Filtered by vendor Tenda
Subscribe
Total
802 CVE
CVE | Vendors | Products | Updated | CVSS v2 | CVSS v3 |
---|---|---|---|---|---|
CVE-2022-45670 | 1 Tenda | 2 I22, I22 Firmware | 2024-02-28 | N/A | 7.5 HIGH |
Tenda i22 V1.0.0.3(4687) was discovered to contain a buffer overflow via the ping1 parameter in the formSetAutoPing function. | |||||
CVE-2022-45497 | 1 Tenda | 2 W6-s, W6-s Firmware | 2024-02-28 | N/A | 9.8 CRITICAL |
Tenda W6-S v1.0.0.4(510) was discovered to contain a command injection vulnerability in the tpi_get_ping_output function at /goform/exeCommand. | |||||
CVE-2022-45506 | 1 Tenda | 2 W30e, W30e Firmware | 2024-02-28 | N/A | 9.8 CRITICAL |
Tenda W30E v1.0.1.25(633) was discovered to contain a command injection vulnerability via the fileNameMit parameter at /goform/delFileName. | |||||
CVE-2022-45668 | 1 Tenda | 2 I22, I22 Firmware | 2024-02-28 | N/A | 6.5 MEDIUM |
Tenda i22 V1.0.0.3(4687) is vulnerable to Cross Site Request Forgery (CSRF) via function fromSysToolReboot. | |||||
CVE-2022-45043 | 1 Tenda | 2 Ax12, Ax12 Firmware | 2024-02-28 | N/A | 8.8 HIGH |
Tenda AX12 V22.03.01.16_cn is vulnerable to command injection via goform/fast_setting_internet_set. | |||||
CVE-2022-45514 | 1 Tenda | 2 W30e, W30e Firmware | 2024-02-28 | N/A | 7.5 HIGH |
Tenda W30E V1.0.1.25(633) was discovered to contain a stack overflow via the page parameter at /goform/webExcptypemanFilter. | |||||
CVE-2022-45980 | 1 Tenda | 2 Ax12, Ax12 Firmware | 2024-02-28 | N/A | 8.8 HIGH |
Tenda AX12 V22.03.01.21_CN was discovered to contain a Cross-Site Request Forgery (CSRF) via /goform/SysToolRestoreSet . | |||||
CVE-2022-44180 | 1 Tenda | 2 Ac18, Ac18 Firmware | 2024-02-28 | N/A | 9.8 CRITICAL |
Tenda AC18 V15.03.05.19 is vulnerable to Buffer Overflow via function addWifiMacFilter. | |||||
CVE-2022-45523 | 1 Tenda | 2 W30e, W30e Firmware | 2024-02-28 | N/A | 7.5 HIGH |
Tenda W30E V1.0.1.25(633) was discovered to contain a stack overflow via the page parameter at /goform/L7Im. | |||||
CVE-2022-45663 | 1 Tenda | 2 I22, I22 Firmware | 2024-02-28 | N/A | 7.5 HIGH |
Tenda i22 V1.0.0.3(4687) was discovered to contain a buffer overflow via the index parameter in the formWifiMacFilterSet function. | |||||
CVE-2022-44163 | 1 Tenda | 2 Ac21, Ac21 Firmware | 2024-02-28 | N/A | 7.5 HIGH |
Tenda AC21 V16.03.08.15 is vulnerable to Buffer Overflow via function formSetMacFilterCfg. | |||||
CVE-2023-27062 | 1 Tenda | 2 W15e, W15e Firmware | 2024-02-28 | N/A | 7.5 HIGH |
Tenda V15V1.0 was discovered to contain a buffer overflow vulnerability via the gotoUrl parameter in the formPortalAuth function. This vulnerability allows attackers to cause a Denial of Service (DoS) via a crafted request. | |||||
CVE-2022-44177 | 1 Tenda | 2 Ac18, Ac18 Firmware | 2024-02-28 | N/A | 9.8 CRITICAL |
Tenda AC18 V15.03.05.19 is vulnerable to Buffer Overflow via function formWifiWpsStart. | |||||
CVE-2022-45524 | 1 Tenda | 2 W30e, W30e Firmware | 2024-02-28 | N/A | 7.5 HIGH |
Tenda W30E V1.0.1.25(633) was discovered to contain a stack overflow via the opttype parameter at /goform/IPSECsave. | |||||
CVE-2022-45979 | 1 Tenda | 2 Ax12, Ax12 Firmware | 2024-02-28 | N/A | 7.5 HIGH |
Tenda AX12 v22.03.01.21_CN was discovered to contain a stack overflow via the ssid parameter at /goform/fast_setting_wifi_set . | |||||
CVE-2022-45503 | 1 Tenda | 2 W6-s, W6-s Firmware | 2024-02-28 | N/A | 7.5 HIGH |
Tenda W6-S v1.0.0.4(510) was discovered to contain a stack overflow via the linkEn parameter at /goform/setAutoPing. | |||||
CVE-2022-45499 | 1 Tenda | 2 W6-s, W6-s Firmware | 2024-02-28 | N/A | 7.5 HIGH |
Tenda W6-S v1.0.0.4(510) was discovered to contain a stack overflow via the wl_radio parameter at /goform/WifiMacFilterGet. | |||||
CVE-2023-27239 | 1 Tenda | 2 Ax3, Ax3 Firmware | 2024-02-28 | N/A | 9.8 CRITICAL |
Tenda AX3 V16.03.12.11 was discovered to contain a stack overflow via the shareSpeed parameter at /goform/WifiGuestSet. | |||||
CVE-2022-46543 | 1 Tenda | 2 F1203, F1203 Firmware | 2024-02-28 | N/A | 7.5 HIGH |
Tenda F1203 V2.0.1.6 was discovered to contain a buffer overflow via the mitInterface parameter at /goform/addressNat. | |||||
CVE-2022-44174 | 1 Tenda | 2 Ac18, Ac18 Firmware | 2024-02-28 | N/A | 9.8 CRITICAL |
Tenda AC18 V15.03.05.05 is vulnerable to Buffer Overflow via function formSetDeviceName. |