CVE-2019-7232 1 Abb 2 Pb610 Panel Builder 600, Pb610 Panel Builder 600 Firmware 2024-11-21 5.8 MEDIUM 8.8 HIGH
The ABB IDAL HTTP server is vulnerable to a buffer overflow when a long Host header is sent in a web request. The Host header value overflows a buffer and overwrites a Structured Exception Handler (SEH) address. An unauthenticated attacker can submit a Host header value of 2047 bytes or more to overflow the buffer and overwrite the SEH address, which can then be leveraged to execute attacker-controlled code on the server.
CVE-2019-7231 1 Abb 2 Pb610 Panel Builder 600, Pb610 Panel Builder 600 Firmware 2024-11-21 2.7 LOW 5.7 MEDIUM
The ABB IDAL FTP server is vulnerable to a buffer overflow when a long string is sent by an authenticated attacker. This overflow is handled, but terminates the process. An authenticated attacker can send a FTP command string of 472 bytes or more to overflow a buffer, causing an exception that terminates the server.
CVE-2019-7230 1 Abb 2 Pb610 Panel Builder 600, Pb610 Panel Builder 600 Firmware 2024-11-21 5.8 MEDIUM 8.8 HIGH
The ABB IDAL FTP server mishandles format strings in a username during the authentication process. Attempting to authenticate with the username %s%p%x%d will crash the server. Sending %08x.AAAA.%08x.%08x will log memory content from the stack.
CVE-2019-7228 1 Abb 2 Pb610 Panel Builder 600, Pb610 Panel Builder 600 Firmware 2024-11-21 5.8 MEDIUM 8.8 HIGH
The ABB IDAL HTTP server mishandles format strings in a username or cookie during the authentication process. Attempting to authenticate with the username %25s%25p%25x%25n will crash the server. Sending %08x.AAAA.%08x.%08x will log memory content from the stack.
CVE-2019-7227 1 Abb 2 Pb610 Panel Builder 600, Pb610 Panel Builder 600 Firmware 2024-11-21 4.1 MEDIUM 7.3 HIGH
In the ABB IDAL FTP server, an authenticated attacker can traverse to arbitrary directories on the hard disk with "CWD ../" and then use the FTP server functionality to download and upload files. An unauthenticated attacker can take advantage of the hardcoded or default credential pair exor/exor to become an authenticated attacker.
CVE-2019-7226 1 Abb 2 Pb610 Panel Builder 600, Pb610 Panel Builder 600 Firmware 2024-11-21 5.8 MEDIUM 8.8 HIGH
The ABB IDAL HTTP server CGI interface contains a URL that allows an unauthenticated attacker to bypass authentication and gain access to privileged functions. Specifically, /cgi/loginDefaultUser creates a session in an authenticated state and returns the session ID along with what may be the username and cleartext password of the user. An attacker can then supply an IDALToken value in a cookie, which will allow them to perform privileged operations such as restarting the service with /cgi/restart. A GET request to /cgi/loginDefaultUser may result in "1 #S_OK IDALToken=532c8632b86694f0232a68a0897a145c admin admin" or a similar response.
CVE-2019-18997 1 Abb 1 Pb610 Panel Builder 600 2024-11-21 5.0 MEDIUM 4.3 MEDIUM
The HMISimulator component of ABB PB610 Panel Builder 600 uses the readFile/writeFile interface to manipulate the work file. Path configuration in PB610 HMISimulator versions 2.8.0.424 and earlier potentially allows access to files outside of the working directory, thus potentially supporting unauthorized file access.
CVE-2019-18996 1 Abb 1 Pb610 Panel Builder 600 2024-11-21 4.4 MEDIUM 7.1 HIGH
Path settings in HMIStudio component of ABB PB610 Panel Builder 600 versions 2.8.0.424 and earlier accept DLLs outside of the program directory, potentially allowing an attacker with access to the local file system the execution of code in the application’s context.
CVE-2019-18995 1 Abb 1 Pb610 Panel Builder 600 2024-11-21 5.0 MEDIUM 4.3 MEDIUM
The HMISimulator component of ABB PB610 Panel Builder 600 versions 2.8.0.424 and earlier fails to validate the content-length field for HTTP requests, exposing HMISimulator to denial of service via crafted HTTP requests manipulating the content-length setting.
CVE-2019-18994 1 Abb 1 Pb610 Panel Builder 600 2024-11-21 3.5 LOW 3.9 LOW
Due to a lack of file length check, the HMIStudio component of ABB PB610 Panel Builder 600 versions 2.8.0.424 and earlier crashes when trying to load an empty *.JPR application file. An attacker with access to the file system might be able to cause application malfunction such as denial of service.