Vulnerabilities (CVE)

Filtered by vendor Barco Subscribe
Filtered by product Clickshare Csc-1
Total 6 CVE
CVE Vendors Products Updated CVSS v2 CVSS v3
CVE-2017-9377 1 Barco 4 Clickshare Csc-1, Clickshare Csc-1 Firmware, Clickshare Csm-1 and 1 more 2024-11-21 9.0 HIGH 8.8 HIGH
A command injection was identified on Barco ClickShare Base Unit devices with CSM-1 firmware before 1.7.0.3 and CSC-1 firmware before 1.10.0.10. An attacker with access to the product's web API can exploit this vulnerability to completely compromise the vulnerable device.
CVE-2017-12460 1 Barco 4 Clickshare Csc-1, Clickshare Csc-1 Firmware, Clickshare Csm-1 and 1 more 2024-11-21 3.5 LOW 5.4 MEDIUM
An issue was discovered in Barco ClickShare CSM-1 firmware before v1.7.0.3 and CSC-1 firmware before v1.10.0.10. An authenticated user can manage the wallpaper collection in the webUI to be shown as background on the ClickShare product. By uploading a wallpaper with a specially crafted name, an HTML injection can be triggered as special characters are not neutralized before output.
CVE-2016-3152 1 Barco 2 Clickshare Csc-1, Clickshare Csc-1 Firmware 2024-11-21 5.0 MEDIUM 9.8 CRITICAL
Barco ClickShare CSC-1 devices with firmware before 01.09.03 allow remote attackers to obtain the root password by downloading and extracting the firmware image.
CVE-2016-3151 1 Barco 6 Clickshare Csc-1, Clickshare Csc-1 Firmware, Clickshare Cse-200 and 3 more 2024-11-21 5.0 MEDIUM 7.5 HIGH
Directory traversal vulnerability in the wallpaper parsing functionality in Barco ClickShare CSC-1 devices with firmware before 01.09.03, CSM-1 devices with firmware before 01.06.02, and CSE-200 devices with firmware before 01.03.02 allows remote attackers to read /etc/shadow via unspecified vectors.
CVE-2016-3150 1 Barco 4 Clickshare Csc-1, Clickshare Csc-1 Firmware, Clickshare Cse-200 and 1 more 2024-11-21 4.3 MEDIUM 6.1 MEDIUM
Cross-site scripting (XSS) vulnerability in wallpaper.php in the Base Unit in Barco ClickShare CSC-1 devices with firmware before 01.09.03, CSM-1 devices with firmware before 01.06.02, and CSE-200 devices with firmware before 01.03.02 allows remote attackers to inject arbitrary web script or HTML via unspecified vectors.
CVE-2016-3149 1 Barco 4 Clickshare Csc-1, Clickshare Csc-1 Firmware, Clickshare Csm-1 and 1 more 2024-11-21 10.0 HIGH 9.8 CRITICAL
Barco ClickShare CSC-1 devices with firmware before 01.09.03 and CSM-1 devices with firmware before 01.06.02 allow remote attackers to execute arbitrary code via unspecified vectors.