Vulnerabilities (CVE)

Filtered by vendor Siemens Subscribe
Filtered by product Sinema Remote Connect Server
Total 60 CVE
CVE Vendors Products Updated CVSS v2 CVSS v3
CVE-2024-39570 1 Siemens 1 Sinema Remote Connect Server 2024-09-06 N/A 8.8 HIGH
A vulnerability has been identified in SINEMA Remote Connect Server (All versions < V3.2 HF1). Affected applications are vulnerable to command injection due to missing server side input sanitation when loading VxLAN configurations. This could allow an authenticated attacker to execute arbitrary code with root privileges.
CVE-2024-39571 1 Siemens 1 Sinema Remote Connect Server 2024-09-06 N/A 8.8 HIGH
A vulnerability has been identified in SINEMA Remote Connect Server (All versions < V3.2 HF1). Affected applications are vulnerable to command injection due to missing server side input sanitation when loading SNMP configurations. This could allow an attacker with the right to modify the SNMP configuration to execute arbitrary code with root privileges.
CVE-2024-39871 1 Siemens 1 Sinema Remote Connect Server 2024-09-06 N/A 5.4 MEDIUM
A vulnerability has been identified in SINEMA Remote Connect Server (All versions < V3.2 SP1). Affected applications do not properly separate the rights to edit device settings and to edit settings for communication relations. This could allow an authenticated attacker with the permission to manage devices to gain access to participant groups that the attacked does not belong to.
CVE-2024-39876 1 Siemens 1 Sinema Remote Connect Server 2024-08-07 N/A 4.0 MEDIUM
A vulnerability has been identified in SINEMA Remote Connect Server (All versions < V3.2 SP1). Affected applications do not properly handle log rotation. This could allow an unauthenticated remote attacker to cause a denial of service condition through resource exhaustion on the device.
CVE-2024-39875 1 Siemens 1 Sinema Remote Connect Server 2024-08-07 N/A 4.3 MEDIUM
A vulnerability has been identified in SINEMA Remote Connect Server (All versions < V3.2 SP1). The affected application allows authenticated, low privilege users with the 'Manage own remote connections' permission to retrieve details about other users and group memberships.
CVE-2021-40438 9 Apache, Broadcom, Debian and 6 more 18 Http Server, Brocade Fabric Operating System Firmware, Debian Linux and 15 more 2024-07-24 6.8 MEDIUM 9.0 CRITICAL
A crafted request uri-path can cause mod_proxy to forward the request to an origin server choosen by the remote user. This issue affects Apache HTTP Server 2.4.48 and earlier.
CVE-2022-32262 1 Siemens 1 Sinema Remote Connect Server 2024-07-09 7.5 HIGH 9.8 CRITICAL
A vulnerability has been identified in SINEMA Remote Connect Server (All versions < V3.1). The affected application contains a file upload server that is vulnerable to command injection. An attacker could use this to achieve arbitrary code execution.
CVE-2022-32261 1 Siemens 1 Sinema Remote Connect Server 2024-07-09 5.0 MEDIUM 7.5 HIGH
A vulnerability has been identified in SINEMA Remote Connect Server (All versions < V3.1). The affected application contains a misconfiguration in the APT update. This could allow an attacker to add insecure packages to the application.
CVE-2022-32260 1 Siemens 1 Sinema Remote Connect Server 2024-07-09 7.5 HIGH 9.8 CRITICAL
A vulnerability has been identified in SINEMA Remote Connect Server (All versions < V3.2 SP1). The affected application creates temporary user credentials for UMC (User Management Component) users. An attacker could use these temporary credentials for authentication bypass in certain scenarios.
CVE-2022-32259 1 Siemens 1 Sinema Remote Connect Server 2024-07-09 6.4 MEDIUM 6.5 MEDIUM
A vulnerability has been identified in SINEMA Remote Connect Server (All versions < V3.1). The system images for installation or update of the affected application contain unit test scripts with sensitive information. An attacker could gain information about testing architecture and also tamper with test configuration.
CVE-2022-32258 1 Siemens 1 Sinema Remote Connect Server 2024-07-09 5.0 MEDIUM 7.5 HIGH
A vulnerability has been identified in SINEMA Remote Connect Server (All versions < V3.1). The affected application contains an older feature that allows to import device configurations via a specific endpoint. An attacker could use this vulnerability for information disclosure.
CVE-2022-32256 1 Siemens 1 Sinema Remote Connect Server 2024-07-09 4.0 MEDIUM 6.5 MEDIUM
A vulnerability has been identified in SINEMA Remote Connect Server (All versions < V3.1). The affected application consists of a web service that lacks proper access control for some of the endpoints. This could lead to low privileged users accessing privileged information.
CVE-2022-32255 1 Siemens 1 Sinema Remote Connect Server 2024-07-09 5.0 MEDIUM 5.3 MEDIUM
A vulnerability has been identified in SINEMA Remote Connect Server (All versions < V3.1). The affected application consists of a web service that lacks proper access control for some of the endpoints. This could lead to unauthorized access to limited information.
CVE-2022-32254 1 Siemens 1 Sinema Remote Connect Server 2024-07-09 5.0 MEDIUM 7.5 HIGH
A vulnerability has been identified in SINEMA Remote Connect Server (All versions < V3.1). A customized HTTP POST request could force the application to write the status of a given user to a log file, exposing sensitive user information that could provide valuable guidance to an attacker.
CVE-2022-32253 1 Siemens 1 Sinema Remote Connect Server 2024-07-09 5.0 MEDIUM 7.5 HIGH
A vulnerability has been identified in SINEMA Remote Connect Server (All versions < V3.1). Due to improper input validation, the OpenSSL certificate's password could be printed to a file reachable by an attacker.
CVE-2022-32252 1 Siemens 1 Sinema Remote Connect Server 2024-07-09 9.3 HIGH 7.8 HIGH
A vulnerability has been identified in SINEMA Remote Connect Server (All versions < V3.1). The application does not perform the integrity check of the update packages. Without validation, an admin user might be tricked to install a malicious package, granting root privileges to an attacker.
CVE-2022-32251 1 Siemens 1 Sinema Remote Connect Server 2024-07-09 7.5 HIGH 9.8 CRITICAL
A vulnerability has been identified in SINEMA Remote Connect Server (All versions < V3.1). There is a missing authentication verification for a resource used to change the roles and permissions of a user. This could allow an attacker to change the permissions of any user and gain the privileges of an administrative user.
CVE-2022-29034 1 Siemens 1 Sinema Remote Connect Server 2024-07-09 4.3 MEDIUM 6.1 MEDIUM
A vulnerability has been identified in SINEMA Remote Connect Server (All versions < V3.1). An error message pop up window in the web interface of the affected application does not prevent injection of JavaScript code. This could allow attackers to perform reflected cross-site scripting (XSS) attacks.
CVE-2022-27221 1 Siemens 1 Sinema Remote Connect Server 2024-07-09 4.3 MEDIUM 5.9 MEDIUM
A vulnerability has been identified in SINEMA Remote Connect Server (All versions < V3.1). An attacker in machine-in-the-middle could obtain plaintext secret values by observing length differences during a series of guesses in which a string in an HTTP request URL potentially matches an unknown string in an HTTP response body, aka a "BREACH" attack.
CVE-2021-22924 7 Debian, Fedoraproject, Haxx and 4 more 53 Debian Linux, Fedora, Libcurl and 50 more 2024-03-27 4.3 MEDIUM 3.7 LOW
libcurl keeps previously used connections in a connection pool for subsequenttransfers to reuse, if one of them matches the setup.Due to errors in the logic, the config matching function did not take 'issuercert' into account and it compared the involved paths *case insensitively*,which could lead to libcurl reusing wrong connections.File paths are, or can be, case sensitive on many systems but not all, and caneven vary depending on used file systems.The comparison also didn't include the 'issuer cert' which a transfer can setto qualify how to verify the server certificate.