CVE Vendors Products Updated CVSS v2 CVSS v3
CVE-2018-10601 1 Philips 36 Avalon Fetal\/maternal Monitors Fm20, Avalon Fetal\/maternal Monitors Fm20 Firmware, Avalon Fetal\/maternal Monitors Fm30 and 33 more 2024-02-28 5.4 MEDIUM 8.2 HIGH
IntelliVue Patient Monitors MP Series (including MP2/X2/MP30/MP50/MP70/NP90/MX700/800) Rev B-M, IntelliVue Patient Monitors MX (MX400-550) Rev J-M and (X3/MX100 for Rev M only), and Avalon Fetal/Maternal Monitors FM20/FM30/FM40/FM50 with software Revisions F.0, G.0 and J.3 have a vulnerability that exposes an "echo" service, in which an attacker-sent buffer to an attacker-chosen device address within the same subnet is copied to the stack with no boundary checks, hence resulting in stack overflow.
CVE-2017-14797 1 Philips 2 Hue Bridge Bsb002, Hue Bridge Bsb002 Firmware 2024-02-28 7.9 HIGH 7.5 HIGH
Lack of Transport Encryption in the public API in Philips Hue Bridge BSB002 SW 1707040932 allows remote attackers to read API keys (and consequently bypass the pushlink protection mechanism, and obtain complete control of the connected accessories) by leveraging the ability to sniff HTTP traffic on the local intranet network.
CVE-2017-14111 1 Philips 2 Intellispace Cardiovascular, Xcelera 2024-02-28 4.0 MEDIUM 7.2 HIGH
The workstation logging function in Philips IntelliSpace Cardiovascular (ISCV) 2.3.0 and earlier and Xcelera R4.1L1 and earlier records domain authentication credentials, which if accessed allows an attacker to use credentials to access the application, or other user entitlements.
CVE-2015-2884 1 Philips 1 In.sight B120\\37 2024-02-28 5.0 MEDIUM 7.5 HIGH
Philips In.Sight B120/37 allows remote attackers to obtain sensitive information via a direct request, related to yoics.net URLs, stream.m3u8 URIs, and cam_service_enable.cgi.
CVE-2015-2883 1 Philips 1 In.sight B120\\37 2024-02-28 3.5 LOW 5.4 MEDIUM
Philips In.Sight B120/37 has XSS, related to the Weaved cloud web service, as demonstrated by the name parameter to deviceSettings.php or shareDevice.php.
CVE-2015-2882 1 Philips 1 In.sight B120\\37 2024-02-28 10.0 HIGH 9.8 CRITICAL
Philips In.Sight B120/37 has a password of b120root for the backdoor root account, a password of /ADMIN/ for the backdoor admin account, a password of merlin for the backdoor mg3500 account, a password of M100-4674448 for the backdoor user account, and a password of M100-4674448 for the backdoor admin account.
CVE-2013-2808 1 Philips 4 Xper Flex Cardio, Xper Information Management Physiomonitoring 5, Xper Information Management Vascular Monitoring 5 and 1 more 2024-02-28 9.3 HIGH N/A
Heap-based buffer overflow in Xper in Philips Xper Information Management Physiomonitoring 5 components, Xper Information Management Vascular Monitoring 5 components, and Xper Information Management servers and workstations for Flex Cardio products before XperConnect 1.5.4.053 SP2 allows remote attackers to execute arbitrary code via a crafted HTTP request to the Connect broker on TCP port 6000.