Total
1225 CVE
CVE | Vendors | Products | Updated | CVSS v2 | CVSS v3 |
---|---|---|---|---|---|
CVE-2022-31266 | 1 Ilias | 1 Ilias | 2024-11-21 | 7.5 HIGH | 4.3 MEDIUM |
In ILIAS through 7.10, lack of verification when changing an email address (on the Profile Page) allows remote attackers to take over accounts. | |||||
CVE-2022-31260 | 1 Montala | 1 Resourcespace | 2024-11-21 | N/A | 6.5 MEDIUM |
In Montala ResourceSpace through 9.8 before r19636, csv_export_results_metadata.php allows attackers to export collection metadata via a non-NULL k value. | |||||
CVE-2022-31176 | 1 Grafana | 1 Grafana-image-renderer | 2024-11-21 | N/A | 8.3 HIGH |
Grafana Image Renderer is a Grafana backend plugin that handles rendering of panels & dashboards to PNGs using a headless browser (Chromium/Chrome). An internal security review identified an unauthorized file disclosure vulnerability. It is possible for a malicious user to retrieve unauthorized files under some network conditions or via a fake datasource (if user has admin permissions in Grafana). All Grafana installations should be upgraded to version 3.6.1 as soon as possible. As a workaround it is possible to [disable HTTP remote rendering](https://grafana.com/docs/grafana/latest/setup-grafana/configure-grafana/#plugingrafana-image-renderer). | |||||
CVE-2022-31022 | 1 Couchbase | 1 Bleve | 2024-11-21 | 2.1 LOW | 6.2 MEDIUM |
Bleve is a text indexing library for go. Bleve includes HTTP utilities under bleve/http package, that are used by its sample application. These HTTP methods pave way for exploitation of a node’s filesystem where the bleve index resides, if the user has used bleve’s own HTTP (bleve/http) handlers for exposing the access to the indexes. For instance, the CreateIndexHandler (`http/index_create.go`) and DeleteIndexHandler (`http/index_delete.go`) enable an attacker to create a bleve index (directory structure) anywhere where the user running the server has the write permissions and to delete recursively any directory owned by the same user account. Users who have used the bleve/http package for exposing access to bleve index without the explicit handling for the Role Based Access Controls(RBAC) of the index assets would be impacted by this issue. There is no patch for this issue because the http package is purely intended to be used for demonstration purposes. Bleve was never designed handle the RBACs, nor it was ever advertised to be used in that way. The collaborators of this project have decided to stay away from adding any authentication or authorization to bleve project at the moment. The bleve/http package is mainly for demonstration purposes and it lacks exhaustive validation of the user inputs as well as any authentication and authorization measures. It is recommended to not use bleve/http in production use cases. | |||||
CVE-2022-30515 | 1 Zkteco | 1 Biotime | 2024-11-21 | N/A | 5.3 MEDIUM |
ZKTeco BioTime 8.5.4 is missing authentication on folders containing employee photos, allowing an attacker to view them through filename enumeration. | |||||
CVE-2022-30317 | 1 Honeywell | 2 Experion Lx, Experion Lx Firmware | 2024-11-21 | N/A | 9.1 CRITICAL |
Honeywell Experion LX through 2022-05-06 has Missing Authentication for a Critical Function. According to FSCT-2022-0055, there is a Honeywell Experion LX Control Data Access (CDA) EpicMo protocol with unauthenticated functionality issue. The affected components are characterized as: Honeywell Control Data Access (CDA) EpicMo (55565/TCP). The potential impact is: Firmware manipulation, Denial of service. The Honeywell Experion LX Distributed Control System (DCS) utilizes the Control Data Access (CDA) EpicMo protocol (55565/TCP) for device diagnostics and maintenance purposes. This protocol does not have any authentication features, allowing any attacker capable of communicating with the ports in question to invoke (a subset of) desired functionality. There is no authentication functionality on the protocol in question. An attacker capable of invoking the protocols' functionalities could issue firmware download commands potentially allowing for firmware manipulation and reboot devices causing denial of service. | |||||
CVE-2022-30313 | 1 Honeywell | 2 Safety Manager, Safety Manager Firmware | 2024-11-21 | N/A | 7.5 HIGH |
Honeywell Experion PKS Safety Manager through 2022-05-06 has Missing Authentication for a Critical Function. According to FSCT-2022-0051, there is a Honeywell Experion PKS Safety Manager multiple proprietary protocols with unauthenticated functionality issue. The affected components are characterized as: Honeywell Experion TCP (51000/TCP), Safety Builder (51010/TCP). The potential impact is: Manipulate controller state, Manipulate controller configuration, Manipulate controller logic, Manipulate controller files, Manipulate IO. The Honeywell Experion PKS Distributed Control System (DCS) Safety Manager utilizes several proprietary protocols for a wide variety of functionality, including process data acquisition, controller steering and configuration management. These protocols include: Experion TCP (51000/TCP) and Safety Builder (51010/TCP). None of these protocols have any authentication features, allowing any attacker capable of communicating with the ports in question to invoke (a subset of) desired functionality. There is no authentication functionality on the protocols in question. An attacker capable of invoking the protocols' functionalities could achieve a wide range of adverse impacts, including (but not limited to), the following: for Experion TCP (51000/TCP): Issue IO manipulation commands, Issue file read/write commands; and for Safety Builder (51010/TCP): Issue controller start/stop commands, Issue logic download/upload commands, Issue file read commands, Issue system time change commands. A mitigating factor with regards to some, but not all, of the above functionality is that these require the Safety Manager physical keyswitch to be in the right position. | |||||
CVE-2022-30276 | 1 Motorola | 4 Ace Ip Gateway \(4600\), Ace Ip Gateway \(4600\) Firmware, Moscad Ip Gateway and 1 more | 2024-11-21 | N/A | 7.5 HIGH |
The Motorola MOSCAD and ACE line of RTUs through 2022-05-02 omit an authentication requirement. They feature IP Gateway modules which allow for interfacing between Motorola Data Link Communication (MDLC) networks (potentially over a variety of serial, RF and/or Ethernet links) and TCP/IP networks. Communication with RTUs behind the gateway is done by means of the proprietary IPGW protocol (5001/TCP). This protocol does not have any authentication features, allowing any attacker capable of communicating with the port in question to invoke (a subset of) desired functionality. | |||||
CVE-2022-30230 | 1 Siemens | 1 Sicam Gridedge Essential | 2024-11-21 | 7.5 HIGH | 9.8 CRITICAL |
A vulnerability has been identified in SICAM GridEdge Essential ARM (All versions < V2.6.6), SICAM GridEdge Essential Intel (All versions < V2.6.6), SICAM GridEdge Essential with GDS ARM (All versions < V2.6.6), SICAM GridEdge Essential with GDS Intel (All versions < V2.6.6). The affected software does not require authenticated access for privileged functions. This could allow an unauthenticated attacker to create a new user with administrative permissions. | |||||
CVE-2022-2765 | 1 Company Website Cms Project | 1 Company Website Cms | 2024-11-21 | N/A | 6.3 MEDIUM |
A vulnerability was found in SourceCodester Company Website CMS 1.0. It has been declared as critical. Affected by this vulnerability is an unknown functionality of the file /dashboard/settings. The manipulation leads to improper authentication. The attack can be launched remotely. The exploit has been disclosed to the public and may be used. The identifier VDB-206161 was assigned to this vulnerability. | |||||
CVE-2022-2474 | 1 Haascnc | 2 Haas Controller, Haas Controller Firmware | 2024-11-21 | N/A | 9.8 CRITICAL |
Authentication is currently unsupported in Haas Controller version 100.20.000.1110 when using the “Ethernet Q Commands” service, which allows any user on the same network segment as the controller (even while connected remotely) to access the service and write unauthorized macros to the device. | |||||
CVE-2022-2242 | 1 Kuka | 1 Systemsoftware V\/kss | 2024-11-21 | N/A | 9.8 CRITICAL |
The KUKA SystemSoftware V/KSS in versions prior to 8.6.5 is prone to improper access control as an unauthorized attacker can directly read and write robot configurations when access control is not available or not enabled (default). | |||||
CVE-2022-2141 | 1 Micodus | 2 Mv720, Mv720 Firmware | 2024-11-21 | N/A | 9.8 CRITICAL |
SMS-based GPS commands can be executed by MiCODUS MV720 GPS tracker without authentication. | |||||
CVE-2022-2138 | 1 Advantech | 1 Iview | 2024-11-21 | N/A | 8.2 HIGH |
The affected product is vulnerable due to missing authentication, which may allow an attacker to read or modify sensitive data and execute arbitrary code, resulting in a denial-of-service condition. | |||||
CVE-2022-29957 | 1 Emerson | 1 Deltav Distributed Control System | 2024-11-21 | N/A | 7.8 HIGH |
The Emerson DeltaV Distributed Control System (DCS) through 2022-04-29 mishandles authentication. It utilizes several proprietary protocols for a wide variety of functionality. These protocols include Firmware upgrade (18508/TCP, 18518/TCP); Plug-and-Play (18510/UDP); Hawk services (18507/UDP); Management (18519/TCP); Cold restart (18512/UDP); SIS communications (12345/TCP); and Wireless Gateway Protocol (18515/UDP). None of these protocols have any authentication features, allowing any attacker capable of communicating with the ports in question to invoke (a subset of) desired functionality. | |||||
CVE-2022-29952 | 1 Bakerhughes | 8 Bently Nevada 3701\/40, Bently Nevada 3701\/40 Firmware, Bently Nevada 3701\/44 and 5 more | 2024-11-21 | N/A | 9.1 CRITICAL |
Bently Nevada condition monitoring equipment through 2022-04-29 mishandles authentication. It utilizes the TDI command and data protocols (60005/TCP, 60007/TCP) for communications between the monitoring controller and System 1 and/or Bently Nevada Monitor Configuration (BNMC) software. These protocols provide configuration management and historical data related functionality. Neither protocol has any authentication features, allowing any attacker capable of communicating with the ports in question to invoke (a subset of) desired functionality. | |||||
CVE-2022-29951 | 1 Jtekt | 34 Nano 10gx Tuc-1157, Nano 10gx Tuc-1157 Firmware, Nano Cpu Tuc-6941 and 31 more | 2024-11-21 | N/A | 9.1 CRITICAL |
JTEKT TOYOPUC PLCs through 2022-04-29 mishandle authentication. They utilize the CMPLink/TCP protocol (configurable on ports 1024-65534 on either TCP or UDP) for a wide variety of engineering purposes such as starting and stopping the PLC, downloading and uploading projects, and changing configuration settings. This protocol does not have any authentication features, allowing any attacker capable of communicating with the port in question to invoke (a subset of) desired functionality. | |||||
CVE-2022-29934 | 1 Usu | 1 Oracle Optimization | 2024-11-21 | 7.2 HIGH | 7.8 HIGH |
USU Oracle Optimization before 5.17.5 lacks Polkit authentication, which allows smartcollector users to achieve root access via pkexec. NOTE: this is not an Oracle Corporation product. | |||||
CVE-2022-29883 | 1 Siemens | 72 7kg8500-0aa00-0aa0, 7kg8500-0aa00-0aa0 Firmware, 7kg8500-0aa00-2aa0 and 69 more | 2024-11-21 | 5.0 MEDIUM | 5.3 MEDIUM |
A vulnerability has been identified in SICAM P850 (All versions < V3.00), SICAM P850 (All versions < V3.00), SICAM P850 (All versions < V3.00), SICAM P850 (All versions < V3.00), SICAM P850 (All versions < V3.00), SICAM P850 (All versions < V3.00), SICAM P850 (All versions < V3.00), SICAM P850 (All versions < V3.00), SICAM P850 (All versions < V3.00), SICAM P850 (All versions < V3.00), SICAM P850 (All versions < V3.00), SICAM P850 (All versions < V3.00), SICAM P850 (All versions < V3.00), SICAM P850 (All versions < V3.00), SICAM P850 (All versions < V3.00), SICAM P850 (All versions < V3.00), SICAM P850 (All versions < V3.00), SICAM P850 (All versions < V3.00), SICAM P855 (All versions < V3.00), SICAM P855 (All versions < V3.00), SICAM P855 (All versions < V3.00), SICAM P855 (All versions < V3.00), SICAM P855 (All versions < V3.00), SICAM P855 (All versions < V3.00), SICAM P855 (All versions < V3.00), SICAM P855 (All versions < V3.00), SICAM P855 (All versions < V3.00), SICAM P855 (All versions < V3.00), SICAM P855 (All versions < V3.00), SICAM P855 (All versions < V3.00), SICAM P855 (All versions < V3.00), SICAM P855 (All versions < V3.00), SICAM P855 (All versions < V3.00), SICAM P855 (All versions < V3.00), SICAM P855 (All versions < V3.00), SICAM P855 (All versions < V3.00). Affected devices do not restrict unauthenticated access to certain pages of the web interface. This could allow an attacker to delete log files without authentication. | |||||
CVE-2022-29881 | 1 Siemens | 72 7kg8500-0aa00-0aa0, 7kg8500-0aa00-0aa0 Firmware, 7kg8500-0aa00-2aa0 and 69 more | 2024-11-21 | 5.0 MEDIUM | 5.3 MEDIUM |
A vulnerability has been identified in SICAM P850 (All versions < V3.00), SICAM P850 (All versions < V3.00), SICAM P850 (All versions < V3.00), SICAM P850 (All versions < V3.00), SICAM P850 (All versions < V3.00), SICAM P850 (All versions < V3.00), SICAM P850 (All versions < V3.00), SICAM P850 (All versions < V3.00), SICAM P850 (All versions < V3.00), SICAM P850 (All versions < V3.00), SICAM P850 (All versions < V3.00), SICAM P850 (All versions < V3.00), SICAM P850 (All versions < V3.00), SICAM P850 (All versions < V3.00), SICAM P850 (All versions < V3.00), SICAM P850 (All versions < V3.00), SICAM P850 (All versions < V3.00), SICAM P850 (All versions < V3.00), SICAM P855 (All versions < V3.00), SICAM P855 (All versions < V3.00), SICAM P855 (All versions < V3.00), SICAM P855 (All versions < V3.00), SICAM P855 (All versions < V3.00), SICAM P855 (All versions < V3.00), SICAM P855 (All versions < V3.00), SICAM P855 (All versions < V3.00), SICAM P855 (All versions < V3.00), SICAM P855 (All versions < V3.00), SICAM P855 (All versions < V3.00), SICAM P855 (All versions < V3.00), SICAM P855 (All versions < V3.00), SICAM P855 (All versions < V3.00), SICAM P855 (All versions < V3.00), SICAM P855 (All versions < V3.00), SICAM P855 (All versions < V3.00), SICAM P855 (All versions < V3.00). The web based management interface of affected devices does not employ special access protection for certain internal developer views. This could allow unauthenticated users to extract internal configuration details. |