CVE-2019-19956 7 Canonical, Debian, Fedoraproject and 4 more 12 Ubuntu Linux, Debian Linux, Fedora and 9 more 2024-02-28 5.0 MEDIUM 7.5 HIGH
xmlParseBalancedChunkMemoryRecover in parser.c in libxml2 before 2.9.10 has a memory leak related to newDoc->oldNs.
CVE-2019-13931 1 Siemens 1 Xhq 2024-02-28 3.5 LOW 5.4 MEDIUM
A vulnerability has been identified in XHQ (All versions < V6.0.0.2). The web interface could allow for an an attacker to craft the input in a form that is not expected, causing the application to behave in unexpected ways for legitimate users. Successful exploitation requires for an attacker to be authenticated to the web interface. A successful attack could cause the application to have unexpected behavior. This could allow the attacker to modify contents of the web application. At the time of advisory publication no public exploitation of this security vulnerability was known.