Vulnerabilities (CVE)

Filtered by vendor Tenda Subscribe
Total 804 CVE
CVE Vendors Products Updated CVSS v2 CVSS v3
CVE-2023-37714 1 Tenda 8 Ac7, Ac7 Firmware, F1202 and 5 more 2024-11-21 N/A 9.8 CRITICAL
Tenda F1202 V1.0BR_V1.2.0.20(408), FH1202_V1.2.0.19_EN were discovered to contain a stack overflow in the page parameter in the function fromRouteStatic.
CVE-2023-37712 1 Tenda 6 Ac1206, Ac1206 Firmware, F1202 and 3 more 2024-11-21 N/A 9.8 CRITICAL
Tenda AC1206 V15.03.06.23, F1202 V1.2.0.20(408), and FH1202 V1.2.0.20(408) were discovered to contain a stack overflow in the page parameter in the fromSetIpBind function.
CVE-2023-37711 1 Tenda 4 Ac10, Ac10 Firmware, Ac1206 and 1 more 2024-11-21 N/A 9.8 CRITICAL
Tenda AC1206 V15.03.06.23 and AC10 V15.03.06.47 were discovered to contain a stack overflow in the deviceId parameter in the saveParentControlInfo function.
CVE-2023-37710 1 Tenda 4 Ac10, Ac10 Firmware, Ac1206 and 1 more 2024-11-21 N/A 9.8 CRITICAL
Tenda AC1206 V15.03.06.23 and AC10 V15.03.06.47 were discovered to contain a stack overflow in the wpapsk_crypto parameter in the fromSetWirelessRepeat function.
CVE-2023-37707 1 Tenda 2 Fh1203, Fh1203 Firmware 2024-11-21 N/A 9.8 CRITICAL
Tenda FH1203 V2.0.1.6 was discovered to contain a stack overflow via the page parameter in the fromVirtualSer function.
CVE-2023-37706 1 Tenda 2 Fh1203, Fh1203 Firmware 2024-11-21 N/A 9.8 CRITICAL
Tenda FH1203 V2.0.1.6 was discovered to contain a stack overflow via the entrys parameter in the fromAddressNat function.
CVE-2023-37705 1 Tenda 2 Fh1203, Fh1203 Firmware 2024-11-21 N/A 9.8 CRITICAL
Tenda FH1203 V2.0.1.6 was discovered to contain a stack overflow via the page parameter in the fromAddressNat function.
CVE-2023-37704 1 Tenda 2 Fh1203, Fh1203 Firmware 2024-11-21 N/A 9.8 CRITICAL
Tenda FH1203 V2.0.1.6 was discovered to contain a stack overflow via the deviceId parameter in the formSetClientState function.
CVE-2023-37703 1 Tenda 2 Fh1203, Fh1203 Firmware 2024-11-21 N/A 9.8 CRITICAL
Tenda FH1203 V2.0.1.6 was discovered to contain a stack overflow via the speed_dir parameter in the formSetSpeedWan function.
CVE-2023-37702 1 Tenda 2 Fh1203, Fh1203 Firmware 2024-11-21 N/A 9.8 CRITICAL
Tenda FH1203 V2.0.1.6 was discovered to contain a stack overflow via the deviceId parameter in the formSetDeviceName function.
CVE-2023-37701 1 Tenda 2 Fh1203, Fh1203 Firmware 2024-11-21 N/A 9.8 CRITICAL
Tenda FH1203 V2.0.1.6 was discovered to contain a stack overflow via the deviceId parameter in the addWifiMacFilter function.
CVE-2023-37700 1 Tenda 2 Fh1203, Fh1203 Firmware 2024-11-21 N/A 9.8 CRITICAL
Tenda FH1203 V2.0.1.6 was discovered to contain a stack overflow via the ssid parameter in the form_fast_setting_wifi_set function.
CVE-2023-37144 2 Tenda, Tendacn 2 Ac10, Ac10 Firmware 2024-11-21 N/A 9.8 CRITICAL
Tenda AC10 v15.03.06.26 was discovered to contain a command injection vulnerability via the mac parameter in the function formWriteFacMac.
CVE-2023-34571 1 Tenda 2 Ac10, Ac10 Firmware 2024-11-21 N/A 6.7 MEDIUM
Tenda AC10 v4 US_AC10V4.0si_V16.03.10.13_cn was discovered to contain a stack overflow via parameter shareSpeed at /goform/WifiGuestSet.
CVE-2023-34570 1 Tenda 2 Ac10, Ac10 Firmware 2024-11-21 N/A 6.7 MEDIUM
Tenda AC10 v4 US_AC10V4.0si_V16.03.10.13_cn was discovered to contain a stack overflow via parameter devName at /goform/SetOnlineDevName.
CVE-2023-34569 1 Tenda 2 Ac10, Ac10 Firmware 2024-11-21 N/A 6.7 MEDIUM
Tenda AC10 v4 US_AC10V4.0si_V16.03.10.13_cn was discovered to contain a stack overflow via parameter list at /goform/SetNetControlList.
CVE-2023-34568 1 Tenda 2 Ac10, Ac10 Firmware 2024-11-21 N/A 6.7 MEDIUM
Tenda AC10 v4 US_AC10V4.0si_V16.03.10.13_cn was discovered to contain a stack overflow via parameter time at /goform/PowerSaveSet.
CVE-2023-34567 1 Tenda 2 Ac10, Ac10 Firmware 2024-11-21 N/A 6.7 MEDIUM
Tenda AC10 v4 US_AC10V4.0si_V16.03.10.13_cn was discovered to contain a stack overflow via parameter list at /goform/SetVirtualServerCfg.
CVE-2023-34566 1 Tenda 2 Ac10, Ac10 Firmware 2024-11-21 N/A 9.8 CRITICAL
Tenda AC10 v4 US_AC10V4.0si_V16.03.10.13_cn was discovered to contain a stack overflow via parameter time at /goform/saveParentControlInfo.
CVE-2023-33675 1 Tenda 2 Ac8, Ac8 Firmware 2024-11-21 N/A 9.8 CRITICAL
Tenda AC8V4.0-V16.03.34.06 was discovered to contain a stack overflow via the time parameter in the get_parentControl_list_Info function.