Total
51 CVE
CVE | Vendors | Products | Updated | CVSS v2 | CVSS v3 |
---|---|---|---|---|---|
CVE-2021-25973 | 1 Publify Project | 1 Publify | 2024-11-21 | 6.4 MEDIUM | 6.5 MEDIUM |
In Publify, 9.0.0.pre1 to 9.2.4 are vulnerable to Improper Access Control. “guest” role users can self-register even when the admin does not allow. This happens due to front-end restriction only. | |||||
CVE-2021-24602 | 1 Hmplugin | 1 Hm Multiple Roles | 2024-11-21 | 6.5 MEDIUM | 8.8 HIGH |
The HM Multiple Roles WordPress plugin before 1.3 does not have any access control to prevent low privilege users to set themselves as admin via their profile page | |||||
CVE-2021-22900 | 2 Ivanti, Pulsesecure | 2 Connect Secure, Pulse Connect Secure | 2024-11-21 | 6.5 MEDIUM | 7.2 HIGH |
A vulnerability allowed multiple unrestricted uploads in Pulse Connect Secure before 9.1R11.4 that could lead to an authenticated administrator to perform a file write via a maliciously crafted archive upload in the administrator web interface. | |||||
CVE-2021-22806 | 1 Schneider-electric | 6 Fellerlynk, Fellerlynk Firmware, Spacelynk and 3 more | 2024-11-21 | 5.0 MEDIUM | 7.5 HIGH |
A CWE-669: Incorrect Resource Transfer Between Spheres vulnerability exists that could cause data exfiltration and unauthorized access when accessing a malicious website. Affected Product: spaceLYnk (V2.6.1 and prior), Wiser for KNX (V2.6.1 and prior), fellerLYnk (V2.6.1 and prior) | |||||
CVE-2021-21531 | 1 Dell | 5 Powermax Os, Solutions Enabler, Solutions Enabler Virtual Appliance and 2 more | 2024-11-21 | 4.6 MEDIUM | 8.1 HIGH |
Dell Unisphere for PowerMax versions prior to 9.2.1.6 contain an Authorization Bypass Vulnerability. A local authenticated malicious user with monitor role may exploit this vulnerability to perform unauthorized actions. | |||||
CVE-2021-20411 | 2 Ibm, Linux | 2 Security Verify Information Queue, Linux Kernel | 2024-11-21 | 4.8 MEDIUM | 8.1 HIGH |
IBM Security Verify Information Queue 1.0.6 and 1.0.7 could allow a user to impersonate another user on the system due to incorrectly updating the session identifier. IBM X-Force ID: 198191. | |||||
CVE-2020-6862 | 1 Zte | 2 F6x2w, F6x2w Firmware | 2024-11-21 | 5.0 MEDIUM | 5.3 MEDIUM |
V6.0.10P2T2 and V6.0.10P2T5 of F6x2W product are impacted by Information leak vulnerability. Unauthorized users could log in directly to obtain page information without entering a verification code. | |||||
CVE-2020-5800 | 1 Eat Spray Love Project | 1 Eat Spray Love | 2024-11-21 | 7.5 HIGH | 9.8 CRITICAL |
The Eat Spray Love mobile app for both iOS and Android contains logic that allows users to bypass authentication and retrieve or modify information that they would not normally have access to. | |||||
CVE-2020-5188 | 1 Dnnsoftware | 1 Dotnetnuke | 2024-11-21 | 4.0 MEDIUM | 6.5 MEDIUM |
DNN (formerly DotNetNuke) through 9.4.4 has Insecure Permissions. | |||||
CVE-2020-27268 | 1 Sooil | 6 Anydana-a, Anydana-a Firmware, Anydana-i and 3 more | 2024-11-21 | 3.3 LOW | 6.5 MEDIUM |
In SOOIL Developments Co., Ltd Diabecare RS, AnyDana-i and AnyDana-A, a client-side control vulnerability in the insulin pump and its AnyDana-i and AnyDana-A mobile applications allows physically proximate attackers to bypass checks for default PINs via Bluetooth Low Energy. | |||||
CVE-2020-26177 | 1 Tangro | 1 Business Workflow | 2024-11-21 | 4.0 MEDIUM | 4.3 MEDIUM |
In tangro Business Workflow before 1.18.1, a user's profile contains some items that are greyed out and thus are not intended to be edited by regular users. However, this restriction is only applied client-side. Manipulating any of the greyed-out values in requests to /api/profile is not prohibited server-side. | |||||
CVE-2020-25917 | 1 Stratodesk | 1 Notouch Center | 2024-11-21 | 6.5 MEDIUM | 8.8 HIGH |
Stratodesk NoTouch Center before 4.4.68 is affected by: Incorrect Access Control. A low privileged user on the platform, for example a user with "helpdesk" privileges, can perform privileged operations including adding a new administrator to the platform via the easyadmin/user/submitCreateTCUser.do page. | |||||
CVE-2020-24683 | 1 Abb | 2 Symphony \+ Historian, Symphony \+ Operations | 2024-11-21 | 7.5 HIGH | 9.8 CRITICAL |
The affected versions of S+ Operations (version 2.1 SP1 and earlier) used an approach for user authentication which relies on validation at the client node (client-side authentication). This is not as secure as having the server validate a client application before allowing a connection. Therefore, if the network communication or endpoints for these applications are not protected, unauthorized actors can bypass authentication and make unauthorized connections to the server application. | |||||
CVE-2020-1048 | 1 Microsoft | 8 Windows 10, Windows 7, Windows 8.1 and 5 more | 2024-11-21 | 7.2 HIGH | 7.8 HIGH |
An elevation of privilege vulnerability exists when the Windows Print Spooler service improperly allows arbitrary writing to the file system, aka 'Windows Print Spooler Elevation of Privilege Vulnerability'. This CVE ID is unique from CVE-2020-1070. | |||||
CVE-2020-15892 | 1 Dlink | 2 Dap-1520, Dap-1520 Firmware | 2024-11-21 | 7.5 HIGH | 9.8 CRITICAL |
An issue was discovered in apply.cgi on D-Link DAP-1520 devices before 1.10b04Beta02. Whenever a user performs a login action from the web interface, the request values are being forwarded to the ssi binary. On the login page, the web interface restricts the password input field to a fixed length of 15 characters. The problem is that validation is being done on the client side, hence it can be bypassed. When an attacker manages to intercept the login request (POST based) and tampers with the vulnerable parameter (log_pass), to a larger length, the request will be forwarded to the webserver. This results in a stack-based buffer overflow. A few other POST variables, (transferred as part of the login request) are also vulnerable: html_response_page and log_user. | |||||
CVE-2020-15257 | 3 Debian, Fedoraproject, Linuxfoundation | 3 Debian Linux, Fedora, Containerd | 2024-11-21 | 3.6 LOW | 5.2 MEDIUM |
containerd is an industry-standard container runtime and is available as a daemon for Linux and Windows. In containerd before versions 1.3.9 and 1.4.3, the containerd-shim API is improperly exposed to host network containers. Access controls for the shim’s API socket verified that the connecting process had an effective UID of 0, but did not otherwise restrict access to the abstract Unix domain socket. This would allow malicious containers running in the same network namespace as the shim, with an effective UID of 0 but otherwise reduced privileges, to cause new processes to be run with elevated privileges. This vulnerability has been fixed in containerd 1.3.9 and 1.4.3. Users should update to these versions as soon as they are released. It should be noted that containers started with an old version of containerd-shim should be stopped and restarted, as running containers will continue to be vulnerable even after an upgrade. If you are not providing the ability for untrusted users to start containers in the same network namespace as the shim (typically the "host" network namespace, for example with docker run --net=host or hostNetwork: true in a Kubernetes pod) and run with an effective UID of 0, you are not vulnerable to this issue. If you are running containers with a vulnerable configuration, you can deny access to all abstract sockets with AppArmor by adding a line similar to deny unix addr=@**, to your policy. It is best practice to run containers with a reduced set of privileges, with a non-zero UID, and with isolated namespaces. The containerd maintainers strongly advise against sharing namespaces with the host. Reducing the set of isolation mechanisms used for a container necessarily increases that container's privilege, regardless of what container runtime is used for running that container. | |||||
CVE-2020-10778 | 1 Redhat | 1 Cloudforms | 2024-11-21 | 6.5 MEDIUM | 6.0 MEDIUM |
In Red Hat CloudForms 4.7 and 5, the read only widgets can be edited by inspecting the forms and dropping the disabled attribute from the fields since there is no server-side validation. This business logic flaw violate the expected behavior. | |||||
CVE-2019-13266 | 1 Tp-link | 4 Archer C2 V1, Archer C2 V1 Firmware, Archer C3200 V1 and 1 more | 2024-11-21 | 5.8 MEDIUM | 8.8 HIGH |
TP-Link Archer C3200 V1 and Archer C2 V1 devices have Insufficient Compartmentalization between a host network and a guest network that are established by the same device. A DHCP Request is sent to the router with a certain Transaction ID field. Following the DHCP protocol, the router responds with an ACK or NAK message. Studying the NAK case revealed that the router erroneously sends the NAK to both Host and Guest networks with the same Transaction ID as found in the DHCP Request. This allows encoding of data to be sent cross-router into the 32-bit Transaction ID field. | |||||
CVE-2019-13263 | 1 Dlink | 2 Dir-825\/ac G1, Dir-825\/ac G1 Firmware | 2024-11-21 | 5.8 MEDIUM | 8.8 HIGH |
D-link DIR-825AC G1 devices have Insufficient Compartmentalization between a host network and a guest network that are established by the same device. A DHCP Request is sent to the router with a certain Transaction ID field. Following the DHCP protocol, the router responds with an ACK or NAK message. Studying the NAK case revealed that the router erroneously sends the NAK to both Host and Guest networks with the same Transaction ID as found in the DHCP Request. This allows encoding of data to be sent cross-router into the 32-bit Transaction ID field. | |||||
CVE-2019-13025 | 1 Compal | 2 Ch7465lg, Ch7465lg Firmware | 2024-11-21 | 7.5 HIGH | 9.8 CRITICAL |
Compal CH7465LG CH7465LG-NCIP-6.12.18.24-5p8-NOSH devices have Incorrect Access Control because of Improper Input Validation. The attacker can send a maliciously modified POST (HTTP) request containing shell commands, which will be executed on the device, to an backend API endpoint of the cable modem. |