Total
80 CVE
CVE | Vendors | Products | Updated | CVSS v2 | CVSS v3 |
---|---|---|---|---|---|
CVE-2021-0290 | 1 Juniper | 26 Ex9200, Ex9204, Ex9208 and 23 more | 2024-11-21 | 3.3 LOW | 6.5 MEDIUM |
Improper Handling of Exceptional Conditions in Ethernet interface frame processing of Juniper Networks Junos OS allows an attacker to send specially crafted frames over the local Ethernet segment, causing the interface to go into a down state, resulting in a Denial of Service (DoS) condition. The interface does not recover on its own and the FPC must be reset manually. Continued receipt and processing of these frames will create a sustained Denial of Service (DoS) condition. This issue is platform-specific and affects the following platforms and line cards: * MPC7E/8E/9E and MPC10E on MX240, MX480, MX960, MX2008, MX2010, and MX2020 * MX204, MX10003, MX10008, MX10016 * EX9200, EX9251 * SRX4600 No other products or platforms are affected by this vulnerability. An indication of this issue occurring can be seen in the system log messages, as shown below: user@host> show log messages | match "Failed to complete DFE tuning" fpc4 smic_phy_dfe_tuning_state: et-4/1/6 - Failed to complete DFE tuning (count 3) and interface will be in a permanently down state: user@host> show interfaces et-4/1/6 terse Interface Admin Link Proto Local Remote et-4/1/6 up down et-4/1/6.0 up down aenet --> ae101.0 This issue affects Juniper Networks Junos OS: 16.1 versions prior to 16.1R7-S7 on MX Series; 17.1R1 and later versions prior to 17.2R3-S3 on MX Series; 17.3 versions prior to 17.3R3-S8 on MX Series; 17.4 versions prior to 17.4R2-S11, 17.4R3-S1 on MX Series, SRX4600; 18.1 versions prior to 18.1R3-S10 on MX Series, EX9200 Series, SRX4600; 18.2 versions prior to 18.2R3-S3 on MX Series, EX9200 Series, SRX4600; 18.3 versions prior to 18.3R3-S1 on MX Series, EX9200 Series, SRX4600; 18.4 versions prior to 18.4R2-S3, 18.4R3 on MX Series, EX9200 Series, SRX4600; 19.1 versions prior to 19.1R2-S1, 19.1R3 on MX Series, EX9200 Series, SRX4600; 19.2 versions prior to 19.2R1-S3, 19.2R2 on MX Series, EX9200 Series, SRX4600; 19.3 versions prior to 19.3R2 on MX Series, EX9200 Series, SRX4600. This issue does not affect Juniper Networks Junos OS versions prior to 16.1R1. | |||||
CVE-2021-0289 | 1 Juniper | 229 Acx1000, Acx1100, Acx2000 and 226 more | 2024-11-21 | 2.9 LOW | 6.5 MEDIUM |
When user-defined ARP Policer is configured and applied on one or more Aggregated Ethernet (AE) interface units, a Time-of-check Time-of-use (TOCTOU) Race Condition vulnerability between the Device Control Daemon (DCD) and firewall process (dfwd) daemons of Juniper Networks Junos OS allows an attacker to bypass the user-defined ARP Policer. In this particular case the User ARP policer is replaced with default ARP policer. To review the desired ARP Policers and actual state one can run the command "show interfaces <> extensive" and review the output. See further details below. An example output is: show interfaces extensive | match policer Policer: Input: __default_arp_policer__ <<< incorrect if user ARP Policer was applied on an AE interface and the default ARP Policer is displayed Policer: Input: jtac-arp-ae5.317-inet-arp <<< correct if user ARP Policer was applied on an AE interface For all platforms, except SRX Series: This issue affects Juniper Networks Junos OS: All versions 5.6R1 and all later versions prior to 18.4 versions prior to 18.4R2-S9, 18.4R3-S9 with the exception of 15.1 versions 15.1R7-S10 and later versions; 19.4 versions prior to 19.4R3-S3; 20.1 versions prior to 20.1R3; 20.2 versions prior to 20.2R3-S2; 20.3 version 20.3R1 and later versions; 20.4 versions prior to 20.4R3; 21.1 versions prior to 21.1R2; This issue does not affect Juniper Networks Junos OS versions prior to 5.6R1. On SRX Series this issue affects Juniper Networks Junos OS: 18.4 versions prior to 18.4R2-S9, 18.4R3-S9; 19.4 versions prior to 19.4R3-S4; 20.1 versions prior to 20.1R3; 20.2 versions prior to 20.2R3-S2; 20.3 version 20.3R1 and later versions; 20.4 versions prior to 20.4R3; 21.1 versions prior to 21.1R2. This issue does not affect 18.4 versions prior to 18.4R1 on SRX Series. This issue does not affect Junos OS Evolved. | |||||
CVE-2021-0275 | 1 Juniper | 24 Ex2300, Ex2300-c, Ex3400 and 21 more | 2024-11-21 | 9.3 HIGH | 8.8 HIGH |
A Cross-site Scripting (XSS) vulnerability in J-Web on Juniper Networks Junos OS allows an attacker to target another user's session thereby gaining access to the users session. The other user session must be active for the attack to succeed. Once successful, the attacker has the same privileges as the user. If the user has root privileges, the attacker may be able to gain full control of the device. This issue affects: Juniper Networks Junos OS: 12.3 versions prior to 12.3R12-S15 on EX Series; 12.3X48 versions prior to 12.3X48-D95 on SRX Series; 15.1 versions prior to 15.1R7-S6 on EX Series; 15.1X49 versions prior to 15.1X49-D200 on SRX Series; 16.1 versions prior to 16.1R7-S7; 16.2 versions prior to 16.2R2-S11, 16.2R3; 17.1 versions prior to 17.1R2-S11, 17.1R3-S2; 17.2 versions prior to 17.2R3-S3; 17.3 versions prior to 17.3R2-S5, 17.3R3-S7; 17.4 versions prior to 17.4R2-S9, 17.4R3; 18.1 versions prior to 18.1R3-S9; 18.2 versions prior to 18.2R2-S7, 18.2R3-S3; 18.3 versions prior to 18.3R1-S7, 18.3R2-S3, 18.3R3-S1; 18.4 versions prior to 18.4R1-S6, 18.4R2-S4, 18.4R3; 19.1 versions prior to 19.1R2-S1, 19.1R3; 19.2 versions prior to 19.2R1-S3, 19.2R2; 19.3 versions prior to 19.3R2. | |||||
CVE-2021-0261 | 1 Juniper | 23 Ex2300, Ex2300-c, Ex3400 and 20 more | 2024-11-21 | 5.0 MEDIUM | 7.5 HIGH |
A vulnerability in the HTTP/HTTPS service used by J-Web, Web Authentication, Dynamic-VPN (DVPN), Firewall Authentication Pass-Through with Web-Redirect, and Captive Portal allows an unauthenticated attacker to cause an extended Denial of Service (DoS) for these services by sending a high number of specific requests. This issue affects: Juniper Networks Junos OS 12.3 versions prior to 12.3R12-S17 on EX Series; 12.3X48 versions prior to 12.3X48-D105 on SRX Series; 15.1 versions prior to 15.1R7-S8; 15.1X49 versions prior to 15.1X49-D230 on SRX Series; 16.1 versions prior to 16.1R7-S8; 17.4 versions prior to 17.4R2-S12, 17.4R3-S3; 18.1 versions prior to 18.1R3-S11; 18.2 versions prior to 18.2R3-S6; 18.3 versions prior to 18.3R2-S4, 18.3R3-S3; 18.4 versions prior to 18.4R2-S5, 18.4R3-S4; 19.1 versions prior to 19.1R2-S2, 19.1R3-S2; 19.2 versions prior to 19.2R1-S5, 19.2R3; 19.3 versions prior to 19.3R2-S4, 19.3R3; 19.4 versions prior to 19.4R1-S3, 19.4R2-S2, 19.4R3; 20.1 versions prior to 20.1R1-S3, 20.1R2; 20.2 versions prior to 20.2R1-S1, 20.2R2. | |||||
CVE-2021-0249 | 1 Juniper | 14 Junos, Srx1500, Srx300 and 11 more | 2024-11-21 | 10.0 HIGH | 8.1 HIGH |
On SRX Series devices configured with UTM services a buffer overflow vulnerability in the Packet Forwarding Engine (PFE) of Juniper Networks Junos OS may allow an attacker to arbitrarily execute code or commands on the target to take over or otherwise impact the device by sending crafted packets to or through the device. This issue affects: Juniper Networks Junos OS on SRX Series: 15.1X49 versions prior to 15.1X49-D190; 17.4 versions prior to 17.4R2-S9; 17.4R3 and later versions prior to 18.1R3-S9; 18.2 versions prior to 18.2R3-S1; 18.3 versions prior to 18.3R2-S3, 18.3R3; 18.4 versions prior to 18.4R2-S3, 18.4R3; 19.1 versions prior to 19.1R1-S4, 19.1R2; 19.2 versions prior to 19.2R1-S1, 19.2R2. An indicator of compromise can be the following text in the UTM log: RT_UTM: AV_FILE_NOT_SCANNED_PASSED_MT: | |||||
CVE-2021-0246 | 1 Juniper | 8 Junos, Srx1500, Srx4100 and 5 more | 2024-11-21 | 4.6 MEDIUM | 7.3 HIGH |
On SRX1500, SRX4100, SRX4200, SRX4600, SRX5000 Series with SPC2/SPC3, devices using tenant services on Juniper Networks Junos OS, due to incorrect default permissions assigned to tenant system administrators a tenant system administrator may inadvertently send their network traffic to one or more tenants while concurrently modifying the overall device system traffic management, affecting all tenants and the service provider. Further, a tenant may inadvertently receive traffic from another tenant. This issue affects: Juniper Networks Junos OS 18.3 version 18.3R1 and later versions on SRX1500, SRX4100, SRX4200, SRX4600, SRX5000 Series with SPC2; 18.3 versions prior to 18.3R3 on SRX1500, SRX4100, SRX4200, SRX4600, SRX5000 Series with SPC2; 18.4 versions prior to 18.4R2 on SRX1500, SRX4100, SRX4200, SRX4600, SRX5000 Series with SPC2/SPC3; 19.1 versions prior to 19.1R2 on SRX1500, SRX4100, SRX4200, SRX4600, SRX5000 Series with SPC2/SPC3. This issue does not affect: Juniper Networks Junos OS versions prior to 18.3R1. | |||||
CVE-2021-0244 | 1 Juniper | 23 Ex2300, Ex2300-c, Ex3400 and 20 more | 2024-11-21 | 4.3 MEDIUM | 7.4 HIGH |
A signal handler race condition exists in the Layer 2 Address Learning Daemon (L2ALD) of Juniper Networks Junos OS due to the absence of a specific protection mechanism to avoid a race condition which may allow an attacker to bypass the storm-control feature on devices. This issue is a corner case and only occurs during specific actions taken by an administrator of a device under certain specifics actions which triggers the event. The event occurs less frequently on devices which are not configured with Virtual Chassis configurations, and more frequently on devices configured in Virtual Chassis configurations. This issue is not specific to any particular Junos OS platform. An Indicator of Compromise (IoC) may be seen by reviewing log files for the following error message seen by executing the following show statement: show log messages | grep storm Result to look for: /kernel: GENCFG: op 58 (Storm Control Blob) failed; err 1 (Unknown) This issue affects: Juniper Networks Junos OS: 14.1X53 versions prior to 14.1X53-D49 on EX Series; 15.1 versions prior to 15.1R7-S6; 15.1X49 versions prior to 15.1X49-D191, 15.1X49-D200 on SRX Series; 16.1 versions prior to 16.1R7-S7; 16.2 versions prior to 16.2R2-S11, 16.2R3; 17.1 versions prior to 17.1R2-S11, 17.1R3; 17.2 versions prior to 17.2R2-S8, 17.2R3-S3; 17.3 versions prior to 17.3R2-S5, 17.3R3-S7; 17.4 versions prior to 17.4R2-S9, 17.4R3; 18.1 versions prior to 18.1R3-S5; 18.2 versions prior to 18.2R2-S6, 18.2R3; 18.3 versions prior to 18.3R1-S7, 18.3R2-S3, 18.3R3; 18.4 versions prior to 18.4R1-S5, 18.4R2; 19.1 versions prior to 19.1R1-S4, 19.1R2. | |||||
CVE-2021-0235 | 1 Juniper | 6 Junos, Srx1500, Srx4100 and 3 more | 2024-11-21 | 4.6 MEDIUM | 7.3 HIGH |
On SRX1500, SRX4100, SRX4200, SRX4600, SRX5000 Series with SPC2/SPC3, vSRX Series devices using tenant services on Juniper Networks Junos OS, due to incorrect permission scheme assigned to tenant system administrators, a tenant system administrator may inadvertently send their network traffic to one or more tenants while concurrently modifying the overall device system traffic management, affecting all tenants and the service provider. Further, a tenant may inadvertently receive traffic from another tenant. This issue affects: Juniper Networks Junos OS 18.3 version 18.3R1 and later versions on SRX1500, SRX4100, SRX4200, SRX4600, SRX5000 Series with SPC2; 18.4 version 18.4R1 and later versions on SRX1500, SRX4100, SRX4200, SRX4600, SRX5000 Series with SPC2/SPC3; 19.1 versions 19.1R1 and later versions on SRX1500, SRX4100, SRX4200, SRX4600, SRX5000 Series with SPC2/SPC3; 19.2 versions prior to 19.2R1-S6, 19.2R3-S2 on SRX1500, SRX4100, SRX4200, SRX4600, SRX5000 Series with SPC2/SPC3; 19.3 versions prior to 19.3R3-S2 on SRX1500, SRX4100, SRX4200, SRX4600, SRX5000 Series with SPC2/SPC3; 19.4 versions prior to 19.4R2-S4, 19.4R3-S2 on SRX1500, SRX4100, SRX4200, SRX4600, SRX5000 Series with SPC2/SPC3; 20.1 versions prior to 20.1R2, 20.1R3 on SRX1500, SRX4100, SRX4200, SRX4600, SRX5000 Series with SPC2/SPC3 vSRX Series; 20.2 versions prior to 20.2R2-S1, 20.2R3 on SRX1500, SRX4100, SRX4200, SRX4600, SRX5000 Series with SPC2/SPC3 vSRX Series; 20.3 versions prior to 20.3R1-S2, 20.3R2 on SRX1500, SRX4100, SRX4200, SRX4600, SRX5000 Series with SPC2/SPC3 vSRX Series; 20.4 versions prior to 20.4R1, 20.4R2 on SRX1500, SRX4100, SRX4200, SRX4600, SRX5000 Series with SPC2/SPC3 vSRX Series. This issue does not affect Juniper Networks Junos OS versions prior to 18.3R1. | |||||
CVE-2021-0231 | 1 Juniper | 15 Junos, Srx1500, Srx300 and 12 more | 2024-11-21 | 6.8 MEDIUM | 6.5 MEDIUM |
A path traversal vulnerability in the Juniper Networks SRX and vSRX Series may allow an authenticated J-web user to read sensitive system files. This issue affects Juniper Networks Junos OS on SRX and vSRX Series: 19.3 versions prior to 19.3R2-S6, 19.3R3-S1; 19.4 versions prior to 19.4R2-S4, 19.4R3; 20.1 versions prior to 20.1R1-S4, 20.1R2; 20.2 versions prior to 20.2R1-S3, 20.2R2; This issue does not affect Juniper Networks Junos OS versions prior to 19.3R1. | |||||
CVE-2021-0230 | 1 Juniper | 27 Junos, Srx100, Srx110 and 24 more | 2024-11-21 | 5.0 MEDIUM | 7.5 HIGH |
On Juniper Networks SRX Series devices with link aggregation (lag) configured, executing any operation that fetches Aggregated Ethernet (AE) interface statistics, including but not limited to SNMP GET requests, causes a slow kernel memory leak. If all the available memory is consumed, the traffic will be impacted and a reboot might be required. The following log can be seen if this issue happens. /kernel: rt_pfe_veto: Memory over consumed. Op 1 err 12, rtsm_id 0:-1, msg type 72 /kernel: rt_pfe_veto: free kmem_map memory = (20770816) curproc = kmd An administrator can use the following CLI command to monitor the status of memory consumption (ifstat bucket): user@device > show system virtual-memory no-forwarding | match ifstat Type InUse MemUse HighUse Limit Requests Limit Limit Size(s) ifstat 2588977 162708K - 19633958 <<<< user@device > show system virtual-memory no-forwarding | match ifstat Type InUse MemUse HighUse Limit Requests Limit Limit Size(s) ifstat 3021629 189749K - 22914415 <<<< This issue affects Juniper Networks Junos OS on SRX Series: 17.1 versions 17.1R3 and above prior to 17.3R3-S11; 17.4 versions prior to 17.4R3-S5; 18.2 versions prior to 18.2R3-S7, 18.2R3-S8; 18.3 versions prior to 18.3R3-S4; 18.4 versions prior to 18.4R2-S7, 18.4R3-S6; 19.1 versions prior to 19.1R3-S4; 19.2 versions prior to 19.2R1-S6; 19.3 versions prior to 19.3R3-S1; 19.4 versions prior to 19.4R3-S1; 20.1 versions prior to 20.1R2, 20.1R3; 20.2 versions prior to 20.2R2-S2, 20.2R3; 20.3 versions prior to 20.3R1-S2, 20.3R2. This issue does not affect Juniper Networks Junos OS prior to 17.1R3. | |||||
CVE-2021-0227 | 1 Juniper | 22 Junos, Srx100, Srx110 and 19 more | 2024-11-21 | 5.0 MEDIUM | 7.5 HIGH |
An improper restriction of operations within the bounds of a memory buffer vulnerability in Juniper Networks Junos OS J-Web on SRX Series devices allows an attacker to cause Denial of Service (DoS) by sending certain crafted HTTP packets. Continued receipt and processing of these packets will create a sustained Denial of Service (DoS) condition. When this issue occurs, web-management, NTP daemon (ntpd) and Layer 2 Control Protocol process (L2CPD) daemons might crash. This issue affects Juniper Networks Junos OS on SRX Series: 17.3 versions prior to 17.3R3-S9; 17.4 versions prior to 17.4R2-S11, 17.4R3-S2; 18.2 versions prior to 18.2R3-S5; 18.3 versions prior to 18.3R2-S4, 18.3R3-S3; 18.4 versions prior to 18.4R2-S5, 18.4R3-S4; 19.1 versions prior to 19.1R3-S2; 19.2 versions prior to 19.2R1-S5, 19.2R3; 19.3 versions prior to 19.3R3; 19.4 versions prior to 19.4R2-S1, 19.4R3; 20.1 versions prior to 20.1R1-S2, 20.1R2; | |||||
CVE-2021-0211 | 1 Juniper | 87 Ex2200, Ex2200-c, Ex2200-vc and 84 more | 2024-11-21 | 6.4 MEDIUM | 10.0 CRITICAL |
An improper check for unusual or exceptional conditions in Juniper Networks Junos OS and Junos OS Evolved Routing Protocol Daemon (RPD) service allows an attacker to send a valid BGP FlowSpec message thereby causing an unexpected change in the route advertisements within the BGP FlowSpec domain leading to disruptions in network traffic causing a Denial of Service (DoS) condition. Continued receipt of these update messages will cause a sustained Denial of Service condition. This issue affects Juniper Networks: Junos OS: All versions prior to 17.3R3-S10 with the exceptions of 15.1X49-D240 on SRX Series and 15.1R7-S8 on EX Series; 17.3 versions prior to 17.3R3-S10; 17.4 versions prior to 17.4R2-S12, 17.4R3-S4; 18.1 versions prior to 18.1R3-S12; 18.2 versions prior to 18.2R2-S8, 18.2R3-S6; 18.3 versions prior to 18.3R3-S4; 18.4 versions prior to 18.4R1-S8, 18.4R2-S6, 18.4R3-S6; 19.1 versions prior to 19.1R1-S6, 19.1R2-S2, 19.1R3-S3; 19.2 versions prior to 19.2R3-S1; 19.3 versions prior to 19.3R2-S5, 19.3R3-S1; 19.4 versions prior to 19.4R1-S3, 19.4R2-S3, 19.4R3; 20.1 versions prior to 20.1R2; 20.2 versions prior to 20.2R1-S3 20.2R2; 20.3 versions prior to 20.3R1-S1, 20.3R2. Junos OS Evolved: All versions prior to 20.3R1-S1-EVO, 20.3R2-EVO. | |||||
CVE-2021-0208 | 1 Juniper | 15 Junos, Junos Os Evolved, Srx1500 and 12 more | 2024-11-21 | 3.3 LOW | 8.8 HIGH |
An improper input validation vulnerability in the Routing Protocol Daemon (RPD) service of Juniper Networks Junos OS allows an attacker to send a malformed RSVP packet when bidirectional LSPs are in use, which when received by an egress router crashes the RPD causing a Denial of Service (DoS) condition. Continued receipt of the packet will sustain the Denial of Service. This issue affects: Juniper Networks Junos OS: All versions prior to 17.3R3-S10 except 15.1X49-D240 for SRX series; 17.4 versions prior to 17.4R3-S2; 18.1 versions prior to 18.1R3-S10; 18.2 versions prior to 18.2R2-S7, 18.2R3-S4; 18.3 versions prior to 18.3R3-S2; 18.4 versions prior to 18.4R1-S8, 18.4R2-S6, 18.4R3-S2; 19.1 versions prior to 19.1R1-S5, 19.1R3-S3; 19.2 versions prior to 19.2R3; 19.3 versions prior to 19.3R2-S5, 19.3R3; 19.4 versions prior to 19.4R2-S2, 19.4R3-S1; 20.1 versions prior to 20.1R1-S4, 20.1R2; 15.1X49 versions prior to 15.1X49-D240 on SRX Series. Juniper Networks Junos OS Evolved: 19.3 versions prior to 19.3R2-S5-EVO; 19.4 versions prior to 19.4R2-S2-EVO; 20.1 versions prior to 20.1R1-S4-EVO. | |||||
CVE-2021-0206 | 1 Juniper | 17 Junos, Nfx150, Nfx250 and 14 more | 2024-11-21 | 5.0 MEDIUM | 7.5 HIGH |
A NULL Pointer Dereference vulnerability in Juniper Networks Junos OS allows an attacker to send a specific packet causing the packet forwarding engine (PFE) to crash and restart, resulting in a Denial of Service (DoS). By continuously sending these specific packets, an attacker can repeatedly disable the PFE causing a sustained Denial of Service (DoS). This issue only affects Juniper Networks NFX Series, SRX Series platforms when SSL Proxy is configured. This issue affects Juniper Networks Junos OS on NFX Series and SRX Series: 18.3 versions prior to 18.3R3-S4; 18.4 versions prior to 18.4R3-S1; 19.1 versions prior to 19.1R1-S6, 19.1R2-S2, 19.1R3; 19.2 versions prior to 19.2R1-S2, 19.2R2; 19.3 versions prior to 19.3R2. This issue does not affect Juniper Networks Junos OS versions on NFX Series and SRX Series prior to 18.3R1. | |||||
CVE-2020-1688 | 1 Juniper | 17 Junos, Nfx150, Nfx250 and 14 more | 2024-11-21 | 2.1 LOW | 6.5 MEDIUM |
On Juniper Networks SRX Series and NFX Series, a local authenticated user with access to the shell may obtain the Web API service private key that is used to provide encrypted communication between the Juniper device and the authenticator services. Exploitation of this vulnerability may allow an attacker to decrypt the communications between the Juniper device and the authenticator service. This Web API service is used for authentication services such as the Juniper Identity Management Service, used to obtain user identity for Integrated User Firewall feature, or the integrated ClearPass authentication and enforcement feature. This issue affects Juniper Networks Junos OS on Networks SRX Series and NFX Series: 12.3X48 versions prior to 12.3X48-D105; 15.1X49 versions prior to 15.1X49-D190; 16.1 versions prior to 16.1R7-S8; 17.2 versions prior to 17.2R3-S4; 17.3 versions prior to 17.3R3-S8; 17.4 versions prior to 17.4R2-S11, 17.4R3; 18.1 versions prior to 18.1R3-S7; 18.2 versions prior to 18.2R3; 18.3 versions prior to 18.3R2-S4, 18.3R3; 18.4 versions prior to 18.4R1-S7, 18.4R2; 19.1 versions prior to 19.1R2; 19.2 versions prior to 19.2R1-S4, 19.2R2. | |||||
CVE-2020-1661 | 1 Juniper | 32 Ex2300, Ex2300-c, Ex3400 and 29 more | 2024-11-21 | 4.3 MEDIUM | 5.3 MEDIUM |
On Juniper Networks Junos OS devices configured as a DHCP forwarder, the Juniper Networks Dynamic Host Configuration Protocol Daemon (jdhcp) process might crash when receiving a malformed DHCP packet. This issue only affects devices configured as DHCP forwarder with forward-only option, that forward specified DHCP client packets, without creating a new subscriber session. The jdhcpd daemon automatically restarts without intervention, but continuous receipt of the malformed DHCP packet will repeatedly crash jdhcpd, leading to an extended Denial of Service (DoS) condition. This issue can be triggered only by DHCPv4, it cannot be triggered by DHCPv6. This issue affects Juniper Networks Junos OS: 12.3 versions prior to 12.3R12-S16; 12.3X48 versions prior to 12.3X48-D105 on SRX Series; 14.1X53 versions prior to 14.1X53-D60 on EX and QFX Series; 15.1 versions prior to 15.1R7-S7; 15.1X49 versions prior to 15.1X49-D221, 15.1X49-D230 on SRX Series; 15.1X53 versions prior to 15.1X53-D593 on EX2300/EX3400; 16.1 versions prior to 16.1R7-S5. | |||||
CVE-2020-1634 | 1 Juniper | 10 Junos, Srx1500, Srx300 and 7 more | 2024-11-21 | 4.3 MEDIUM | 7.5 HIGH |
On High-End SRX Series devices, in specific configurations and when specific networking events or operator actions occur, an SPC receiving genuine multicast traffic may core. Subsequently, all FPCs in a chassis may reset causing a Denial of Service. This issue affects both IPv4 and IPv6. This issue affects: Juniper Networks Junos OS 12.3X48 version 12.3X48-D80 and later versions prior to 12.3X48-D95 on High-End SRX Series. This issue does not affect Branch SRX Series devices. | |||||
CVE-2020-1613 | 1 Juniper | 46 Ex2300, Ex2300-c, Ex3400 and 43 more | 2024-11-21 | 5.0 MEDIUM | 8.6 HIGH |
A vulnerability in the BGP FlowSpec implementation may cause a Juniper Networks Junos OS device to terminate an established BGP session upon receiving a specific BGP FlowSpec advertisement. The BGP NOTIFICATION message that terminates an established BGP session is sent toward the peer device that originally sent the specific BGP FlowSpec advertisement. This specific BGP FlowSpec advertisement received from a BGP peer might get propagated from a Junos OS device running the fixed release to another device that is vulnerable causing BGP session termination downstream. This issue affects IPv4 and IPv6 BGP FlowSpec deployment. This issue affects Juniper Networks Junos OS: 12.3; 12.3X48 on SRX Series; 14.1X53 on EX and QFX Series; 15.1 versions prior to 15.1R7-S5; 15.1F versions prior to 15.1F6-S13; 15.1X49 versions prior to 15.1X49-D180 on SRX Series; 15.1X53 versions prior to 15.1X53-D238 on QFX5200/QFX5110; 15.1X53 versions prior to 15.1X53-D497 on NFX Series; 15.1X53 versions prior to 15.1X53-D592 on EX2300/EX3400; 16.1 versions prior to 16.1R7-S7; 17.1 versions prior to 17.1R2-S12, 17.1R3; 17.2 versions prior to 17.2R2-S7, 17.2R3; 17.2X75 versions prior to 17.2X75-D102, 17.2X75-D110, 17.2X75-D44; 17.3 versions prior to 17.3R2-S5, 17.3R3-S5; 17.4 versions prior to 17.4R1-S8, 17.4R2; 18.1 versions prior to 18.1R2-S4, 18.1R3; 18.2X75 versions prior to 18.2X75-D20. | |||||
CVE-2020-1607 | 1 Juniper | 44 Ex2300, Ex2300-c, Ex3400 and 41 more | 2024-11-21 | 4.3 MEDIUM | 7.5 HIGH |
Insufficient Cross-Site Scripting (XSS) protection in J-Web may potentially allow a remote attacker to inject web script or HTML, hijack the target user's J-Web session and perform administrative actions on the Junos device as the targeted user. This issue affects Juniper Networks Junos OS 12.3 versions prior to 12.3R12-S15; 12.3X48 versions prior to 12.3X48-D86, 12.3X48-D90 on SRX Series; 14.1X53 versions prior to 14.1X53-D51 on EX and QFX Series; 15.1F6 versions prior to 15.1F6-S13; 15.1 versions prior to 15.1R7-S5; 15.1X49 versions prior to 15.1X49-D181, 15.1X49-D190 on SRX Series; 15.1X53 versions prior to 15.1X53-D238 on QFX5200/QFX5110 Series; 15.1X53 versions prior to 15.1X53-D592 on EX2300/EX3400 Series; 16.1 versions prior to 16.1R4-S13, 16.1R7-S5; 16.2 versions prior to 16.2R2-S10; 17.1 versions prior to 17.1R2-S11, 17.1R3-S1; 17.2 versions prior to 17.2R1-S9, 17.2R3-S2; 17.3 versions prior to 17.3R2-S5, 17.3R3-S5; 17.4 versions prior to 17.4R2-S6, 17.4R3; 18.1 versions prior to 18.1R3-S7; 18.2 versions prior to 18.2R2-S5, 18.2R3; 18.3 versions prior to 18.3R1-S6, 18.3R2-S1, 18.3R3; 18.4 versions prior to 18.4R1-S5, 18.4R2; 19.1 versions prior to 19.1R1-S2, 19.1R2. | |||||
CVE-2020-1606 | 1 Juniper | 24 Junos, Qfx5110, Qfx5200 and 21 more | 2024-11-21 | 6.5 MEDIUM | 5.4 MEDIUM |
A path traversal vulnerability in the Juniper Networks Junos OS device may allow an authenticated J-web user to read files with 'world' readable permission and delete files with 'world' writeable permission. This issue does not affect system files that can be accessed only by root user. This issue affects Juniper Networks Junos OS: 12.3 versions prior to 12.3R12-S13; 12.3X48 versions prior to 12.3X48-D85 on SRX Series; 14.1X53 versions prior to 14.1X53-D51; 15.1F6 versions prior to 15.1F6-S13; 15.1 versions prior to 15.1R7-S5; 15.1X49 versions prior to 15.1X49-D180 on SRX Series; 15.1X53 versions prior to 15.1X53-D238 on QFX5200/QFX5110 Series; 16.1 versions prior to 16.1R4-S13, 16.1R7-S5; 16.2 versions prior to 16.2R2-S10; 17.1 versions prior to 17.1R3-S1; 17.2 versions prior to 17.2R1-S9, 17.2R3-S2; 17.3 versions prior to 17.3R2-S5, 17.3R3-S5; 17.4 versions prior to 17.4R2-S9, 17.4R3; 18.1 versions prior to 18.1R3-S8; 18.2 versions prior to 18.2R3; 18.3 versions prior to 18.3R2-S3, 18.3R3; 18.4 versions prior to 18.4R2; 19.1 versions prior to 19.1R1-S4, 19.1R2. |