Total
8 CVE
CVE | Vendors | Products | Updated | CVSS v2 | CVSS v3 |
---|---|---|---|---|---|
CVE-2024-0995 | 1 Tenda | 2 W6, W6 Firmware | 2024-11-21 | 8.3 HIGH | 7.2 HIGH |
A vulnerability was found in Tenda W6 1.0.0.9(4122). It has been rated as critical. Affected by this issue is the function formwrlSSIDset of the file /goform/wifiSSIDset of the component httpd. The manipulation of the argument index leads to stack-based buffer overflow. The attack may be launched remotely. The exploit has been disclosed to the public and may be used. The identifier of this vulnerability is VDB-252260. NOTE: The vendor was contacted early about this disclosure but did not respond in any way. | |||||
CVE-2024-0994 | 1 Tenda | 2 W6, W6 Firmware | 2024-11-21 | 8.3 HIGH | 7.2 HIGH |
A vulnerability was found in Tenda W6 1.0.0.9(4122). It has been declared as critical. Affected by this vulnerability is the function formSetCfm of the file /goform/setcfm of the component httpd. The manipulation of the argument funcpara1 leads to stack-based buffer overflow. The attack can be launched remotely. The exploit has been disclosed to the public and may be used. The associated identifier of this vulnerability is VDB-252259. NOTE: The vendor was contacted early about this disclosure but did not respond in any way. | |||||
CVE-2022-35561 | 1 Tenda | 2 W6, W6 Firmware | 2024-11-21 | N/A | 7.5 HIGH |
A stack overflow vulnerability exists in /goform/WifiMacFilterSet in Tenda W6 V1.0.0.9(4122) version, which can be exploited by attackers to cause a denial of service (DoS) via the index parameter. | |||||
CVE-2022-35560 | 1 Tenda | 2 W6, W6 Firmware | 2024-11-21 | N/A | 7.5 HIGH |
A stack overflow vulnerability exists in /goform/wifiSSIDset in Tenda W6 V1.0.0.9(4122) version, which can be exploited by attackers to cause a denial of service (DoS) via the index parameter. | |||||
CVE-2022-35559 | 1 Tenda | 2 W6, W6 Firmware | 2024-11-21 | N/A | 9.8 CRITICAL |
A stack overflow vulnerability exists in /goform/setAutoPing in Tenda W6 V1.0.0.9(4122), which allows an attacker to construct ping1 parameters and ping2 parameters for a stack overflow attack. An attacker can use this vulnerability to execute arbitrary code execution. | |||||
CVE-2022-35558 | 1 Tenda | 2 W6, W6 Firmware | 2024-11-21 | N/A | 7.5 HIGH |
A stack overflow vulnerability exists in /goform/WifiMacFilterGet in Tenda W6 V1.0.0.9(4122) version, which can be exploited by attackers to cause a denial of service (DoS) via the index parameter. | |||||
CVE-2022-35557 | 1 Tenda | 2 W6, W6 Firmware | 2024-11-21 | N/A | 7.5 HIGH |
A stack overflow vulnerability exists in /goform/wifiSSIDget in Tenda W6 V1.0.0.9(4122) version, which can be exploited by attackers to cause a denial of service (DoS) via the index parameter. | |||||
CVE-2022-35555 | 1 Tenda | 2 W6, W6 Firmware | 2024-11-21 | N/A | 9.8 CRITICAL |
A command injection vulnerability exists in /goform/exeCommand in Tenda W6 V1.0.0.9(4122), which allows attackers to construct cmdinput parameters for arbitrary command execution. |