Filtered by vendor Tenda
Subscribe
Total
802 CVE
CVE | Vendors | Products | Updated | CVSS v2 | CVSS v3 |
---|---|---|---|---|---|
CVE-2022-47120 | 1 Tenda | 2 A15, A15 Firmware | 2024-02-28 | N/A | 9.8 CRITICAL |
Tenda A15 V15.13.07.13 was discovered to contain a stack overflow via the security_5g parameter at /goform/WifiBasicSet. | |||||
CVE-2022-44169 | 1 Tenda | 2 Ac15, Ac15 Firmware | 2024-02-28 | N/A | 7.5 HIGH |
Tenda AC15 V15.03.05.18 is vulnerable to Buffer Overflow via function formSetVirtualSer. | |||||
CVE-2022-47126 | 1 Tenda | 2 A15, A15 Firmware | 2024-02-28 | N/A | 9.8 CRITICAL |
Tenda A15 V15.13.07.13 was discovered to contain a stack overflow via the wrlEn parameter at /goform/WifiBasicSet. | |||||
CVE-2023-27064 | 1 Tenda | 2 W15e, W15e Firmware | 2024-02-28 | N/A | 7.5 HIGH |
Tenda V15V1.0 V15.11.0.14(1521_3190_1058) was discovered to contain a buffer overflow vulnerability via the index parameter in the formDelDnsForward function. This vulnerability allows attackers to cause a Denial of Service (DoS) via a crafted request. | |||||
CVE-2022-45516 | 1 Tenda | 2 W30e, W30e Firmware | 2024-02-28 | N/A | 7.5 HIGH |
Tenda W30E V1.0.1.25(633) was discovered to contain a stack overflow via the page parameter at /goform/NatStaticSetting. | |||||
CVE-2023-24167 | 1 Tenda | 2 Ac18, Ac18 Firmware | 2024-02-28 | N/A | 9.8 CRITICAL |
Tenda AC18 V15.03.05.19 is vulnerable to Buffer Overflow via /goform/add_white_node. | |||||
CVE-2022-46533 | 1 Tenda | 2 F1203, F1203 Firmware | 2024-02-28 | N/A | 7.5 HIGH |
Tenda F1203 V2.0.1.6 was discovered to contain a buffer overflow via the limitSpeed parameter at /goform/SetClientState. | |||||
CVE-2023-25235 | 1 Tenda | 2 Ac500, Ac500 Firmware | 2024-02-28 | N/A | 7.5 HIGH |
Tenda AC500 V2.0.1.9(1307) is vulnerable to Buffer Overflow in function formOneSsidCfgSet via parameter ssid. | |||||
CVE-2022-45997 | 1 Tenda | 2 W15e, W20e Firmware | 2024-02-28 | N/A | 7.2 HIGH |
Tenda W20E V16.01.0.6(3392) is vulnerable to Buffer Overflow. | |||||
CVE-2023-25234 | 1 Tenda | 2 Ac500, Ac500 Firmware | 2024-02-28 | N/A | 9.8 CRITICAL |
Tenda AC500 V2.0.1.9(1307) is vulnerable to Buffer Overflow in function fromAddressNat via parameters entrys and mitInterface. | |||||
CVE-2022-45671 | 1 Tenda | 2 I22, I22 Firmware | 2024-02-28 | N/A | 7.5 HIGH |
Tenda i22 V1.0.0.3(4687) was discovered to contain a buffer overflow via the appData parameter in the formSetAppFilterRule function. | |||||
CVE-2022-46548 | 1 Tenda | 2 F1203, F1203 Firmware | 2024-02-28 | N/A | 7.5 HIGH |
Tenda F1203 V2.0.1.6 was discovered to contain a buffer overflow via the page parameter at /goform/DhcpListClient. | |||||
CVE-2022-46535 | 1 Tenda | 2 F1203, F1203 Firmware | 2024-02-28 | N/A | 7.5 HIGH |
Tenda F1203 V2.0.1.6 was discovered to contain a buffer overflow via the deviceId parameter at /goform/SetClientState. | |||||
CVE-2022-47125 | 1 Tenda | 2 A15, A15 Firmware | 2024-02-28 | N/A | 9.8 CRITICAL |
Tenda A15 V15.13.07.13 was discovered to contain a stack overflow via the wrlEn_5g parameter at /goform/WifiBasicSet. | |||||
CVE-2022-46536 | 1 Tenda | 2 F1203, F1203 Firmware | 2024-02-28 | N/A | 7.5 HIGH |
Tenda F1203 V2.0.1.6 was discovered to contain a buffer overflow via the limitSpeedUp parameter at /goform/SetClientState. | |||||
CVE-2022-46547 | 1 Tenda | 2 F1203, F1203 Firmware | 2024-02-28 | N/A | 7.5 HIGH |
Tenda F1203 V2.0.1.6 was discovered to contain a buffer overflow via the page parameter at /goform/VirtualSer. | |||||
CVE-2022-45672 | 1 Tenda | 2 I22, I22 Firmware | 2024-02-28 | N/A | 7.5 HIGH |
Tenda i22 V1.0.0.3(4687) was discovered to contain a buffer overflow via the formWx3AuthorizeSet function. | |||||
CVE-2022-45515 | 1 Tenda | 2 W30e, W30e Firmware | 2024-02-28 | N/A | 7.5 HIGH |
Tenda W30E V1.0.1.25(633) was discovered to contain a stack overflow via the entries parameter at /goform/addressNat. | |||||
CVE-2022-47119 | 1 Tenda | 2 A15, A15 Firmware | 2024-02-28 | N/A | 9.8 CRITICAL |
Tenda A15 V15.13.07.13 was discovered to contain a stack overflow via the ssid parameter at /goform/WifiBasicSet. | |||||
CVE-2022-44178 | 1 Tenda | 2 Ac18, Ac18 Firmware | 2024-02-28 | N/A | 9.8 CRITICAL |
Tenda AC18 V15.03.05.19 is vulnerable to Buffer Overflow. via function formWifiWpsOOB. |