Total
6 CVE
CVE | Vendors | Products | Updated | CVSS v2 | CVSS v3 |
---|---|---|---|---|---|
CVE-2018-5455 | 1 Moxa | 8 Oncell G3110-hspa, Oncell G3110-hspa-t, Oncell G3110-hspa-t Firmware and 5 more | 2024-11-21 | 7.5 HIGH | 9.8 CRITICAL |
A Reliance on Cookies without Validation and Integrity Checking issue was discovered in Moxa OnCell G3100-HSPA Series version 1.4 Build 16062919 and prior. The application allows a cookie parameter to consist of only digits, allowing an attacker to perform a brute force attack bypassing authentication and gaining access to device functions. | |||||
CVE-2018-5453 | 1 Moxa | 8 Oncell G3110-hspa, Oncell G3110-hspa-t, Oncell G3110-hspa-t Firmware and 5 more | 2024-11-21 | 7.8 HIGH | 7.5 HIGH |
An Improper Handling of Length Parameter Inconsistency issue was discovered in Moxa OnCell G3100-HSPA Series version 1.4 Build 16062919 and prior. An attacker may be able to edit the element of an HTTP request, causing the device to become unavailable. | |||||
CVE-2018-5449 | 1 Moxa | 8 Oncell G3110-hspa, Oncell G3110-hspa-t, Oncell G3110-hspa-t Firmware and 5 more | 2024-11-21 | 3.3 LOW | 6.5 MEDIUM |
A NULL Pointer Dereference issue was discovered in Moxa OnCell G3100-HSPA Series version 1.4 Build 16062919 and prior. The application does not check for a NULL value, allowing for an attacker to perform a denial of service attack. | |||||
CVE-2017-7917 | 1 Moxa | 12 Oncell 5004-hspa, Oncell 5004-hspa Firmware, Oncell 5104-hsdpa and 9 more | 2024-11-21 | 6.8 MEDIUM | 8.8 HIGH |
A Cross-Site Request Forgery issue was discovered in Moxa OnCell G3110-HSPA Version 1.3 build 15082117 and previous versions, OnCell G3110-HSDPA Version 1.2 Build 09123015 and previous versions, OnCell G3150-HSDPA Version 1.4 Build 11051315 and previous versions, OnCell 5104-HSDPA, OnCell 5104-HSPA, and OnCell 5004-HSPA. The application does not sufficiently verify if a request was intentionally provided by the user who submitted the request, which could allow an attacker to modify the configuration of the device. | |||||
CVE-2017-7915 | 1 Moxa | 12 Oncell 5004-hspa, Oncell 5004-hspa Firmware, Oncell 5104-hsdpa and 9 more | 2024-11-21 | 7.5 HIGH | 9.8 CRITICAL |
An Improper Restriction of Excessive Authentication Attempts issue was discovered in Moxa OnCell G3110-HSPA Version 1.3 build 15082117 and previous versions, OnCell G3110-HSDPA Version 1.2 Build 09123015 and previous versions, OnCell G3150-HSDPA Version 1.4 Build 11051315 and previous versions, OnCell 5104-HSDPA, OnCell 5104-HSPA, and OnCell 5004-HSPA. An attacker can freely use brute force to determine parameters needed to bypass authentication. | |||||
CVE-2017-7913 | 1 Moxa | 12 Oncell 5004-hspa, Oncell 5004-hspa Firmware, Oncell 5104-hsdpa and 9 more | 2024-11-21 | 5.0 MEDIUM | 9.8 CRITICAL |
A Plaintext Storage of a Password issue was discovered in Moxa OnCell G3110-HSPA Version 1.3 build 15082117 and previous versions, OnCell G3110-HSDPA Version 1.2 Build 09123015 and previous versions, OnCell G3150-HSDPA Version 1.4 Build 11051315 and previous versions, OnCell 5104-HSDPA, OnCell 5104-HSPA, and OnCell 5004-HSPA. The application's configuration file contains parameters that represent passwords in plaintext. |