Total
1271 CVE
CVE | Vendors | Products | Updated | CVSS v2 | CVSS v3 |
---|---|---|---|---|---|
CVE-2022-26119 | 1 Fortinet | 1 Fortisiem | 2024-02-28 | N/A | 7.8 HIGH |
A improper authentication vulnerability in Fortinet FortiSIEM before 6.5.0 allows a local attacker with CLI access to perform operations on the Glassfish server directly via a hardcoded password. | |||||
CVE-2022-29962 | 1 Emerson | 48 Deltav Distributed Control System Sq Controller, Deltav Distributed Control System Sq Controller Firmware, Deltav Distributed Control System Sx Controller and 45 more | 2024-02-28 | N/A | 5.5 MEDIUM |
The Emerson DeltaV Distributed Control System (DCS) controllers and IO cards through 2022-04-29 misuse passwords. FTP has hardcoded credentials (but may often be disabled in production). This affects S-series, P-series, and CIOC/EIOC nodes. NOTE: this is different from CVE-2014-2350. | |||||
CVE-2022-34907 | 1 Filewave | 1 Filewave | 2024-02-28 | N/A | 9.8 CRITICAL |
An authentication bypass vulnerability exists in FileWave before 14.6.3 and 14.7.x before 14.7.2. Exploitation could allow an unauthenticated actor to gain access to the system with the highest authority possible and gain full control over the FileWave platform. | |||||
CVE-2022-29953 | 1 Bakerhughes | 8 Bently Nevada 3701\/40, Bently Nevada 3701\/40 Firmware, Bently Nevada 3701\/44 and 5 more | 2024-02-28 | N/A | 9.8 CRITICAL |
The Bently Nevada 3700 series of condition monitoring equipment through 2022-04-29 has a maintenance interface on port 4001/TCP with undocumented, hardcoded credentials. An attacker capable of connecting to this interface can thus trivially take over its functionality. | |||||
CVE-2022-22522 | 1 Gavazziautomation | 3 Cpy Car Park Server, Uwp 3.0 Monitoring Gateway And Controller, Uwp 3.0 Monitoring Gateway And Controller Firmware | 2024-02-28 | N/A | 9.8 CRITICAL |
In Carlo Gavazzi UWP3.0 in multiple versions and CPY Car Park Server in Version 2.8.3 a remote, unauthenticated attacker could make use of hard-coded credentials to gain full access to the device. | |||||
CVE-2022-32985 | 1 Nexans | 26 Gigaswitch 641 Desk V5 Sfp-vi, Gigaswitch 641 Desk V5 Sfp-vi Firmware, Gigaswitch 642 Desk V5 Sfp-2vi and 23 more | 2024-02-28 | N/A | 9.8 CRITICAL |
libnx_apl.so on Nexans FTTO GigaSwitch before 6.02N and 7.x before 7.02 implements a Backdoor Account for SSH logins on port 50200 or 50201. | |||||
CVE-2020-15327 | 1 Zyxel | 1 Cloudcnm Secumanager | 2024-02-28 | N/A | 7.5 HIGH |
Zyxel CloudCNM SecuManager 3.1.0 and 3.1.1 uses ZODB storage without authentication. | |||||
CVE-2022-30036 | 1 Malighting | 2 Grandma2 Light, Grandma2 Light Firmware | 2024-02-28 | N/A | 8.8 HIGH |
MA Lighting grandMA2 Light has a password of root for the root account. NOTE: The vendor's position is that the product was designed for isolated networks. Also, the successor product, grandMA3, is not affected by this vulnerability. | |||||
CVE-2022-32965 | 1 Omicard Edm Project | 1 Omicard Edm | 2024-02-28 | N/A | 9.8 CRITICAL |
OMICARD EDM has a hard-coded machine key. An unauthenticated remote attacker can use the machine key to send serialized payload to the server to execute arbitrary code, manipulate system data and disrupt service. | |||||
CVE-2022-1400 | 1 Device42 | 1 Cmdb | 2024-02-28 | N/A | 9.8 CRITICAL |
Use of Hard-coded Cryptographic Key vulnerability in the WebReportsApi.dll of Exago Web Reports, as used in the Device42 Asset Management Appliance, allows an attacker to leak session IDs and elevate privileges. This issue affects: Device42 CMDB versions prior to 18.01.00. | |||||
CVE-2020-15326 | 1 Zyxel | 1 Cloudcnm Secumanager | 2024-02-28 | N/A | 5.3 MEDIUM |
Zyxel CloudCNM SecuManager 3.1.0 and 3.1.1 has a hardcoded certificate for Ejabberd in ejabberd.pem. | |||||
CVE-2022-35857 | 1 Kvf-admin Project | 1 Kvf-admin | 2024-02-28 | N/A | 9.8 CRITICAL |
kvf-admin through 2022-02-12 allows remote attackers to execute arbitrary code because deserialization is mishandled. The rememberMe parameter is encrypted with a hardcoded key from the com.kalvin.kvf.common.shiro.ShiroConfig file. | |||||
CVE-2022-30274 | 1 Motorola | 2 Ace1000, Ace1000 Firmware | 2024-02-28 | N/A | 9.8 CRITICAL |
The Motorola ACE1000 RTU through 2022-05-02 uses ECB encryption unsafely. It can communicate with an XRT LAN-to-radio gateway by means of an embedded client. Credentials for accessing this gateway are stored after being encrypted with the Tiny Encryption Algorithm (TEA) in ECB mode using a hardcoded key. Similarly, the ACE1000 RTU can route MDLC traffic over Extended Command and Management Protocol (XCMP) and Network Layer (XNL) networks via the MDLC driver. Authentication to the XNL port is protected by TEA in ECB mode using a hardcoded key. | |||||
CVE-2022-30622 | 1 Chcnav | 2 P5e Gnss, P5e Gnss Firmware | 2024-02-28 | N/A | 7.3 HIGH |
Disclosure of information - the system allows you to view usernames and passwords without permissions, thus it will be possible to enter the system. Path access: http://api/sys_username_passwd.cmd - The server loads the request clearly by default. Disclosure of hard-coded credit information within the JS code sent to the customer within the Login.js file is a strong user (which is not documented) and also the password, which allow for super-user access. Username: chcadmin, Password: chcpassword. | |||||
CVE-2021-4228 | 1 Lannerinc | 2 Iac-ast2500, Iac-ast2500 Firmware | 2024-02-28 | N/A | 7.4 HIGH |
Use of hard-coded TLS certificate by default allows an attacker to perform Man-in-the-Middle (MitM) attacks even in the presence of the HTTPS connection. This issue affects: Lanner Inc IAC-AST2500A standard firmware version 1.00.0. | |||||
CVE-2022-30318 | 1 Honeywell | 4 Controledge Plc, Controledge Plc Firmware, Controledge Rtu and 1 more | 2024-02-28 | N/A | 9.8 CRITICAL |
Honeywell ControlEdge through R151.1 uses Hard-coded Credentials. According to FSCT-2022-0056, there is a Honeywell ControlEdge hardcoded credentials issue. The affected components are characterized as: SSH. The potential impact is: Remote code execution, manipulate configuration, denial of service. The Honeywell ControlEdge PLC and RTU product line exposes an SSH service on port 22/TCP. Login as root to this service is permitted and credentials for the root user are hardcoded without automatically changing them upon first commissioning. The credentials for the SSH service are hardcoded in the firmware. The credentials grant an attacker access to a root shell on the PLC/RTU, allowing for remote code execution, configuration manipulation and denial of service. | |||||
CVE-2022-36558 | 1 Seiko-sol | 4 Skybridge Mb-a100, Skybridge Mb-a100 Firmware, Skybridge Mb-a110 and 1 more | 2024-02-28 | N/A | 9.8 CRITICAL |
Seiko SkyBridge MB-A100/A110 v4.2.0 and below implements a hard-coded passcode for the root account. Attackers are able to access the passcord via the file /etc/ciel.cfg. | |||||
CVE-2021-22644 | 1 Ovarro | 15 Tbox Lt2-530, Tbox Lt2-530 Firmware, Tbox Lt2-532 and 12 more | 2024-02-28 | N/A | 9.8 CRITICAL |
Ovarro TBox TWinSoft uses the custom hardcoded user “TWinSoft” with a hardcoded key. | |||||
CVE-2022-29960 | 1 Emerson | 1 Openbsi | 2024-02-28 | N/A | 5.5 MEDIUM |
Emerson OpenBSI through 2022-04-29 uses weak cryptography. It is an engineering environment for the ControlWave and Bristol Babcock line of RTUs. DES with hardcoded cryptographic keys is used for protection of certain system credentials, engineering files, and sensitive utilities. | |||||
CVE-2022-35413 | 1 Pentasecurity | 1 Wapples | 2024-02-28 | N/A | 9.8 CRITICAL |
WAPPLES through 6.0 has a hardcoded systemi account. A threat actor could use this account to access the system configuration and confidential information (such as SSL keys) via an HTTPS request to the /webapi/ URI on port 443 or 5001. |