Filtered by vendor Siemens
Subscribe
Total
1889 CVE
CVE | Vendors | Products | Updated | CVSS v2 | CVSS v3 |
---|---|---|---|---|---|
CVE-2022-43514 | 1 Siemens | 1 Automation License Manager | 2024-11-21 | N/A | 7.7 HIGH |
A vulnerability has been identified in Automation License Manager V5 (All versions), Automation License Manager V6 (All versions < V6.0 SP9 Upd4), TeleControl Server Basic V3 (All versions < V3.1.2). The affected component does not correctly validate the root path on folder related operations, allowing to modify files and folders outside the intended root directory. This could allow an unauthenticated remote attacker to execute file operations of files outside of the specified root folder. Chained with CVE-2022-43513 this could allow Remote Code Execution. | |||||
CVE-2022-43513 | 1 Siemens | 1 Automation License Manager | 2024-11-21 | N/A | 8.2 HIGH |
A vulnerability has been identified in Automation License Manager V5 (All versions), Automation License Manager V6 (All versions < V6.0 SP9 Upd4), TeleControl Server Basic V3 (All versions < V3.1.2). The affected components allow to rename license files with user chosen input without authentication. This could allow an unauthenticated remote attacker to rename and move files as SYSTEM user. | |||||
CVE-2022-43439 | 1 Siemens | 4 7kg9501-0aa01-2aa1, 7kg9501-0aa01-2aa1 Firmware, 7kg9501-0aa31-2aa1 and 1 more | 2024-11-21 | N/A | 9.9 CRITICAL |
A vulnerability has been identified in POWER METER SICAM Q100 (All versions < V2.50), POWER METER SICAM Q100 (All versions < V2.50), POWER METER SICAM Q100 (All versions < V2.50), POWER METER SICAM Q100 (All versions < V2.50), SICAM P850 (All versions < V3.10), SICAM P850 (All versions < V3.10), SICAM P850 (All versions < V3.10), SICAM P850 (All versions < V3.10), SICAM P850 (All versions < V3.10), SICAM P850 (All versions < V3.10), SICAM P850 (All versions < V3.10), SICAM P850 (All versions < V3.10), SICAM P850 (All versions < V3.10), SICAM P850 (All versions < V3.10), SICAM P850 (All versions < V3.10), SICAM P850 (All versions < V3.10), SICAM P850 (All versions < V3.10), SICAM P850 (All versions < V3.10), SICAM P850 (All versions < V3.10), SICAM P850 (All versions < V3.10), SICAM P850 (All versions < V3.10), SICAM P850 (All versions < V3.10), SICAM P855 (All versions < V3.10), SICAM P855 (All versions < V3.10), SICAM P855 (All versions < V3.10), SICAM P855 (All versions < V3.10), SICAM P855 (All versions < V3.10), SICAM P855 (All versions < V3.10), SICAM P855 (All versions < V3.10), SICAM P855 (All versions < V3.10), SICAM P855 (All versions < V3.10), SICAM P855 (All versions < V3.10), SICAM P855 (All versions < V3.10), SICAM P855 (All versions < V3.10), SICAM P855 (All versions < V3.10), SICAM P855 (All versions < V3.10), SICAM P855 (All versions < V3.10), SICAM P855 (All versions < V3.10), SICAM P855 (All versions < V3.10), SICAM P855 (All versions < V3.10). Affected devices do not properly validate the Language-parameter in requests to the web interface on port 443/tcp. This could allow an authenticated remote attacker to crash the device (followed by an automatic reboot) or to execute arbitrary code on the device. | |||||
CVE-2022-43400 | 1 Siemens | 1 Siveillance Video Mobile Server | 2024-11-21 | N/A | 9.8 CRITICAL |
A vulnerability has been identified in Siveillance Video Mobile Server V2022 R2 (All versions < V22.2a (80)). The mobile server component of affected applications improperly handles the log in for Active Directory accounts that are part of Administrators group. This could allow an unauthenticated remote attacker to access the application without a valid account. | |||||
CVE-2022-43398 | 1 Siemens | 4 7kg9501-0aa01-2aa1, 7kg9501-0aa01-2aa1 Firmware, 7kg9501-0aa31-2aa1 and 1 more | 2024-11-21 | N/A | 7.5 HIGH |
A vulnerability has been identified in POWER METER SICAM Q100 (All versions < V2.50), POWER METER SICAM Q100 (All versions < V2.50), POWER METER SICAM Q100 (All versions < V2.50), POWER METER SICAM Q100 (All versions < V2.50). Affected devices do not renew the session cookie after login/logout and also accept user defined session cookies. An attacker could overwrite the stored session cookie of a user. After the victim logged in, the attacker is given access to the user's account through the activated session. | |||||
CVE-2022-43397 | 1 Siemens | 1 Parasolid | 2024-11-21 | N/A | 7.8 HIGH |
A vulnerability has been identified in Parasolid V34.0 (All versions < V34.0.252), Parasolid V34.1 (All versions < V34.1.242), Parasolid V35.0 (All versions < V35.0.170), Simcenter Femap (All versions < V2023.1). The affected application contains an out of bounds write past the end of an allocated buffer while parsing specially crafted X_T files. This could allow an attacker to execute code in the context of the current process. (ZDI-CAN-17854) | |||||
CVE-2022-42894 | 1 Siemens | 1 Syngo Dynamics Cardiovascular Imaging And Information System | 2024-11-21 | N/A | 7.5 HIGH |
A vulnerability has been identified in syngo Dynamics (All versions < VA40G HF01). An unauthenticated Server-Side Request Forgery (SSRF) vulnerability was identified in one of the web services exposed on the syngo Dynamics application that could allow for the leaking of NTLM credentials as well as local service enumeration. | |||||
CVE-2022-42893 | 1 Siemens | 1 Syngo Dynamics Cardiovascular Imaging And Information System | 2024-11-21 | N/A | 7.5 HIGH |
A vulnerability has been identified in syngo Dynamics (All versions < VA40G HF01). syngo Dynamics application server hosts a web service using an operation with improper write access control that could allow to write data in any folder accessible to the account assigned to the website’s application pool. | |||||
CVE-2022-42892 | 1 Siemens | 1 Syngo Dynamics Cardiovascular Imaging And Information System | 2024-11-21 | N/A | 5.3 MEDIUM |
A vulnerability has been identified in syngo Dynamics (All versions < VA40G HF01). syngo Dynamics application server hosts a web service using an operation with improper write access control that could allow directory listing in any folder accessible to the account assigned to the website’s application pool. | |||||
CVE-2022-42891 | 1 Siemens | 1 Syngo Dynamics Cardiovascular Imaging And Information System | 2024-11-21 | N/A | 7.5 HIGH |
A vulnerability has been identified in syngo Dynamics (All versions < VA40G HF01). syngo Dynamics application server hosts a web service using an operation with improper write access control that could allow to write data in any folder accessible to the account assigned to the website’s application pool. | |||||
CVE-2022-42784 | 1 Siemens | 32 6ag1052-1cc08-7ba1, 6ag1052-1cc08-7ba1 Firmware, 6ag1052-1fb08-7ba1 and 29 more | 2024-11-21 | N/A | 7.6 HIGH |
A vulnerability has been identified in LOGO! 12/24RCE (6ED1052-1MD08-0BA1) (All versions >= V8.3), LOGO! 12/24RCEo (6ED1052-2MD08-0BA1) (All versions >= V8.3), LOGO! 230RCE (6ED1052-1FB08-0BA1) (All versions >= V8.3), LOGO! 230RCEo (6ED1052-2FB08-0BA1) (All versions >= V8.3), LOGO! 24CE (6ED1052-1CC08-0BA1) (All versions >= V8.3), LOGO! 24CEo (6ED1052-2CC08-0BA1) (All versions >= V8.3), LOGO! 24RCE (6ED1052-1HB08-0BA1) (All versions >= V8.3), LOGO! 24RCEo (6ED1052-2HB08-0BA1) (All versions >= V8.3), SIPLUS LOGO! 12/24RCE (6AG1052-1MD08-7BA1) (All versions >= V8.3), SIPLUS LOGO! 12/24RCEo (6AG1052-2MD08-7BA1) (All versions >= V8.3), SIPLUS LOGO! 230RCE (6AG1052-1FB08-7BA1) (All versions >= V8.3), SIPLUS LOGO! 230RCEo (6AG1052-2FB08-7BA1) (All versions >= V8.3), SIPLUS LOGO! 24CE (6AG1052-1CC08-7BA1) (All versions >= V8.3), SIPLUS LOGO! 24CEo (6AG1052-2CC08-7BA1) (All versions >= V8.3), SIPLUS LOGO! 24RCE (6AG1052-1HB08-7BA1) (All versions >= V8.3), SIPLUS LOGO! 24RCEo (6AG1052-2HB08-7BA1) (All versions >= V8.3). Affected devices are vulnerable to an electromagnetic fault injection. This could allow an attacker to dump and debug the firmware, including the manipulation of memory. Further actions could allow to inject public keys of custom created key pairs which are then signed by the product CA. The generation of a custom certificate allows communication with, and impersonation of, any device of the same version. | |||||
CVE-2022-42734 | 1 Siemens | 1 Syngo Dynamics Cardiovascular Imaging And Information System | 2024-11-21 | N/A | 7.5 HIGH |
A vulnerability has been identified in syngo Dynamics (All versions < VA40G HF01). syngo Dynamics application server hosts a web service using an operation with improper write access control that could allow to write data in any folder accessible to the account assigned to the website’s application pool. | |||||
CVE-2022-42733 | 1 Siemens | 1 Syngo Dynamics Cardiovascular Imaging And Information System | 2024-11-21 | N/A | 7.5 HIGH |
A vulnerability has been identified in syngo Dynamics (All versions < VA40G HF01). syngo Dynamics application server hosts a web service using an operation with improper read access control that could allow files to be retrieved from any folder accessible to the account assigned to the website’s application pool. | |||||
CVE-2022-42732 | 1 Siemens | 1 Syngo Dynamics Cardiovascular Imaging And Information System | 2024-11-21 | N/A | 7.5 HIGH |
A vulnerability has been identified in syngo Dynamics (All versions < VA40G HF01). syngo Dynamics application server hosts a web service using an operation with improper read access control that could allow files to be retrieved from any folder accessible to the account assigned to the website’s application pool. | |||||
CVE-2022-41851 | 1 Siemens | 2 Jt Open Toolkit, Simcenter Femap | 2024-11-21 | N/A | 7.8 HIGH |
A vulnerability has been identified in JTTK (All versions < V11.1.1.0), Simcenter Femap V2022.1 (All versions < V2022.1.3), Simcenter Femap V2022.2 (All versions < V2022.2.2). The JTTK library is vulnerable to an uninitialized pointer reference vulnerability while parsing specially crafted JT files. An attacker could leverage this vulnerability to execute code in the context of the current process. (ZDI-CAN-16973) | |||||
CVE-2022-41665 | 1 Siemens | 72 7kg8500-0aa00-0aa0, 7kg8500-0aa00-0aa0 Firmware, 7kg8500-0aa00-2aa0 and 69 more | 2024-11-21 | N/A | 9.8 CRITICAL |
A vulnerability has been identified in SICAM P850 (All versions < V3.10), SICAM P850 (All versions < V3.10), SICAM P850 (All versions < V3.10), SICAM P850 (All versions < V3.10), SICAM P850 (All versions < V3.10), SICAM P850 (All versions < V3.10), SICAM P850 (All versions < V3.10), SICAM P850 (All versions < V3.10), SICAM P850 (All versions < V3.10), SICAM P850 (All versions < V3.10), SICAM P850 (All versions < V3.10), SICAM P850 (All versions < V3.10), SICAM P850 (All versions < V3.10), SICAM P850 (All versions < V3.10), SICAM P850 (All versions < V3.10), SICAM P850 (All versions < V3.10), SICAM P850 (All versions < V3.10), SICAM P850 (All versions < V3.10), SICAM P855 (All versions < V3.10), SICAM P855 (All versions < V3.10), SICAM P855 (All versions < V3.10), SICAM P855 (All versions < V3.10), SICAM P855 (All versions < V3.10), SICAM P855 (All versions < V3.10), SICAM P855 (All versions < V3.10), SICAM P855 (All versions < V3.10), SICAM P855 (All versions < V3.10), SICAM P855 (All versions < V3.10), SICAM P855 (All versions < V3.10), SICAM P855 (All versions < V3.10), SICAM P855 (All versions < V3.10), SICAM P855 (All versions < V3.10), SICAM P855 (All versions < V3.10), SICAM P855 (All versions < V3.10), SICAM P855 (All versions < V3.10), SICAM P855 (All versions < V3.10). Affected devices do not properly validate the parameter of a specific GET request. This could allow an unauthenticated attacker to set the device to a denial of service state or to control the program counter and, thus, execute arbitrary code on the device. | |||||
CVE-2022-41664 | 1 Siemens | 2 Jt2go, Teamcenter Visualization | 2024-11-21 | N/A | 7.8 HIGH |
A vulnerability has been identified in JT2Go (All versions < V14.1.0.4), Teamcenter Visualization V13.2 (All versions < V13.2.0.12), Teamcenter Visualization V13.3 (All versions < V13.3.0.7), Teamcenter Visualization V14.0 (All versions < V14.0.0.3), Teamcenter Visualization V14.1 (All versions < V14.1.0.4). The affected application contains a stack-based buffer overflow vulnerability that could be triggered while parsing specially crafted PDF files. This could allow an attacker to execute code in the context of the current process. | |||||
CVE-2022-41663 | 1 Siemens | 2 Jt2go, Teamcenter Visualization | 2024-11-21 | N/A | 7.8 HIGH |
A vulnerability has been identified in JT2Go (All versions < V14.1.0.4), Teamcenter Visualization V13.2 (All versions < V13.2.0.12), Teamcenter Visualization V13.3 (All versions < V13.3.0.7), Teamcenter Visualization V14.0 (All versions < V14.0.0.3), Teamcenter Visualization V14.1 (All versions < V14.1.0.4). The affected applications contain a use-after-free vulnerability that could be triggered while parsing specially crafted CGM files. An attacker could leverage this vulnerability to execute code in the context of the current process. | |||||
CVE-2022-41662 | 1 Siemens | 2 Jt2go, Teamcenter Visualization | 2024-11-21 | N/A | 7.8 HIGH |
A vulnerability has been identified in JT2Go (All versions < V14.1.0.4), Teamcenter Visualization V13.2 (All versions < V13.2.0.12), Teamcenter Visualization V13.3 (All versions < V13.3.0.7), Teamcenter Visualization V14.0 (All versions < V14.0.0.3), Teamcenter Visualization V14.1 (All versions < V14.1.0.4). The affected products contain an out of bounds read vulnerability when parsing a CGM file. An attacker can leverage this vulnerability to execute code in the context of the current process. | |||||
CVE-2022-41661 | 1 Siemens | 2 Jt2go, Teamcenter Visualization | 2024-11-21 | N/A | 7.8 HIGH |
A vulnerability has been identified in JT2Go (All versions < V14.1.0.4), Teamcenter Visualization V13.2 (All versions < V13.2.0.12), Teamcenter Visualization V13.3 (All versions < V13.3.0.7), Teamcenter Visualization V14.0 (All versions < V14.0.0.3), Teamcenter Visualization V14.1 (All versions < V14.1.0.4). The affected products contain an out of bounds read vulnerability when parsing a CGM file. An attacker can leverage this vulnerability to execute code in the context of the current process. |