Vulnerabilities (CVE)

Filtered by vendor Siemens Subscribe
Filtered by product Siclock Tc100
Total 6 CVE
CVE Vendors Products Updated CVSS v2 CVSS v3
CVE-2018-4856 1 Siemens 4 Siclock Tc100, Siclock Tc100 Firmware, Siclock Tc400 and 1 more 2024-11-21 4.0 MEDIUM 4.9 MEDIUM
A vulnerability has been identified in SICLOCK TC100 (All versions) and SICLOCK TC400 (All versions). An attacker with administrative access to the device's management interface could lock out legitimate users. Manual interaction is required to restore the access of legitimate users.
CVE-2018-4855 1 Siemens 4 Siclock Tc100, Siclock Tc100 Firmware, Siclock Tc400 and 1 more 2024-11-21 4.3 MEDIUM 6.5 MEDIUM
A vulnerability has been identified in SICLOCK TC100 (All versions) and SICLOCK TC400 (All versions). Unencrypted storage of passwords in the client configuration files and during network transmission could allow an attacker in a privileged position to obtain access passwords.
CVE-2018-4854 1 Siemens 4 Siclock Tc100, Siclock Tc100 Firmware, Siclock Tc400 and 1 more 2024-11-21 9.3 HIGH 8.8 HIGH
A vulnerability has been identified in SICLOCK TC100 (All versions) and SICLOCK TC400 (All versions). An attacker with network access to port 69/udp could modify the administrative client stored on the device. If a legitimate user downloads and executes the modified client from the affected device, then he/she could obtain code execution on the client system.
CVE-2018-4853 1 Siemens 4 Siclock Tc100, Siclock Tc100 Firmware, Siclock Tc400 and 1 more 2024-11-21 10.0 HIGH 9.8 CRITICAL
A vulnerability has been identified in SICLOCK TC100 (All versions) and SICLOCK TC400 (All versions). An attacker with network access to port 69/udp could modify the firmware of the device.
CVE-2018-4852 1 Siemens 4 Siclock Tc100, Siclock Tc100 Firmware, Siclock Tc400 and 1 more 2024-11-21 7.5 HIGH 9.8 CRITICAL
A vulnerability has been identified in SICLOCK TC100 (All versions) and SICLOCK TC400 (All versions). An attacker with network access to the device could potentially circumvent the authentication mechanism if he/she is able to obtain certain knowledge specific to the attacked device.
CVE-2018-4851 1 Siemens 4 Siclock Tc100, Siclock Tc100 Firmware, Siclock Tc400 and 1 more 2024-11-21 8.5 HIGH 8.2 HIGH
A vulnerability has been identified in SICLOCK TC100 (All versions) and SICLOCK TC400 (All versions). An attacker with network access to the device could cause a Denial-of-Service condition by sending certain packets to the device, causing potential reboots of the device. The core functionality of the device could be impacted. The time serving functionality recovers when time synchronization with GPS devices or other NTP servers are completed.