CVE-2014-2251 | 1 Siemens | 1 Simatic S7-1500 Cpu Firmware | 2024-11-21 | 8.3 HIGH | N/A |
The random-number generator on Siemens SIMATIC S7-1500 CPU PLC devices with firmware before 1.5.0 does not have sufficient entropy, which makes it easier for remote attackers to defeat cryptographic protection mechanisms and hijack sessions via unspecified vectors. | |||||
CVE-2014-2250 | 1 Siemens | 6 Simatic S7 Cpu-1211c, Simatic S7 Cpu 1200 Firmware, Simatic S7 Cpu 1212c and 3 more | 2024-11-21 | 8.3 HIGH | N/A |
The random-number generator on Siemens SIMATIC S7-1200 CPU PLC devices with firmware before 4.0 does not have sufficient entropy, which makes it easier for remote attackers to defeat cryptographic protection mechanisms and hijack sessions via unspecified vectors, a different vulnerability than CVE-2014-2251. | |||||
CVE-2014-2249 | 1 Siemens | 1 Simatic S7-1500 Cpu Firmware | 2024-11-21 | 5.8 MEDIUM | N/A |
Cross-site request forgery (CSRF) vulnerability on Siemens SIMATIC S7-1500 CPU PLC devices with firmware before 1.5.0 and SIMATIC S7-1200 CPU PLC devices with firmware before 4.0 allows remote attackers to hijack the authentication of unspecified victims via unknown vectors. | |||||
CVE-2014-2248 | 1 Siemens | 1 Simatic S7-1500 Cpu Firmware | 2024-11-21 | 4.3 MEDIUM | N/A |
Open redirect vulnerability in the integrated web server on Siemens SIMATIC S7-1500 CPU PLC devices with firmware before 1.5.0 allows remote attackers to redirect users to arbitrary web sites and conduct phishing attacks via unspecified vectors. | |||||
CVE-2014-2247 | 1 Siemens | 1 Simatic S7-1500 Cpu Firmware | 2024-11-21 | 5.8 MEDIUM | N/A |
The integrated web server on Siemens SIMATIC S7-1500 CPU PLC devices with firmware before 1.5.0 allows remote attackers to inject headers via unspecified vectors. | |||||
CVE-2014-2246 | 1 Siemens | 1 Simatic S7-1500 Cpu Firmware | 2024-11-21 | 4.3 MEDIUM | N/A |
Cross-site scripting (XSS) vulnerability in the integrated web server on Siemens SIMATIC S7-1500 CPU PLC devices with firmware before 1.5.0 allows remote attackers to inject arbitrary web script or HTML via unspecified vectors. | |||||
CVE-2014-1966 | 1 Siemens | 3 Ruggedcom Rs950g, Ruggedcom Rsg2488, Ruggedcom Rugged Operating System | 2024-11-21 | 7.8 HIGH | N/A |
The SNMP implementation in Siemens RuggedCom ROS before 3.11, ROS 3.11 for RS950G, ROS 3.12 before 3.12.4, and ROS 4.0 for RSG2488 allows remote attackers to cause a denial of service (device outage) via crafted packets. | |||||
CVE-2014-1699 | 1 Siemens | 1 Simatic Wincc Open Architecture | 2024-11-21 | 5.0 MEDIUM | N/A |
Siemens SIMATIC WinCC OA before 3.12 P002 January allows remote attackers to cause a denial of service (monitoring-service outage) via malformed HTTP requests to port 4999. | |||||
CVE-2014-1698 | 1 Siemens | 1 Simatic Wincc Open Architecture | 2024-11-21 | 5.0 MEDIUM | N/A |
Directory traversal vulnerability in Siemens SIMATIC WinCC OA before 3.12 P002 January allows remote attackers to read arbitrary files via crafted packets to TCP port 4999. | |||||
CVE-2014-1697 | 1 Siemens | 1 Simatic Wincc Open Architecture | 2024-11-21 | 7.5 HIGH | N/A |
The integrated web server in Siemens SIMATIC WinCC OA before 3.12 P002 January allows remote attackers to execute arbitrary code via crafted packets to TCP port 4999. | |||||
CVE-2014-1696 | 1 Siemens | 1 Simatic Wincc Open Architecture | 2024-11-21 | 5.0 MEDIUM | N/A |
Siemens SIMATIC WinCC OA before 3.12 P002 January uses a weak hash algorithm for passwords, which makes it easier for remote attackers to obtain access via a brute-force attack. | |||||
CVE-2014-0224 | 9 Fedoraproject, Filezilla-project, Mariadb and 6 more | 20 Fedora, Filezilla Server, Mariadb and 17 more | 2024-11-21 | 5.8 MEDIUM | 7.4 HIGH |
OpenSSL before 0.9.8za, 1.0.0 before 1.0.0m, and 1.0.1 before 1.0.1h does not properly restrict processing of ChangeCipherSpec messages, which allows man-in-the-middle attackers to trigger use of a zero-length master key in certain OpenSSL-to-OpenSSL communications, and consequently hijack sessions or obtain sensitive information, via a crafted TLS handshake, aka the "CCS Injection" vulnerability. | |||||
CVE-2014-0160 | 13 Broadcom, Canonical, Debian and 10 more | 35 Symantec Messaging Gateway, Ubuntu Linux, Debian Linux and 32 more | 2024-11-21 | 5.0 MEDIUM | 7.5 HIGH |
The (1) TLS and (2) DTLS implementations in OpenSSL 1.0.1 before 1.0.1g do not properly handle Heartbeat Extension packets, which allows remote attackers to obtain sensitive information from process memory via crafted packets that trigger a buffer over-read, as demonstrated by reading private keys, related to d1_both.c and t1_lib.c, aka the Heartbleed bug. | |||||
CVE-2013-6926 | 1 Siemens | 1 Ruggedcom Rugged Operating System | 2024-11-21 | 8.0 HIGH | N/A |
The integrated HTTPS server in Siemens RuggedCom ROS before 3.12.2 allows remote authenticated users to bypass intended restrictions on administrative actions by leveraging access to a (1) guest or (2) operator account. | |||||
CVE-2013-6925 | 1 Siemens | 1 Ruggedcom Rugged Operating System | 2024-11-21 | 8.3 HIGH | N/A |
The integrated HTTPS server in Siemens RuggedCom ROS before 3.12.2 allows remote attackers to hijack web sessions by predicting a session id value. | |||||
CVE-2013-6920 | 1 Siemens | 14 Sinamics G110, Sinamics G110d, Sinamics G120 and 11 more | 2024-11-21 | 10.0 HIGH | N/A |
Siemens SINAMICS S/G controllers with firmware before 4.6.11 do not require authentication for FTP and TELNET sessions, which allows remote attackers to bypass intended access restrictions via TCP traffic to port (1) 21 or (2) 23. | |||||
CVE-2013-6840 | 1 Siemens | 1 Comos | 2024-11-21 | 6.9 MEDIUM | N/A |
Siemens COMOS before 9.2.0.8.1, 10.0 before 10.0.3.1.40, and 10.1 before 10.1.0.0.2 allows local users to gain database privileges via unspecified vectors. | |||||
CVE-2013-5944 | 1 Siemens | 3 Scalance X-200, Scalance X-200 Series Firmware, Scalance X-200irt | 2024-11-21 | 10.0 HIGH | N/A |
The integrated web server on Siemens SCALANCE X-200 switches with firmware before 4.5.0 and X-200IRT switches with firmware before 5.1.0 does not properly enforce authentication requirements, which allows remote attackers to perform administrative actions via requests to the management interface. | |||||
CVE-2013-5709 | 1 Siemens | 9 Scalance X-200, Scalance X-200 Series Firmware, Scalance X-200rna and 6 more | 2024-11-21 | 8.3 HIGH | N/A |
The authentication implementation in the web server on Siemens SCALANCE X-200 switches with firmware before 5.0.0 does not use a sufficient source of entropy for generating values of random numbers, which makes it easier for remote attackers to hijack sessions by predicting a value. | |||||
CVE-2013-4943 | 1 Siemens | 1 Comos | 2024-11-21 | 7.2 HIGH | N/A |
The client application in Siemens COMOS before 9.1 Update 458, 9.2 before 9.2.0.6.37, and 10.0 before 10.0.3.0.19 allows local users to gain privileges and bypass intended database-operation restrictions by leveraging COMOS project access. |