A vulnerability has been identified in SIMATIC Cloud Connect 7 CC712 (All versions >= V2.0 < V2.1), SIMATIC Cloud Connect 7 CC716 (All versions >= V2.0 < V2.1). The filename in the upload feature of the web based management of the affected device is susceptible to a path traversal vulnerability. This could allow an authenticated privileged remote attacker to write any file with the extension `.db`.
References
Link | Resource |
---|---|
https://cert-portal.siemens.com/productcert/pdf/ssa-555292.pdf | Patch Vendor Advisory |
https://cert-portal.siemens.com/productcert/pdf/ssa-555292.pdf | Patch Vendor Advisory |
Configurations
History
21 Nov 2024, 07:56
Type | Values Removed | Values Added |
---|---|---|
References | () https://cert-portal.siemens.com/productcert/pdf/ssa-555292.pdf - Patch, Vendor Advisory | |
CVSS |
v2 : v3 : |
v2 : unknown
v3 : 3.8 |
Information
Published : 2023-05-09 13:15
Updated : 2024-11-21 07:56
NVD link : CVE-2023-29128
Mitre link : CVE-2023-29128
CVE.ORG link : CVE-2023-29128
JSON object : View
Products Affected
siemens
- 6gk1411-5ac00_firmware
- 6gk1411-5ac00
- 6gk1411-1ac00
- 6gk1411-1ac00_firmware
CWE
CWE-22
Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal')