Vulnerabilities (CVE)

Filtered by vendor Tenda Subscribe
Total 776 CVE
CVE Vendors Products Updated CVSS v2 CVSS v3
CVE-2024-42955 1 Tenda 2 Fh1201, Fh1201 Firmware 2024-08-16 N/A 7.5 HIGH
Tenda FH1201 v1.2.0.14 (408) was discovered to contain a stack overflow via the page parameter in the fromSafeClientFilter function. This vulnerability allows attackers to cause a Denial of Service (DoS) via a crafted POST request.
CVE-2024-42946 1 Tenda 2 Fh1201, Fh1201 Firmware 2024-08-16 N/A 7.5 HIGH
Tenda FH1201 v1.2.0.14 (408) was discovered to contain a stack overflow via the page parameter in the fromVirtualSer function. This vulnerability allows attackers to cause a Denial of Service (DoS) via a crafted POST request.
CVE-2024-42982 1 Tenda 2 Fh1206, Fh1206 Firmware 2024-08-16 N/A 7.5 HIGH
Tenda FH1206 v02.03.01.35 was discovered to contain a stack overflow via the page parameter in the fromVirtualSer function. This vulnerability allows attackers to cause a Denial of Service (DoS) via a crafted POST request.
CVE-2024-42944 1 Tenda 2 Fh1201, Fh1201 Firmware 2024-08-15 N/A 7.5 HIGH
Tenda FH1201 v1.2.0.14 (408) was discovered to contain a stack overflow via the page parameter in the fromNatlimit function. This vulnerability allows attackers to cause a Denial of Service (DoS) via a crafted POST request.
CVE-2024-42952 1 Tenda 2 Fh1201, Fh1201 Firmware 2024-08-15 N/A 7.5 HIGH
Tenda FH1201 v1.2.0.14 (408) was discovered to contain a stack overflow via the page parameter in the fromqossetting function. This vulnerability allows attackers to cause a Denial of Service (DoS) via a crafted POST request.
CVE-2024-7582 1 Tenda 2 I22, I22 Firmware 2024-08-08 9.0 HIGH 9.8 CRITICAL
A vulnerability classified as critical was found in Tenda i22 1.0.0.3(4687). This vulnerability affects the function formApPortalAccessCodeAuth of the file /goform/apPortalAccessCodeAuth. The manipulation of the argument accessCode/data/acceInfo leads to buffer overflow. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
CVE-2024-7583 1 Tenda 2 I22, I22 Firmware 2024-08-08 9.0 HIGH 9.8 CRITICAL
A vulnerability, which was classified as critical, has been found in Tenda i22 1.0.0.3(4687). This issue affects the function formApPortalOneKeyAuth of the file /goform/apPortalOneKeyAuth. The manipulation of the argument data leads to buffer overflow. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
CVE-2024-40414 1 Tenda 2 Ax1806, Ax1806 Firmware 2024-08-07 N/A 9.8 CRITICAL
A vulnerability in /goform/SetNetControlList in the sub_656BC function in Tenda AX1806 1.0.0.1 firmware leads to stack-based buffer overflow.
CVE-2024-40415 1 Tenda 2 Ax1806, Ax1806 Firmware 2024-08-07 N/A 9.8 CRITICAL
A vulnerability in /goform/SetStaticRouteCfg in the sub_519F4 function in Tenda AX1806 1.0.0.1 firmware leads to stack-based buffer overflow.
CVE-2024-40416 1 Tenda 2 Ax1806, Ax1806 Firmware 2024-08-07 N/A 9.8 CRITICAL
A vulnerability in /goform/SetVirtualServerCfg in the sub_6320C function in Tenda AX1806 1.0.0.1 firmware leads to stack-based buffer overflow.
CVE-2024-30620 1 Tenda 2 Ax1803, Ax1803 Firmware 2024-08-01 N/A 9.8 CRITICAL
Tenda AX1803 v1.0.0.1 contains a stack overflow via the serviceName parameter in the function fromAdvSetMacMtuWan.
CVE-2024-28535 1 Tenda 1 Ac18 Firmware 2024-08-01 N/A 9.8 CRITICAL
Tenda AC18 V15.03.05.05 has a stack overflow vulnerability in the mitInterface parameter of fromAddressNat function.
CVE-2023-45481 1 Tenda 2 Ac10, Ac10 Firmware 2024-08-01 N/A 9.8 CRITICAL
Tenda AC10 version US_AC10V4.0si_V16.03.10.13_cn was discovered to contain a stack overflow via the firewallEn parameter in the function SetFirewallCfg.
CVE-2023-38823 1 Tenda 8 Ac18, Ac18 Firmware, Ac19 and 5 more 2024-07-29 N/A 9.8 CRITICAL
Buffer Overflow vulnerability in Tenda Ac19 v.1.0, AC18, AC9 v.1.0, AC6 v.2.0 and v.1.0 allows a remote attacker to execute arbitrary code via the formSetCfm function in bin/httpd.
CVE-2024-6962 1 Tenda 2 O3, O3 Firmware1.0.0.10\(2478\) 2024-07-25 9.0 HIGH 8.8 HIGH
A vulnerability classified as critical was found in Tenda O3 1.0.0.10. This vulnerability affects the function formQosSet. The manipulation of the argument remark/ipRange/upSpeed/downSpeed/enable leads to stack-based buffer overflow. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used. The identifier of this vulnerability is VDB-272116. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
CVE-2024-6963 1 Tenda 2 O3, O3 Firmware1.0.0.10\(2478\) 2024-07-25 9.0 HIGH 8.8 HIGH
A vulnerability, which was classified as critical, has been found in Tenda O3 1.0.0.10. This issue affects the function formexeCommand. The manipulation of the argument cmdinput leads to stack-based buffer overflow. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used. The identifier VDB-272117 was assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
CVE-2024-6964 1 Tenda 2 O3, O3 Firmware1.0.0.10\(2478\) 2024-07-25 9.0 HIGH 8.8 HIGH
A vulnerability, which was classified as critical, was found in Tenda O3 1.0.0.10. Affected is the function fromDhcpSetSer. The manipulation of the argument dhcpEn/startIP/endIP/preDNS/altDNS/mask/gateway leads to stack-based buffer overflow. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used. VDB-272118 is the identifier assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
CVE-2024-6965 1 Tenda 2 O3, O3 Firmware1.0.0.10\(2478\) 2024-07-25 9.0 HIGH 8.8 HIGH
A vulnerability has been found in Tenda O3 1.0.0.10 and classified as critical. Affected by this vulnerability is the function fromVirtualSet. The manipulation of the argument ip/localPort/publicPort/app leads to stack-based buffer overflow. The attack can be launched remotely. The exploit has been disclosed to the public and may be used. The associated identifier of this vulnerability is VDB-272119. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
CVE-2023-48194 1 Tenda 2 Ac8v4, Ac8v4 Firmware 2024-07-12 N/A 9.8 CRITICAL
Vulnerability in Tenda AC8v4 .V16.03.34.09 due to sscanf and the last digit of s8 being overwritten with \x0. After executing set_client_qos, control over the gp register can be obtained.
CVE-2024-2856 1 Tenda 2 Ac10, Ac10 Firmware 2024-05-17 9.0 HIGH 9.8 CRITICAL
A vulnerability, which was classified as critical, has been found in Tenda AC10 16.03.10.13/16.03.10.20. Affected by this issue is the function fromSetSysTime of the file /goform/SetSysTimeCfg. The manipulation of the argument timeZone leads to stack-based buffer overflow. The attack may be launched remotely. The exploit has been disclosed to the public and may be used. The identifier of this vulnerability is VDB-257780. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.