Vulnerabilities (CVE)

Filtered by vendor Philips Subscribe
Total 107 CVE
CVE Vendors Products Updated CVSS v2 CVSS v3
CVE-2021-27497 1 Philips 4 Myvue, Speech, Vue Motion and 1 more 2024-11-21 7.5 HIGH 6.5 MEDIUM
Philips Vue PACS versions 12.2.x.x and prior does not use or incorrectly uses a protection mechanism that provides sufficient defense against directed attacks against the product.
CVE-2021-27493 1 Philips 4 Myvue, Speech, Vue Motion and 1 more 2024-11-21 6.4 MEDIUM 6.1 MEDIUM
Philips Vue PACS versions 12.2.x.x and prior does not ensure or incorrectly ensures structured messages or data are well formed and that certain security properties are met before being read from an upstream component or sent to a downstream component.
CVE-2021-26262 1 Philips 4 Mri 1.5t, Mri 1.5t Firmware, Mri 3t and 1 more 2024-11-21 5.0 MEDIUM 6.2 MEDIUM
Philips MRI 1.5T and MRI 3T Version 5.x.x does not restrict or incorrectly restricts access to a resource from an unauthorized actor.
CVE-2021-26248 1 Philips 4 Mri 1.5t, Mri 1.5t Firmware, Mri 3t and 1 more 2024-11-21 2.1 LOW 6.2 MEDIUM
Philips MRI 1.5T and MRI 3T Version 5.x.x assigns an owner who is outside the intended control sphere to a resource.
CVE-2021-23173 1 Philips 1 Engage 2024-11-21 4.0 MEDIUM 2.6 LOW
The affected product is vulnerable to an improper access control, which may allow an authenticated user to gain unauthorized access to sensitive data.
CVE-2020-7360 1 Philips 1 Smartcontrol 2024-11-21 6.9 MEDIUM 7.4 HIGH
An Uncontrolled Search Path Element (CWE-427) vulnerability in SmartControl version 4.3.15 and versions released before April 15, 2020 may allow an authenticated user to escalate privileges by placing a specially crafted DLL file in the search path. This issue was fixed in version 1.0.7, which was released after April 15, 2020. (Note, the version numbering system changed significantly between version 4.3.15 and version 1.0.7.)
CVE-2020-6007 1 Philips 2 Hue Bridge V2, Hue Bridge V2 Firmware 2024-11-21 4.3 MEDIUM 7.9 HIGH
Philips Hue Bridge model 2.X prior to and including version 1935144020 contains a Heap-based Buffer Overflow when handling a long ZCL string during the commissioning phase, resulting in a remote code execution.
CVE-2020-27298 1 Philips 5 Coronary Tools, Dynamic Coronary Roadmap, Interventional Workspot and 2 more 2024-11-21 3.3 LOW 6.5 MEDIUM
Philips Interventional Workspot (Release 1.3.2, 1.4.0, 1.4.1, 1.4.3, 1.4.5), Coronary Tools/Dynamic Coronary Roadmap/Stentboost Live (Release 1.0), ViewForum (Release 6.3V1L10). The software constructs all or part of an OS command using externally influenced input from an upstream component but does not neutralize or incorrectly neutralizes special elements that could modify the intended OS command when sent to a downstream component.
CVE-2020-16247 1 Philips 1 Clinical Collaboration Platform 2024-11-21 3.6 LOW 7.1 HIGH
Philips Clinical Collaboration Platform, Versions 12.2.1 and prior. The product exposes a resource to the wrong control sphere, providing unintended actors with inappropriate access to the resource.
CVE-2020-16241 1 Philips 2 Suresigns Vs4, Suresigns Vs4 Firmware 2024-11-21 2.1 LOW 2.1 LOW
Philips SureSigns VS4, A.07.107 and prior. The software does not restrict or incorrectly restricts access to a resource from an unauthorized actor.
CVE-2020-16239 1 Philips 2 Suresigns Vs4, Suresigns Vs4 Firmware 2024-11-21 4.0 MEDIUM 4.9 MEDIUM
Philips SureSigns VS4, A.07.107 and prior. When an actor claims to have a given identity, the software does not prove or insufficiently proves the claim is correct.
CVE-2020-16237 1 Philips 2 Suresigns Vs4, Suresigns Vs4 Firmware 2024-11-21 2.1 LOW 2.1 LOW
Philips SureSigns VS4, A.07.107 and prior. The product receives input or data, but it does not validate or incorrectly validates that the input has the properties required to process the data safely and correctly.
CVE-2020-16228 1 Philips 24 Intellivue Mp2-mp90, Intellivue Mp2-mp90 Firmware, Intellivue Mx100 and 21 more 2024-11-21 5.2 MEDIUM 6.4 MEDIUM
In Patient Information Center iX (PICiX) Versions C.02 and C.03, PerformanceBridge Focal Point Version A.01, IntelliVue patient monitors MX100, MX400-MX550, MX750, MX850, and IntelliVue X3 Versions N and prior, the software does not check or incorrectly checks the revocation status of a certificate, which may cause it to use a compromised certificate.
CVE-2020-16224 1 Philips 1 Patient Information Center Ix 2024-11-21 3.3 LOW 6.5 MEDIUM
In Patient Information Center iX (PICiX) Versions C.02, C.03, the software parses a formatted message or structure but does not handle or incorrectly handles a length field that is inconsistent with the actual length of the associated data, causing the application on the surveillance station to restart.
CVE-2020-16222 1 Philips 2 Patient Information Center Ix, Performancebridge Focal Point 2024-11-21 5.8 MEDIUM 8.8 HIGH
In Patient Information Center iX (PICiX) Version B.02, C.02, C.03, and PerformanceBridge Focal Point Version A.01, when an actor claims to have a given identity, the software does not prove or insufficiently proves the claim is correct.
CVE-2020-16220 1 Philips 2 Patient Information Center Ix, Performancebridge Focal Point 2024-11-21 3.3 LOW 4.3 MEDIUM
In Patient Information Center iX (PICiX) Versions C.02, C.03, PerformanceBridge Focal Point Version A.01, the product receives input that is expected to be well-formed (i.e., to comply with a certain syntax) but it does not validate or incorrectly validates that the input complies with the syntax, causing the certificate enrollment service to crash. It does not impact monitoring but prevents new devices from enrolling.
CVE-2020-16218 1 Philips 1 Patient Information Center Ix 2024-11-21 2.7 LOW 3.5 LOW
In Patient Information Center iX (PICiX) Versions B.02, C.02, C.03, the software does not neutralize or incorrectly neutralizes user-controllable input before it is placed in output that is then used as a webpage and served to other users. Successful exploitation could lead to unauthorized access to patient data via a read-only web application.
CVE-2020-16216 1 Philips 24 Intellivue Mp2-mp90, Intellivue Mp2-mp90 Firmware, Intellivue Mx100 and 21 more 2024-11-21 6.1 MEDIUM 6.5 MEDIUM
In IntelliVue patient monitors MX100, MX400-550, MX600, MX700, MX750, MX800, MX850, MP2-MP90, and IntelliVue X2 and X3 Versions N and prior, the product receives input or data but does not validate or incorrectly validates that the input has the properties required to process the data safely and correctly, which can induce a denial-of-service condition through a system restart.
CVE-2020-16214 1 Philips 1 Patient Information Center Ix 2024-11-21 5.8 MEDIUM 5.0 MEDIUM
In Patient Information Center iX (PICiX) Versions B.02, C.02, C.03, the software saves user-provided information into a comma-separated value (CSV) file, but it does not neutralize or incorrectly neutralizes special elements that could be interpreted as a command when the file is opened by spreadsheet software.
CVE-2020-16212 1 Philips 1 Patient Information Center Ix 2024-11-21 4.6 MEDIUM 6.8 MEDIUM
In Patient Information Center iX (PICiX) Versions B.02, C.02, C.03, the product exposes a resource to the wrong control sphere, providing unintended actors with inappropriate access to the resource. The application on the surveillance station operates in kiosk mode, which is vulnerable to local breakouts that could allow an attacker with physical access to escape the restricted environment with limited privileges.