Filtered by vendor Ge
Subscribe
Total
128 CVE
CVE | Vendors | Products | Updated | CVSS v2 | CVSS v3 |
---|---|---|---|---|---|
CVE-2014-2355 | 1 Ge | 1 Intelligent Platforms Proficy Hmi\/scada Cimplicity | 2024-11-21 | 6.9 MEDIUM | N/A |
The (1) CimView and (2) CimEdit components in GE Proficy HMI/SCADA-CIMPLICITY 8.2 and earlier allow remote attackers to gain privileges via a crafted CIMPLICITY screen (aka .CIM) file. | |||||
CVE-2014-0751 | 1 Ge | 3 Intelligent Platforms Proficy Hmi\%2fscada Cimplicity, Intelligent Platforms Proficy Hmi\/scada Cimplicity, Intelligent Platforms Proficy Process Systems With Cimplicity | 2024-11-21 | 7.5 HIGH | N/A |
Directory traversal vulnerability in CimWebServer.exe (aka the WebView component) in GE Intelligent Platforms Proficy HMI/SCADA - CIMPLICITY before 8.2 SIM 24, and Proficy Process Systems with CIMPLICITY, allows remote attackers to execute arbitrary code via a crafted message to TCP port 10212, aka ZDI-CAN-1623. | |||||
CVE-2014-0750 | 1 Ge | 3 Intelligent Platforms Proficy Hmi\%2fscada Cimplicity, Intelligent Platforms Proficy Hmi\/scada Cimplicity, Intelligent Platforms Proficy Process Systems With Cimplicity | 2024-11-21 | 7.5 HIGH | N/A |
Directory traversal vulnerability in gefebt.exe in the WebView CimWeb components in GE Intelligent Platforms Proficy HMI/SCADA - CIMPLICITY through 8.2 SIM 24, and Proficy Process Systems with CIMPLICITY, allows remote attackers to execute arbitrary code via a crafted HTTP request, aka ZDI-CAN-1622. | |||||
CVE-2013-2823 | 2 Catapultsoftware, Ge | 4 Catapult Dnp3 I\/o Driver, Intelligent Platforms Proficy Dnp3 I\/o Driver, Intelligent Platforms Proficy Hmi\/scada Cimplicity and 1 more | 2024-11-21 | 4.7 MEDIUM | N/A |
The (1) Catapult DNP3 I/O driver before 7.2.0.60 and the (2) GE Intelligent Platforms Proficy DNP3 I/O driver before 7.20k, as used in DNPDrv.exe (aka the DNP master station server) in GE Intelligent Platforms Proficy HMI/SCADA - CIMPLICITY and iFIX, allow physically proximate attackers to cause a denial of service (infinite loop) via crafted input over a serial line. | |||||
CVE-2013-2811 | 2 Catapultsoftware, Ge | 4 Catapult Dnp3 I\/o Driver, Intelligent Platforms Proficy Dnp3 I\/o Driver, Intelligent Platforms Proficy Hmi\/scada Cimplicity and 1 more | 2024-11-21 | 7.1 HIGH | N/A |
The (1) Catapult DNP3 I/O driver before 7.2.0.60 and the (2) GE Intelligent Platforms Proficy DNP3 I/O driver before 7.20k, as used in DNPDrv.exe (aka the DNP master station server) in GE Intelligent Platforms Proficy HMI/SCADA - CIMPLICITY and iFIX, allow remote attackers to cause a denial of service (infinite loop) via a crafted DNP3 TCP packet. | |||||
CVE-2013-2785 | 1 Ge | 2 Intelligent Platforms Proficy Hmi\/scada Cimplicity, Intelligent Platforms Proficy Process Systems With Cimplicity | 2024-11-21 | 9.3 HIGH | N/A |
Multiple buffer overflows in CimWebServer.exe in the WebView component in GE Intelligent Platforms Proficy HMI/SCADA - CIMPLICITY before 8.0 SIM 27, 8.1 before SIM 25, and 8.2 before SIM 19, and Proficy Process Systems with CIMPLICITY, allow remote attackers to execute arbitrary code via crafted data in packets to TCP port 10212, aka ZDI-CAN-1621 and ZDI-CAN-1624. | |||||
CVE-2013-0654 | 1 Ge | 3 Intelligent Platforms Proficy Hmi\/scada Cimplicity, Intelligent Platforms Proficy Process Systems, Intelligent Platforms Proficy Process Systems With Cimplicity | 2024-11-21 | 9.3 HIGH | N/A |
CimWebServer in GE Intelligent Platforms Proficy HMI/SCADA - CIMPLICITY 4.01 through 8.0, and Proficy Process Systems with CIMPLICITY, allows remote attackers to execute arbitrary commands or cause a denial of service (daemon crash) via a crafted packet. | |||||
CVE-2013-0653 | 1 Ge | 3 Intelligent Platforms Proficy Hmi\/scada Cimplicity, Intelligent Platforms Proficy Process Systems, Intelligent Platforms Proficy Process Systems With Cimplicity | 2024-11-21 | 4.3 MEDIUM | N/A |
Directory traversal vulnerability in substitute.bcl in the WebView CimWeb subsystem in GE Intelligent Platforms Proficy HMI/SCADA - CIMPLICITY 4.01 through 8.0, and Proficy Process Systems with CIMPLICITY, allows remote attackers to read arbitrary files via a crafted packet. | |||||
CVE-2013-0652 | 1 Ge | 1 Intelligent Platforms Proficy Real-time Information Portal | 2024-11-21 | 5.0 MEDIUM | N/A |
GE Intelligent Platforms Proficy Real-Time Information Portal does not restrict access to methods of an unspecified Java class, which allows remote attackers to obtain a username listing via an RMI call. | |||||
CVE-2013-0651 | 1 Ge | 1 Intelligent Platforms Proficy Real-time Information Portal | 2024-11-21 | 5.0 MEDIUM | N/A |
The Portal installation process in GE Intelligent Platforms Proficy Real-Time Information Portal stores sensitive information under the web root with insufficient access control, which allows remote attackers to read configuration files, and discover data-source credentials, via a direct request. | |||||
CVE-2012-6663 | 1 Ge | 4 D200, D200 Firmware, D20me and 1 more | 2024-11-21 | 5.0 MEDIUM | 7.5 HIGH |
General Electric D20ME devices are not properly configured and reveal plaintext passwords. | |||||
CVE-2012-4689 | 1 Ge | 3 Intelligent Platforms Proficy Hmi\/scada Cimplicity, Intelligent Platforms Proficy Process Systems, Intelligent Platforms Proficy Process Systems With Cimplicity | 2024-11-21 | 4.3 MEDIUM | N/A |
Integer overflow in CimWebServer.exe in GE Intelligent Platforms Proficy HMI/SCADA - CIMPLICITY 4.01 through 8.0, and Proficy Process Systems with CIMPLICITY, allows remote attackers to cause a denial of service (daemon crash) via a malformed HTTP request. | |||||
CVE-2012-3026 | 1 Ge | 1 Intelligent Platforms Proficy Real-time Information Portal | 2024-11-21 | 10.0 HIGH | N/A |
rifsrvd.exe in the Remote Interface Service in GE Intelligent Platforms Proficy Real-Time Information Portal 2.6 through 3.5 SP1 allows remote attackers to cause a denial of service (memory corruption and service crash) or possibly execute arbitrary code via long input data, a different vulnerability than CVE-2012-3010 and CVE-2012-3021. | |||||
CVE-2012-3021 | 1 Ge | 1 Intelligent Platforms Proficy Real-time Information Portal | 2024-11-21 | 10.0 HIGH | N/A |
rifsrvd.exe in the Remote Interface Service in GE Intelligent Platforms Proficy Real-Time Information Portal 2.6 through 3.5 SP1 allows remote attackers to cause a denial of service (memory corruption and service crash) or possibly execute arbitrary code via long input data, a different vulnerability than CVE-2012-3010 and CVE-2012-3026. | |||||
CVE-2012-3010 | 1 Ge | 1 Intelligent Platforms Proficy Real-time Information Portal | 2024-11-21 | 10.0 HIGH | N/A |
rifsrvd.exe in the Remote Interface Service in GE Intelligent Platforms Proficy Real-Time Information Portal 2.6 through 3.5 SP1 allows remote attackers to cause a denial of service (memory corruption and service crash) or possibly execute arbitrary code via long input data, a different vulnerability than CVE-2012-3021 and CVE-2012-3026. | |||||
CVE-2012-2516 | 1 Ge | 5 Intelligent Platforms Proficy Batch Execution, Intelligent Platforms Proficy Historian, Intelligent Platforms Proficy Hmi\/scada Ifix and 2 more | 2024-11-21 | 9.3 HIGH | N/A |
An ActiveX control in KeyHelp.ocx in KeyWorks KeyHelp Module (aka the HTML Help component), as used in GE Intelligent Platforms Proficy Historian 3.1, 3.5, 4.0, and 4.5; Proficy HMI/SCADA iFIX 5.0 and 5.1; Proficy Pulse 1.0; Proficy Batch Execution 5.6; SI7 I/O Driver 7.20 through 7.42; and other products, allows remote attackers to execute arbitrary commands via crafted input, related to a "command injection vulnerability." | |||||
CVE-2012-2515 | 2 Emc, Ge | 7 Captiva Quickscan Pro, Documentum Applicationxtender Desktop, Intelligent Platforms Proficy Batch Execution and 4 more | 2024-11-21 | 9.3 HIGH | N/A |
Multiple stack-based buffer overflows in the KeyHelp.KeyCtrl.1 ActiveX control in KeyHelp.ocx 1.2.312 in KeyWorks KeyHelp Module (aka the HTML Help component), as used in EMC Documentum ApplicationXtender Desktop 5.4; EMC Captiva Quickscan Pro 4.6 SP1; GE Intelligent Platforms Proficy Historian 3.1, 3.5, 4.0, and 4.5; GE Intelligent Platforms Proficy HMI/SCADA iFIX 5.0 and 5.1; GE Intelligent Platforms Proficy Pulse 1.0; GE Intelligent Platforms Proficy Batch Execution 5.6; GE Intelligent Platforms SI7 I/O Driver 7.20 through 7.42; and other products, allow remote attackers to execute arbitrary code via a long string in the second argument to the (1) JumpMappedID or (2) JumpURL method. | |||||
CVE-2012-0232 | 1 Ge | 1 Intelligent Platforms Proficy Real-time Information Portal | 2024-11-21 | 6.4 MEDIUM | N/A |
Directory traversal vulnerability in rifsrvd.exe in the Remote Interface Service in GE Intelligent Platforms Proficy Real-Time Information Portal 2.6, 3.0, 3.0 SP1, and 3.5 allows remote attackers to modify the configuration via crafted strings. | |||||
CVE-2012-0231 | 1 Ge | 1 Intelligent Platforms Proficy Plant Applications | 2024-11-21 | 10.0 HIGH | N/A |
PRLicenseMgr.exe in the Proficy Server License Manager in GE Intelligent Platforms Proficy Plant Applications 5.0 and earlier allows remote attackers to cause a denial of service (memory corruption) or possibly execute arbitrary code via a crafted TCP session on port 12401. | |||||
CVE-2012-0230 | 1 Ge | 1 Intelligent Platforms Proficy Plant Applications | 2024-11-21 | 10.0 HIGH | N/A |
PRRDS.exe in the Proficy Remote Data Service in GE Intelligent Platforms Proficy Plant Applications 5.0 and earlier allows remote attackers to cause a denial of service (memory corruption) or possibly execute arbitrary code via a crafted TCP session on port 12299. |