Vulnerabilities (CVE)

Filtered by vendor Sick Subscribe
Filtered by product Msc800 Firmware
Total 3 CVE
CVE Vendors Products Updated CVSS v2 CVSS v3
CVE-2022-27577 1 Sick 2 Msc800, Msc800 Firmware 2024-11-21 6.4 MEDIUM 9.1 CRITICAL
The vulnerability in the MSC800 in all versions before 4.15 allows for an attacker to predict the TCP initial sequence number. When the TCP sequence is predictable, an attacker can send packets that are forged to appear to come from a trusted computer. These forged packets could compromise services on the MSC800. SICK has released a new firmware version of the SICK MSC800 and recommends updating to the newest version.
CVE-2020-2075 1 Sick 60 Clv620, Clv620 Firmware, Clv621 and 57 more 2024-11-21 5.0 MEDIUM 7.5 HIGH
Platform mechanism AutoIP allows remote attackers to reboot the device via a crafted packet in SICK AG solutions Bulkscan LMS111, Bulkscan LMS511, CLV62x – CLV65x, ICR890-3, LMS10x, LMS11x, LMS15x, LMS12x, LMS13x, LMS14x, LMS5xx, LMS53x, MSC800, RFH.
CVE-2019-10979 1 Sick 2 Msc800, Msc800 Firmware 2024-11-21 7.5 HIGH 9.8 CRITICAL
SICK MSC800 all versions prior to Version 4.0, the affected firmware versions contain a hard-coded customer account password.