Filtered by vendor Mitsubishielectric
Subscribe
Total
158 CVE
CVE | Vendors | Products | Updated | CVSS v2 | CVSS v3 |
---|---|---|---|---|---|
CVE-2020-14496 | 1 Mitsubishielectric | 29 Cpu Module Logging Configuration Tool, Cw Configurator, Data Transfer and 26 more | 2024-02-28 | 7.5 HIGH | 9.8 CRITICAL |
Successful exploitation of this vulnerability for multiple Mitsubishi Electric Factory Automation Engineering Software Products of various versions could allow an attacker to escalate privilege and execute malicious programs, which could cause a denial-of-service condition, and allow information to be disclosed, tampered with, and/or destroyed. | |||||
CVE-2022-25160 | 1 Mitsubishielectric | 32 Fx5uc, Fx5uc-32mr\/ds-ts, Fx5uc-32mr\/ds-ts Firmware and 29 more | 2024-02-28 | 4.3 MEDIUM | 5.9 MEDIUM |
Cleartext Storage of Sensitive Information vulnerability in Mitsubishi Electric MELSEC iQ-F series FX5U(C) CPU all versions, Mitsubishi Electric MELSEC iQ-F series FX5UJ CPU all versions, Mitsubishi Electric MELSEC iQ-R series R00/01/02CPU all versions, Mitsubishi Electric MELSEC iQ-R series R04/08/16/32/120(EN)CPU all versions, Mitsubishi Electric MELSEC iQ-R series R08/16/32/120SFCPU all versions, Mitsubishi Electric MELSEC iQ-R series R08/16/32/120PCPU all versions, Mitsubishi Electric MELSEC iQ-R series R08/16/32/120PSFCPU all versions, Mitsubishi Electric MELSEC iQ-R series R16/32/64MTCPU all versions, Mitsubishi Electric MELSEC iQ-R series RJ71C24(-R2/R4) all versions, Mitsubishi Electric MELSEC iQ-R series RJ71EN71 all versions, Mitsubishi Electric MELSEC iQ-R series RJ72GF15-T2 all versions, Mitsubishi Electric MELSEC Q series Q03/04/06/13/26UDVCPU all versions, Mitsubishi Electric MELSEC Q series Q04/06/13/26UDPVCPU all versions, Mitsubishi Electric MELSEC Q series QJ71C24N(-R2/R4) all versions and Mitsubishi Electric MELSEC Q series QJ71E71-100 all versions allows a remote unauthenticated attacker to disclose a file in a legitimate user's product by using previously eavesdropped cleartext information and to counterfeit a legitimate user’s system. | |||||
CVE-2022-25159 | 1 Mitsubishielectric | 32 Fx5uc, Fx5uc-32mr\/ds-ts, Fx5uc-32mr\/ds-ts Firmware and 29 more | 2024-02-28 | 6.8 MEDIUM | 8.1 HIGH |
Authentication Bypass by Capture-replay vulnerability in Mitsubishi Electric MELSEC iQ-F series FX5U(C) CPU all versions, Mitsubishi Electric MELSEC iQ-F series FX5UJ CPU all versions, Mitsubishi Electric MELSEC iQ-R series R00/01/02CPU all versions, Mitsubishi Electric MELSEC iQ-R series R04/08/16/32/120(EN)CPU all versions, Mitsubishi Electric MELSEC iQ-R series R08/16/32/120SFCPU all versions, Mitsubishi Electric MELSEC iQ-R series R08/16/32/120PCPU all versions, Mitsubishi Electric MELSEC iQ-R series R08/16/32/120PSFCPU all versions, Mitsubishi Electric MELSEC iQ-R series R16/32/64MTCPU all versions, Mitsubishi Electric MELSEC iQ-R series RJ71C24(-R2/R4) all versions, Mitsubishi Electric MELSEC iQ-R series RJ71EN71 all versions, Mitsubishi Electric MELSEC iQ-R series RJ72GF15-T2 all versions, Mitsubishi Electric MELSEC Q series Q03/04/06/13/26UDVCPU all versions, Mitsubishi Electric MELSEC Q series Q04/06/13/26UDPVCPU all versions, Mitsubishi Electric MELSEC Q series QJ71C24N(-R2/R4) all versions and Mitsubishi Electric MELSEC Q series QJ71E71-100 all versions allows a remote unauthenticated attacker to login to the product by replay attack. | |||||
CVE-2022-25156 | 1 Mitsubishielectric | 32 Fx5uc, Fx5uc-32mr\/ds-ts, Fx5uc-32mr\/ds-ts Firmware and 29 more | 2024-02-28 | 6.8 MEDIUM | 8.1 HIGH |
Use of Weak Hash vulnerability in Mitsubishi Electric MELSEC iQ-F series FX5U(C) CPU all versions, Mitsubishi Electric MELSEC iQ-F series FX5UJ CPU all versions, Mitsubishi Electric MELSEC iQ-R series R00/01/02CPU all versions, Mitsubishi Electric MELSEC iQ-R series R04/08/16/32/120(EN)CPU all versions, Mitsubishi Electric MELSEC iQ-R series R08/16/32/120SFCPU all versions, Mitsubishi Electric MELSEC iQ-R series R08/16/32/120PCPU all versions, Mitsubishi Electric MELSEC iQ-R series R08/16/32/120PSFCPU all versions, Mitsubishi Electric MELSEC iQ-R series RJ71C24(-R2/R4) all versions, Mitsubishi Electric MELSEC iQ-R series RJ71EN71 all versions, Mitsubishi Electric MELSEC iQ-R series RJ72GF15-T2 all versions, Mitsubishi Electric MELSEC Q series Q03UDECPU all versions, Mitsubishi Electric MELSEC Q series Q04/06/10/13/20/26/50/100UDEHCPU all versions, Mitsubishi Electric MELSEC Q series Q03/04/06/13/26UDVCPU all versions, Mitsubishi Electric MELSEC Q series Q04/06/13/26UDPVCPU all versions, Mitsubishi Electric MELSEC Q series QJ71C24N(-R2/R4) all versions, Mitsubishi Electric MELSEC Q series QJ71E71-100 all versions, Mitsubishi Electric MELSEC Q series QJ72BR15 all versions, Mitsubishi Electric MELSEC Q series QJ72LP25(-25/G/GE) all versions, Mitsubishi Electric MELSEC L series L02/06/26CPU(-P) all versions, Mitsubishi Electric MELSEC L series L26CPU-(P)BT all versions, Mitsubishi Electric MELSEC L series LJ71C24(-R2) all versions, Mitsubishi Electric MELSEC L series LJ71E71-100 all versions and Mitsubishi Electric MELSEC L series LJ72GF15-T2 all versions allows a remote unauthenticated attacker to login to the product by using a password reversed from a previously eavesdropped password hash. | |||||
CVE-2021-20606 | 1 Mitsubishielectric | 3 Ezsocket, Gx Works2, Melsoft Navigator | 2024-02-28 | 4.3 MEDIUM | 5.5 MEDIUM |
Out-of-bounds Read vulnerability in Mitsubishi Electric GX Works2 versions 1.606G and prior, Mitsubishi Electric MELSOFT Navigator versions 2.84N and prior and Mitsubishi Electric EZSocket versions 5.4 and prior allows an attacker to cause a DoS condition in the software by getting a user to open malicious project file specially crafted by an attacker. | |||||
CVE-2021-20613 | 1 Mitsubishielectric | 6 Fx3u-enet, Fx3u-enet-l, Fx3u-enet-l Firmware and 3 more | 2024-02-28 | 7.8 HIGH | 7.5 HIGH |
Improper initialization vulnerability in MELSEC-F series FX3U-ENET Firmware version 1.16 and prior, FX3U-ENET-L Firmware version 1.16 and prior and FX3U-ENET-P502 Firmware version 1.16 and prior allows a remote unauthenticated attacker to cause a denial-of-service (DoS) condition in communication function of the product by sending specially crafted packets. Control by MELSEC-F series PLC is not affected by this vulnerability, but system reset is required for recovery. | |||||
CVE-2021-20601 | 1 Mitsubishielectric | 99 Got2000 Gt2103-pmbd, Got2000 Gt2103-pmbd Firmware, Got2000 Gt2103-pmbds and 96 more | 2024-02-28 | 7.8 HIGH | 7.5 HIGH |
Improper input validation vulnerability in GOT2000 series GT27 model all versions, GOT2000 series GT25 model all versions, GOT2000 series GT23 model all versions, GOT2000 series GT21 model all versions, GOT SIMPLE series GS21 model all versions, and GT SoftGOT2000 all versions allows an remote unauthenticated attacker to write a value that exceeds the configured input range limit by sending a malicious packet to rewrite the device value. As a result, the system operation may be affected, such as malfunction. | |||||
CVE-2022-23130 | 2 Iconics, Mitsubishielectric | 3 Genesis64, Hyper Historian, Mc Works64 | 2024-02-28 | 4.3 MEDIUM | 5.5 MEDIUM |
Buffer Over-read vulnerability in Mitsubishi Electric MC Works64 versions 4.00A (10.95.201.23) to 4.04E (10.95.210.01), ICONICS GENESIS64 versions 10.97 and prior and ICONICS Hyper Historian versions 10.97 and prior allows an attacker to cause a DoS condition in the database server by getting a legitimate user to import a configuration file containing specially crafted stored procedures into GENESIS64 or MC Works64 and execute commands against the database from GENESIS64 or MC Works64. | |||||
CVE-2022-23127 | 2 Iconics, Mitsubishielectric | 2 Mobilehmi, Mc Works64 | 2024-02-28 | 4.3 MEDIUM | 6.1 MEDIUM |
Cross-site Scripting vulnerability in Mitsubishi Electric MC Works64 versions 4.04E (10.95.210.01) and prior and ICONICS MobileHMI versions 10.96.2 and prior allows a remote unauthenticated attacker to gain authentication information of an MC Works64 or MobileHMI and perform any operation using the acquired authentication information, by injecting a malicious script in the URL of a monitoring screen delivered from the MC Works64 server or MobileHMI server to an application for mobile devices and leading a legitimate user to access this URL. | |||||
CVE-2022-23129 | 2 Iconics, Mitsubishielectric | 2 Genesis64, Mc Works64 | 2024-02-28 | 2.1 LOW | 5.5 MEDIUM |
Plaintext Storage of a Password vulnerability in Mitsubishi Electric MC Works64 versions 4.04E (10.95.210.01) and prior and ICONICS GENESIS64 versions 10.90 to 10.97 allows a local authenticated attacker to gain authentication information and to access the database illegally. This is because when configuration information of GridWorX, a database linkage function of GENESIS64 and MC Works64, is exported to a CSV file, the authentication information is saved in plaintext, and an attacker who can access this CSV file can gain the authentication information. | |||||
CVE-2021-20600 | 1 Mitsubishielectric | 2 R12ccpu-v, R12ccpu-v Firmware | 2024-02-28 | 7.1 HIGH | 5.9 MEDIUM |
Uncontrolled resource consumption in Mitsubishi Electric MELSEC iQ-R series C Controller Module R12CCPU-V Firmware Versions "16" and prior allows a remote unauthenticated attacker to cause a denial-of-service (DoS) condition by sending a large number of packets in a short time while the module starting up. System reset is required for recovery. | |||||
CVE-2021-20607 | 1 Mitsubishielectric | 3 Ezsocket, Gx Works2, Melsoft Navigator | 2024-02-28 | 4.3 MEDIUM | 5.5 MEDIUM |
Integer Underflow vulnerability in Mitsubishi Electric GX Works2 versions 1.606G and prior, Mitsubishi Electric MELSOFT Navigator versions 2.84N and prior and Mitsubishi Electric EZSocket versions 5.4 and prior allows an attacker to cause a DoS condition in the software by getting a user to open malicious project file specially crafted by an attacker. | |||||
CVE-2021-20612 | 1 Mitsubishielectric | 6 Fx3u-enet, Fx3u-enet-l, Fx3u-enet-l Firmware and 3 more | 2024-02-28 | 7.8 HIGH | 7.5 HIGH |
Lack of administrator control over security vulnerability in MELSEC-F series FX3U-ENET Firmware version 1.14 and prior, FX3U-ENET-L Firmware version 1.14 and prior and FX3U-ENET-P502 Firmware version 1.14 and prior allows a remote unauthenticated attacker to cause a denial-of-service (DoS) condition in communication function of the product or other unspecified effects by sending specially crafted packets to an unnecessary opening of TCP port. Control by MELSEC-F series PLC is not affected by this vulnerability, but system reset is required for recovery. | |||||
CVE-2022-23128 | 2 Iconics, Mitsubishielectric | 5 Analytix, Genesis64, Hyper Historian and 2 more | 2024-02-28 | 7.5 HIGH | 9.8 CRITICAL |
Incomplete List of Disallowed Inputs vulnerability in Mitsubishi Electric MC Works64 versions 4.00A (10.95.201.23) to 4.04E (10.95.210.01), ICONICS GENESIS64 versions 10.95.3 to 10.97, ICONICS Hyper Historian versions 10.95.3 to 10.97, ICONICS AnalytiX versions 10.95.3 to 10.97 and ICONICS MobileHMI versions 10.95.3 to 10.97 allows a remote unauthenticated attacker to bypass the authentication of MC Works64, GENESIS64, Hyper Historian, AnalytiX and MobileHMI, and gain unauthorized access to the products, by sending specially crafted WebSocket packets to FrameWorX server, one of the functions of the products. | |||||
CVE-2021-20608 | 1 Mitsubishielectric | 1 Gx Works2 | 2024-02-28 | 5.0 MEDIUM | 7.5 HIGH |
Improper Handling of Length Parameter Inconsistency vulnerability in Mitsubishi Electric GX Works2 versions 1.606G and prior allows a remote unauthenticated attacker to cause a DoS condition in GX Works2 by getting GX Works2 to read a tampered program file from a Mitsubishi Electric PLC by sending malicious crafted packets to tamper with the program file. | |||||
CVE-2021-27040 | 3 Autodesk, Iconics, Mitsubishielectric | 13 Advance Steel, Autocad, Autocad Architecture and 10 more | 2024-02-28 | 4.3 MEDIUM | 3.3 LOW |
A maliciously crafted DWG file can be forced to read beyond allocated boundaries when parsing the DWG file. This vulnerability can be exploited to execute arbitrary code. | |||||
CVE-2021-27041 | 3 Autodesk, Iconics, Mitsubishielectric | 13 Advance Steel, Autocad, Autocad Architecture and 10 more | 2024-02-28 | 6.8 MEDIUM | 7.8 HIGH |
A maliciously crafted DWG file can be used to write beyond the allocated buffer while parsing DWG files. This vulnerability can be exploited to execute arbitrary code | |||||
CVE-2021-20598 | 1 Mitsubishielectric | 16 R08psfcpu, R08psfcpu Firmware, R08sfcpu and 13 more | 2024-02-28 | 5.0 MEDIUM | 5.3 MEDIUM |
Overly Restrictive Account Lockout Mechanism vulnerability in Mitsubishi Electric MELSEC iQ-R series CPU modules (R08/16/32/120SFCPU all versions, R08/16/32/120PSFCPU all versions) allows a remote unauthenticated attacker to lockout a legitimate user by continuously trying login with incorrect password. | |||||
CVE-2021-20596 | 1 Mitsubishielectric | 3 Fx3u-enet-l Firmware, Fx3u-enet-p502 Firmware, Fx3u-enet Firmware | 2024-02-28 | 5.0 MEDIUM | 7.5 HIGH |
NULL Pointer Dereference in MELSEC-F Series FX3U-ENET firmware version 1.14 and prior, FX3U-ENET-L firmware version 1.14 and prior and FX3U-ENET-P502 firmware version 1.14 and prior allows a remote unauthenticated attacker to cause a DoS condition in communication by sending specially crafted packets. Control by MELSEC-F series PLC is not affected and system reset is required for recovery. | |||||
CVE-2021-20591 | 1 Mitsubishielectric | 40 R00cpu, R00cpu Firmware, R01cpu and 37 more | 2024-02-28 | 7.8 HIGH | 7.5 HIGH |
Uncontrolled Resource Consumption vulnerability in Mitsubishi Electric MELSEC iQ-R series CPU modules (R00/01/02CPU all versions, R04/08/16/32/120(EN)CPU all versions, R08/16/32/120SFCPU all versions, R08/16/32/120PCPU all versions, R08/16/32/120PSFCPU all versions) allows a remote unauthenticated attacker to prevent legitimate clients from connecting to the MELSOFT transmission port (TCP/IP) by not closing a connection properly, which may lead to a denial of service (DoS) condition. |