CVE-2022-25160

Cleartext Storage of Sensitive Information vulnerability in Mitsubishi Electric MELSEC iQ-F series FX5U(C) CPU all versions, Mitsubishi Electric MELSEC iQ-F series FX5UJ CPU all versions, Mitsubishi Electric MELSEC iQ-R series R00/01/02CPU all versions, Mitsubishi Electric MELSEC iQ-R series R04/08/16/32/120(EN)CPU all versions, Mitsubishi Electric MELSEC iQ-R series R08/16/32/120SFCPU all versions, Mitsubishi Electric MELSEC iQ-R series R08/16/32/120PCPU all versions, Mitsubishi Electric MELSEC iQ-R series R08/16/32/120PSFCPU all versions, Mitsubishi Electric MELSEC iQ-R series R16/32/64MTCPU all versions, Mitsubishi Electric MELSEC iQ-R series RJ71C24(-R2/R4) all versions, Mitsubishi Electric MELSEC iQ-R series RJ71EN71 all versions, Mitsubishi Electric MELSEC iQ-R series RJ72GF15-T2 all versions, Mitsubishi Electric MELSEC Q series Q03/04/06/13/26UDVCPU all versions, Mitsubishi Electric MELSEC Q series Q04/06/13/26UDPVCPU all versions, Mitsubishi Electric MELSEC Q series QJ71C24N(-R2/R4) all versions and Mitsubishi Electric MELSEC Q series QJ71E71-100 all versions allows a remote unauthenticated attacker to disclose a file in a legitimate user's product by using previously eavesdropped cleartext information and to counterfeit a legitimate user’s system.
Configurations

Configuration 1 (hide)

AND
cpe:2.3:o:mitsubishielectric:fx5uc_firmware:-:*:*:*:*:*:*:*
cpe:2.3:h:mitsubishielectric:fx5uc:-:*:*:*:*:*:*:*

Configuration 2 (hide)

AND
cpe:2.3:o:mitsubishielectric:fx5uc-32mr\/ds-ts_firmware:-:*:*:*:*:*:*:*
cpe:2.3:h:mitsubishielectric:fx5uc-32mr\/ds-ts:-:*:*:*:*:*:*:*

Configuration 3 (hide)

AND
cpe:2.3:o:mitsubishielectric:fx5uc-32mt\/d_firmware:-:*:*:*:*:*:*:*
cpe:2.3:h:mitsubishielectric:fx5uc-32mt\/d:-:*:*:*:*:*:*:*

Configuration 4 (hide)

AND
cpe:2.3:o:mitsubishielectric:fx5uc-32mt\/dss_firmware:-:*:*:*:*:*:*:*
cpe:2.3:h:mitsubishielectric:fx5uc-32mt\/dss:-:*:*:*:*:*:*:*

Configuration 5 (hide)

AND
cpe:2.3:o:mitsubishielectric:fx5uj-24mr\/es_firmware:-:*:*:*:*:*:*:*
cpe:2.3:h:mitsubishielectric:fx5uj-24mr\/es:-:*:*:*:*:*:*:*

Configuration 6 (hide)

AND
cpe:2.3:o:mitsubishielectric:fx5uj-24mt\/es_firmware:-:*:*:*:*:*:*:*
cpe:2.3:h:mitsubishielectric:fx5uj-24mt\/es:-:*:*:*:*:*:*:*

Configuration 7 (hide)

AND
cpe:2.3:o:mitsubishielectric:fx5uj-24mt\/ess_firmware:-:*:*:*:*:*:*:*
cpe:2.3:h:mitsubishielectric:fx5uj-24mt\/ess:-:*:*:*:*:*:*:*

Configuration 8 (hide)

AND
cpe:2.3:o:mitsubishielectric:fx5uj-40mr\/es_firmware:-:*:*:*:*:*:*:*
cpe:2.3:h:mitsubishielectric:fx5uj-40mr\/es:-:*:*:*:*:*:*:*

Configuration 9 (hide)

AND
cpe:2.3:o:mitsubishielectric:fx5uj-40mt\/es_firmware:-:*:*:*:*:*:*:*
cpe:2.3:h:mitsubishielectric:fx5uj-40mt\/es:-:*:*:*:*:*:*:*

Configuration 10 (hide)

AND
cpe:2.3:o:mitsubishielectric:fx5uj-40mt\/ess_firmware:-:*:*:*:*:*:*:*
cpe:2.3:h:mitsubishielectric:fx5uj-40mt\/ess:-:*:*:*:*:*:*:*

Configuration 11 (hide)

AND
cpe:2.3:o:mitsubishielectric:fx5uj-60mr\/es_firmware:-:*:*:*:*:*:*:*
cpe:2.3:h:mitsubishielectric:fx5uj-60mr\/es:-:*:*:*:*:*:*:*

Configuration 12 (hide)

AND
cpe:2.3:o:mitsubishielectric:fx5uj-60mt\/es_firmware:-:*:*:*:*:*:*:*
cpe:2.3:h:mitsubishielectric:fx5uj-60mt\/es:-:*:*:*:*:*:*:*

Configuration 13 (hide)

AND
cpe:2.3:o:mitsubishielectric:fx5uj-60mt\/ess_firmware:-:*:*:*:*:*:*:*
cpe:2.3:h:mitsubishielectric:fx5uj-60mt\/ess:-:*:*:*:*:*:*:*

Configuration 14 (hide)

AND
cpe:2.3:o:mitsubishielectric:fx5uc-32mt\/dss-ts_firmware:-:*:*:*:*:*:*:*
cpe:2.3:h:mitsubishielectric:fx5uc-32mt\/dss-ts:-:*:*:*:*:*:*:*

Configuration 15 (hide)

AND
cpe:2.3:o:mitsubishielectric:fx5uc-32mt\/ds-ts_firmware:-:*:*:*:*:*:*:*
cpe:2.3:h:mitsubishielectric:fx5uc-32mt\/ds-ts:-:*:*:*:*:*:*:*

Configuration 16 (hide)

AND
cpe:2.3:o:mitsubishielectric:fx5uj_firmware:-:*:*:*:*:*:*:*
cpe:2.3:h:mitsubishielectric:fx5uj:-:*:*:*:*:*:*:*

History

No history.

Information

Published : 2022-04-01 23:15

Updated : 2024-02-28 19:09


NVD link : CVE-2022-25160

Mitre link : CVE-2022-25160

CVE.ORG link : CVE-2022-25160


JSON object : View

Products Affected

mitsubishielectric

  • fx5uj-60mt\/ess
  • fx5uc-32mt\/dss-ts_firmware
  • fx5uc-32mt\/dss
  • fx5uj-40mr\/es_firmware
  • fx5uj-24mr\/es_firmware
  • fx5uc_firmware
  • fx5uc-32mt\/ds-ts
  • fx5uc
  • fx5uc-32mt\/dss-ts
  • fx5uj
  • fx5uj-60mr\/es
  • fx5uj-24mt\/ess
  • fx5uj-24mt\/ess_firmware
  • fx5uj-40mt\/ess
  • fx5uc-32mt\/dss_firmware
  • fx5uj_firmware
  • fx5uj-24mr\/es
  • fx5uj-40mt\/es
  • fx5uj-24mt\/es
  • fx5uj-60mt\/es_firmware
  • fx5uj-60mt\/ess_firmware
  • fx5uc-32mr\/ds-ts_firmware
  • fx5uj-24mt\/es_firmware
  • fx5uj-40mt\/ess_firmware
  • fx5uj-40mr\/es
  • fx5uc-32mt\/d
  • fx5uc-32mr\/ds-ts
  • fx5uc-32mt\/ds-ts_firmware
  • fx5uj-60mr\/es_firmware
  • fx5uc-32mt\/d_firmware
  • fx5uj-60mt\/es
  • fx5uj-40mt\/es_firmware
CWE
CWE-312

Cleartext Storage of Sensitive Information