Vulnerabilities (CVE)

Filtered by vendor Tenda Subscribe
Filtered by product Fh1203 Firmware
Total 13 CVE
CVE Vendors Products Updated CVSS v2 CVSS v3
CVE-2023-38940 1 Tenda 6 F1203, F1203 Firmware, Fh1203 and 3 more 2024-11-21 N/A 9.8 CRITICAL
Tenda F1203 V2.0.1.6, FH1203 V2.0.1.6 and FH1205 V2.0.0.7(775) were discovered to contain a stack overflow via the ssid parameter in the form_fast_setting_wifi_set function.
CVE-2023-38936 1 Tenda 18 Ac10, Ac10 Firmware, Ac1206 and 15 more 2024-11-21 N/A 9.8 CRITICAL
Tenda AC10 V1.0 V15.03.06.23, AC1206 V15.03.06.23, AC6 V2.0 V15.03.06.23, AC7 V1.0 V15.03.06.44, AC5 V1.0 V15.03.06.28, FH1203 V2.0.1.6, AC9 V3.0 V15.03.06.42_multi and FH1205 V2.0.0.7(775) were discovered to contain a stack overflow via the speed_dir parameter in the formSetSpeedWan function.
CVE-2023-38934 1 Tenda 6 F1203, F1203 Firmware, Fh1203 and 3 more 2024-11-21 N/A 9.8 CRITICAL
Tenda F1203 V2.0.1.6, FH1203 V2.0.1.6 and FH1205 V2.0.0.7(775) was discovered to contain a stack overflow via the deviceId parameter in the formSetDeviceName function.
CVE-2023-38933 1 Tenda 18 Ac10, Ac10 Firmware, Ac1206 and 15 more 2024-11-21 N/A 9.8 CRITICAL
Tenda AC6 V2.0 V15.03.06.23, AC7 V1.0 V15.03.06.44, F1203 V2.0.1.6, AC5 V1.0 V15.03.06.28, FH1203 V2.0.1.6 and AC9 V3.0 V15.03.06.42_multi, and FH1205 V2.0.0.7(775) were discovered to contain a stack overflow via the deviceId parameter in the formSetClientState function.
CVE-2023-38931 1 Tenda 16 Ac10, Ac10 Firmware, Ac1206 and 13 more 2024-11-21 N/A 9.8 CRITICAL
Tenda AC10 V1.0 V15.03.06.23, AC1206 V15.03.06.23, AC8 v4 V16.03.34.06, AC6 V2.0 V15.03.06.23, AC7 V1.0 V15.03.06.44, F1203 V2.0.1.6, AC5 V1.0 V15.03.06.28, AC10 v4.0 V16.03.10.13 and FH1203 V2.0.1.6 were discovered to contain a stack overflow via the list parameter in the setaccount function.
CVE-2023-37707 1 Tenda 2 Fh1203, Fh1203 Firmware 2024-11-21 N/A 9.8 CRITICAL
Tenda FH1203 V2.0.1.6 was discovered to contain a stack overflow via the page parameter in the fromVirtualSer function.
CVE-2023-37706 1 Tenda 2 Fh1203, Fh1203 Firmware 2024-11-21 N/A 9.8 CRITICAL
Tenda FH1203 V2.0.1.6 was discovered to contain a stack overflow via the entrys parameter in the fromAddressNat function.
CVE-2023-37705 1 Tenda 2 Fh1203, Fh1203 Firmware 2024-11-21 N/A 9.8 CRITICAL
Tenda FH1203 V2.0.1.6 was discovered to contain a stack overflow via the page parameter in the fromAddressNat function.
CVE-2023-37704 1 Tenda 2 Fh1203, Fh1203 Firmware 2024-11-21 N/A 9.8 CRITICAL
Tenda FH1203 V2.0.1.6 was discovered to contain a stack overflow via the deviceId parameter in the formSetClientState function.
CVE-2023-37703 1 Tenda 2 Fh1203, Fh1203 Firmware 2024-11-21 N/A 9.8 CRITICAL
Tenda FH1203 V2.0.1.6 was discovered to contain a stack overflow via the speed_dir parameter in the formSetSpeedWan function.
CVE-2023-37702 1 Tenda 2 Fh1203, Fh1203 Firmware 2024-11-21 N/A 9.8 CRITICAL
Tenda FH1203 V2.0.1.6 was discovered to contain a stack overflow via the deviceId parameter in the formSetDeviceName function.
CVE-2023-37701 1 Tenda 2 Fh1203, Fh1203 Firmware 2024-11-21 N/A 9.8 CRITICAL
Tenda FH1203 V2.0.1.6 was discovered to contain a stack overflow via the deviceId parameter in the addWifiMacFilter function.
CVE-2023-37700 1 Tenda 2 Fh1203, Fh1203 Firmware 2024-11-21 N/A 9.8 CRITICAL
Tenda FH1203 V2.0.1.6 was discovered to contain a stack overflow via the ssid parameter in the form_fast_setting_wifi_set function.