Filtered by vendor Phoenixcontact
Subscribe
Total
113 CVE
CVE | Vendors | Products | Updated | CVSS v2 | CVSS v3 |
---|---|---|---|---|---|
CVE-2020-12499 | 1 Phoenixcontact | 1 Plcnext Engineer | 2024-11-21 | 4.4 MEDIUM | 8.2 HIGH |
In PHOENIX CONTACT PLCnext Engineer version 2020.3.1 and earlier an improper path sanitation vulnerability exists on import of project files. | |||||
CVE-2020-12498 | 1 Phoenixcontact | 2 Pc Worx, Pc Worx Express | 2024-11-21 | 6.8 MEDIUM | 7.8 HIGH |
mwe file parsing in Phoenix Contact PC Worx and PC Worx Express version 1.87 and earlier is vulnerable to out-of-bounds read remote code execution. Manipulated PC Worx projects could lead to a remote code execution due to insufficient input data validation. | |||||
CVE-2020-12497 | 1 Phoenixcontact | 2 Pc Worx, Pc Worx Express | 2024-11-21 | 6.8 MEDIUM | 7.8 HIGH |
PLCopen XML file parsing in Phoenix Contact PC Worx and PC Worx Express version 1.87 and earlier can lead to a stack-based overflow. Manipulated PC Worx projects could lead to a remote code execution due to insufficient input data validation. | |||||
CVE-2020-10940 | 1 Phoenixcontact | 3 Portico Server 16 Client, Portico Server 1 Client, Portico Server 4 Client | 2024-11-21 | 4.6 MEDIUM | 7.8 HIGH |
Local Privilege Escalation can occur in PHOENIX CONTACT PORTICO SERVER through 3.0.7 when installed to run as a service. | |||||
CVE-2020-10939 | 1 Phoenixcontact | 1 Pc Worx Srt | 2024-11-21 | 4.6 MEDIUM | 7.8 HIGH |
Insecure, default path permissions in PHOENIX CONTACT PC WORX SRT through 1.14 allow for local privilege escalation. | |||||
CVE-2019-9744 | 1 Phoenixcontact | 8 Fl Nat Smcs 8tx, Fl Nat Smcs 8tx Firmware, Fl Nat Smn 8tx and 5 more | 2024-11-21 | 6.8 MEDIUM | 8.8 HIGH |
An issue was discovered on PHOENIX CONTACT FL NAT SMCS 8TX, FL NAT SMN 8TX, FL NAT SMN 8TX-M, and FL NAT SMN 8TX-M-DMG devices. There is unauthorized access to the WEB-UI by attackers arriving from the same source IP address as an authenticated user, because this IP address is used as a session identifier. | |||||
CVE-2019-9743 | 1 Phoenixcontact | 4 Rad-80211-xd, Rad-80211-xd\/hp-bus, Rad-80211-xd\/hp-bus Firmware and 1 more | 2024-11-21 | 9.0 HIGH | 8.8 HIGH |
An issue was discovered on PHOENIX CONTACT RAD-80211-XD and RAD-80211-XD/HP-BUS devices. Command injection can occur in the WebHMI component. | |||||
CVE-2019-9201 | 1 Phoenixcontact | 16 Axc 1050, Axc 1050 Firmware, Ilc 131 Eth and 13 more | 2024-11-21 | 9.0 HIGH | 9.8 CRITICAL |
Multiple Phoenix Contact devices allow remote attackers to establish TCP sessions to port 1962 and obtain sensitive information or make changes, as demonstrated by using the Create Backup feature to traverse all directories. | |||||
CVE-2019-18352 | 1 Phoenixcontact | 4 Fl Nat 2208, Fl Nat 2208 Firmware, Fl Nat 2304-2gc-2sfp and 1 more | 2024-11-21 | 4.3 MEDIUM | 8.2 HIGH |
Improper access control exists on PHOENIX CONTACT FL NAT 2208 devices before V2.90 and FL NAT 2304-2GC-2SFP devices before V2.90 when using MAC-based port security. | |||||
CVE-2019-16675 | 1 Phoenixcontact | 3 Config\+, Pc Worx, Pc Worx Express | 2024-11-21 | 6.8 MEDIUM | 7.8 HIGH |
An issue was discovered in PHOENIX CONTACT PC Worx through 1.86, PC Worx Express through 1.86, and Config+ through 1.86. A manipulated PC Worx or Config+ project file could lead to an Out-of-bounds Read and remote code execution. The attacker needs to get access to an original PC Worx or Config+ project to be able to manipulate data inside. After manipulation, the attacker needs to exchange the original files with the manipulated ones on the application programming workstation. | |||||
CVE-2019-12871 | 1 Phoenixcontact | 1 Automationworx Software Suite | 2024-11-21 | 6.8 MEDIUM | 8.8 HIGH |
An issue was discovered in PHOENIX CONTACT PC Worx through 1.86, PC Worx Express through 1.86, and Config+ through 1.86. A manipulated PC Worx or Config+ project file could lead to a Use-After-Free and remote code execution. The attacker needs to get access to an original PC Worx or Config+ project file to be able to manipulate it. After manipulation, the attacker needs to exchange the original file with the manipulated one on the application programming workstation. | |||||
CVE-2019-12870 | 1 Phoenixcontact | 1 Automationworx Software Suite | 2024-11-21 | 6.8 MEDIUM | 8.8 HIGH |
An issue was discovered in PHOENIX CONTACT PC Worx through 1.86, PC Worx Express through 1.86, and Config+ through 1.86. A manipulated PC Worx or Config+ project file could lead to an Uninitialized Pointer and remote code execution. The attacker needs to get access to an original PC Worx or Config+ project file to be able to manipulate it. After manipulation, the attacker needs to exchange the original file with the manipulated one on the application programming workstation. | |||||
CVE-2019-12869 | 1 Phoenixcontact | 1 Automationworx Software Suite | 2024-11-21 | 6.8 MEDIUM | 8.8 HIGH |
An issue was discovered in PHOENIX CONTACT PC Worx through 1.86, PC Worx Express through 1.86, and Config+ through 1.86. A manipulated PC Worx or Config+ project file could lead to an Out-Of-Bounds Read, Information Disclosure, and remote code execution. The attacker needs to get access to an original PC Worx or Config+ project file to be able to manipulate it. After manipulation, the attacker needs to exchange the original file with the manipulated one on the application programming workstation. | |||||
CVE-2019-10998 | 1 Phoenixcontact | 4 Axc F 2152, Axc F 2152 Firmware, Axc F 2152 Starterkit and 1 more | 2024-11-21 | 4.6 MEDIUM | 6.8 MEDIUM |
An issue was discovered on Phoenix Contact AXC F 2152 (No.2404267) before 2019.0 LTS and AXC F 2152 STARTERKIT (No.1046568) before 2019.0 LTS devices. Unlimited physical access to the PLC may lead to a manipulation of SD cards data. SD card manipulation may lead to an authentication bypass opportunity. | |||||
CVE-2019-10997 | 1 Phoenixcontact | 4 Axc F 2152, Axc F 2152 Firmware, Axc F 2152 Starterkit and 1 more | 2024-11-21 | 7.1 HIGH | 5.9 MEDIUM |
An issue was discovered on Phoenix Contact AXC F 2152 (No.2404267) before 2019.0 LTS and AXC F 2152 STARTERKIT (No.1046568) before 2019.0 LTS devices. Protocol Fuzzing on PC WORX Engineer by a man in the middle attacker stops the PLC service. The device must be rebooted, or the PLC service must be restarted manually via a Linux shell. | |||||
CVE-2019-10953 | 5 Abb, Phoenixcontact, Schneider-electric and 2 more | 20 Pm554-tp-eth, Pm554-tp-eth Firmware, Ilc 151 Eth and 17 more | 2024-11-21 | 5.0 MEDIUM | 7.5 HIGH |
ABB, Phoenix Contact, Schneider Electric, Siemens, WAGO - Programmable Logic Controllers, multiple versions. Researchers have found some controllers are susceptible to a denial-of-service attack due to a flood of network packets. | |||||
CVE-2018-5441 | 1 Phoenixcontact | 46 Mguard Centerport, Mguard Centerport Firmware, Mguard Core Tx Vpn and 43 more | 2024-11-21 | 4.6 MEDIUM | 7.8 HIGH |
An Improper Validation of Integrity Check Value issue was discovered in PHOENIX CONTACT mGuard firmware versions 7.2 to 8.6.0. mGuard devices rely on internal checksums for verification of the internal integrity of the update packages. Verification may not always be performed correctly, allowing an attacker to modify firmware update packages. | |||||
CVE-2018-16994 | 1 Phoenixcontact | 6 Axl F Bk Eth, Axl F Bk Eth Firmware, Axl F Bk Eth Xc and 3 more | 2024-11-21 | 7.8 HIGH | 7.5 HIGH |
An issue was discovered on PHOENIX CONTACT AXL F BK PN <=1.0.4, AXL F BK ETH <= 1.12, and AXL F BK ETH XC <= 1.11 devices and Bosch Rexroth S20-ETH-BK and Rexroth S20-PN-BK+ (the S20-PN-BK+/S20-ETH-BK fieldbus couplers sold by Bosch Rexroth contain technology from Phoenix Contact). Incorrect handling of a request with non-standard symbols allows remote attackers to initiate a complete lock up of the bus coupler. Authentication of the request is not required. | |||||
CVE-2018-13994 | 1 Phoenixcontact | 58 Fl Switch 3004t-fx, Fl Switch 3004t-fx Firmware, Fl Switch 3004t-fx St and 55 more | 2024-11-21 | 5.0 MEDIUM | 7.5 HIGH |
The WebUI of PHOENIX CONTACT FL SWITCH 3xxx, 4xxx, 48xx versions 1.0 to 1.34 is vulnerable to a denial-of-service attack by making more than 120 connections. | |||||
CVE-2018-13993 | 1 Phoenixcontact | 58 Fl Switch 3004t-fx, Fl Switch 3004t-fx Firmware, Fl Switch 3004t-fx St and 55 more | 2024-11-21 | 6.8 MEDIUM | 8.8 HIGH |
The WebUI of PHOENIX CONTACT FL SWITCH 3xxx, 4xxx, 48xx versions 1.0 to 1.34 is prone to CSRF. |