Vulnerabilities (CVE)

Filtered by vendor Tenda Subscribe
Filtered by product Fh1201 Firmware
Total 11 CVE
CVE Vendors Products Updated CVSS v2 CVSS v3
CVE-2024-42947 1 Tenda 2 Fh1201, Fh1201 Firmware 2024-09-06 N/A 9.8 CRITICAL
An issue in the handler function in /goform/telnet of Tenda FH1201 v1.2.0.14 (408) allows attackers to execute arbitrary commands via a crafted HTTP request.
CVE-2024-42941 1 Tenda 2 Fh1201, Fh1201 Firmware 2024-09-03 N/A 7.5 HIGH
Tenda FH1201 v1.2.0.14 (408) was discovered to contain a stack overflow via the wanmode parameter in the fromAdvSetWan function. This vulnerability allows attackers to cause a Denial of Service (DoS) via a crafted POST request.
CVE-2024-42940 1 Tenda 2 Fh1201, Fh1201 Firmware 2024-09-03 N/A 7.5 HIGH
Tenda FH1201 v1.2.0.14 (408) was discovered to contain a stack overflow via the page parameter in the fromP2pListFilter function. This vulnerability allows attackers to cause a Denial of Service (DoS) via a crafted POST request.
CVE-2024-42948 1 Tenda 2 Fh1201, Fh1201 Firmware 2024-09-03 N/A 7.5 HIGH
Tenda FH1201 v1.2.0.14 (408) was discovered to contain a stack overflow via the delno parameter in the fromPptpUserSetting function. This vulnerability allows attackers to cause a Denial of Service (DoS) via a crafted POST request.
CVE-2024-42950 1 Tenda 2 Fh1201, Fh1201 Firmware 2024-08-21 N/A 7.5 HIGH
Tenda FH1201 v1.2.0.14 (408) was discovered to contain a stack overflow via the Go parameter in the fromSafeClientFilter function. This vulnerability allows attackers to cause a Denial of Service (DoS) via a crafted POST request.
CVE-2024-42951 1 Tenda 2 Fh1201, Fh1201 Firmware 2024-08-16 N/A 7.5 HIGH
Tenda FH1201 v1.2.0.14 (408) was discovered to contain a stack overflow via the mit_pptpusrpw parameter in the fromWizardHandle function. This vulnerability allows attackers to cause a Denial of Service (DoS) via a crafted POST request.
CVE-2024-42943 1 Tenda 2 Fh1201, Fh1201 Firmware 2024-08-16 N/A 7.5 HIGH
Tenda FH1201 v1.2.0.14 (408) was discovered to contain a stack overflow via the PPPOEPassword parameter in the fromAdvSetWan function. This vulnerability allows attackers to cause a Denial of Service (DoS) via a crafted POST request.
CVE-2024-42955 1 Tenda 2 Fh1201, Fh1201 Firmware 2024-08-16 N/A 7.5 HIGH
Tenda FH1201 v1.2.0.14 (408) was discovered to contain a stack overflow via the page parameter in the fromSafeClientFilter function. This vulnerability allows attackers to cause a Denial of Service (DoS) via a crafted POST request.
CVE-2024-42946 1 Tenda 2 Fh1201, Fh1201 Firmware 2024-08-16 N/A 7.5 HIGH
Tenda FH1201 v1.2.0.14 (408) was discovered to contain a stack overflow via the page parameter in the fromVirtualSer function. This vulnerability allows attackers to cause a Denial of Service (DoS) via a crafted POST request.
CVE-2024-42944 1 Tenda 2 Fh1201, Fh1201 Firmware 2024-08-15 N/A 7.5 HIGH
Tenda FH1201 v1.2.0.14 (408) was discovered to contain a stack overflow via the page parameter in the fromNatlimit function. This vulnerability allows attackers to cause a Denial of Service (DoS) via a crafted POST request.
CVE-2024-42952 1 Tenda 2 Fh1201, Fh1201 Firmware 2024-08-15 N/A 7.5 HIGH
Tenda FH1201 v1.2.0.14 (408) was discovered to contain a stack overflow via the page parameter in the fromqossetting function. This vulnerability allows attackers to cause a Denial of Service (DoS) via a crafted POST request.